Dislodgement of Two Stents in One Patient during Percutaneous Coronary Intervention
Soonchunhyang Medical Science
;
: 26-28, 2013.
Artigo
em Inglês
| WPRIM
| ID: wpr-8458
ABSTRACT
Coronary stent loss is a rare but serious complication during interventional cardiology. This complication occurs not only in the intracoronary area but also in the extracoronary area, such as the aortic root or the left ventricle. An 83-year-old man with stable angina had a stent inserted into a heavy calcific left anterior descending artery. The stent was lost twice during the procedure. The first stent was dislodged from the left main coronary artery to the proximal left anterior descending artery, and the second stent migrated to the aortic root following separation from the balloon. We successfully redeployed the first stent at the dislodged site and retrieved the second stent using a goose-neck snare after moving the stent to the descending aorta. These steps circumvented the need for the patient to undergo emergency cardiovascular surgery.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Aorta Torácica
/
Artérias
/
Cardiologia
/
Stents
/
Vasos Coronários
/
Emergências
/
Proteínas SNARE
/
Angina Estável
/
Intervenção Coronária Percutânea
/
Ventrículos do Coração
Limite:
Humanos
Idioma:
Inglês
Revista:
Soonchunhyang Medical Science
Ano de publicação:
2013
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS