Progress of monitoring methods and preventions of disorder of blood supplying of expanded flaps / 中国修复重建外科杂志
Chinese Journal of Reparative and Reconstructive Surgery
;
(12): 118-124, 2018.
Artigo
em Chinês
| WPRIM
| ID: wpr-856853
ABSTRACT
Results:
Handheld Doppler, digital subtraction angiography, computer tomographic angiography, magnetic resonance angiography, and fluorescein angiography can be used as reliable preoperative imaging methods in designing expanded flaps with rich blood supply. Several techniques can be used for monitoring the blood supply of expanded flaps during the early postoperative period including traditional monitoring via physical examination, monitoring via dynamic infrared thermography, near-infrared spectroscopy tissue oximeter, external and implantable Doppler, and more recently developed diffuse correlation spectroscopy. Surgical delay, bloodletting, leech therapy, hyperbaric oxygen, and so on can decrease the risk of necrosis in expanded flaps.