Your browser doesn't support javascript.
loading
Biomechanical comparison study of two ultra-strong sutures in repair of Achilles tendon via panda rope bridge technique / 中国修复重建外科杂志
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1147-1150, 2019.
Artigo em Chinês | WPRIM | ID: wpr-856486
ABSTRACT

Objective:

To compare the biomechanical properties of two ultra-strong sutures and suturing methods in panda rope bridge technique (PRBT) application, and provide guidance for clinical selection of suture threads and suture methods.

Methods:

Forty Achilles tendons from bulls were randomly divided into 4 groups ( n=10) and transected at the 4 cm proximal to the tendon insertion. Groups A and B used Ethibond sutures (USP 5), the proximal end was fixed at the myotendious junction with Krackow sutures and the distal end was fixed through a calcaneus canal. Groups A and B had 4 and 8 threads through the stump plane, respectively. Groups C and D used Ultrabraid sutures (USP 2), the proximal end was fixed at the myotendious junction with Krackow sutures and the distal end was fixed in the calcaneus with two anchors. Groups C and D had 4 and 8 threads through the stump plane, respectively. The dynamic tensile forces of 20-100, 20-200, 20-300, and 20-400 N were tested respectively by using a dynamic tensile testing machine at 0.5 Hz for 250 cycles. After each stage of testing, the gap between stumps was measured with a caliper and the type of suture failure was recorded.

Results:

After dynamic tensile forces of 20-100 N and 20-200 N, the gaps of the four groups arranged from small to large were groups D, B, C, and A. The differences between groups A and B and groups C and D were significant ( P0.05). After dynamic tensile forces of 20-400 N, the suture retention rates of groups A, B, C, and D were 0, 50%, 0, and 70%, respectively. There were significant differences between groups A and B and groups C and D ( P<0.05).

Conclusion:

Repairing Achilles tendon rupture via PRBT with 8 ultra-strong sutures through the stump plane can meet the mechanical requirements for walking by using ankle boots and heel pads in the early accelerated rehabilitation after operation.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Chinese Journal of Reparative and Reconstructive Surgery Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Chinese Journal of Reparative and Reconstructive Surgery Ano de publicação: 2019 Tipo de documento: Artigo