Application value of high-frequency ultrasound in diagnosis of finger extensor tendon olisthy / 中国医学影像技术
Chinese Journal of Medical Imaging Technology
;
(12): 1389-1391, 2019.
Artigo
em Chinês
| WPRIM
| ID: wpr-861248
ABSTRACT
Objective:
To explore the application value of high-frequency ultrasound in diagnosis of finger extensor tendon olisthy.Methods:
A total of 32 dorsal trauma in metacarpophalangeal joint patients with clinically suspected finger extensor tendon olisthy underwent high-frequency ultrasound. Olisthy in finger extensor tendon and causes of injuries were observed, and the results were compared with those of surgical operations.Results:
Among all 32 cases, surgery treatment was performed in 25 patients, including 7 patients of partial olisthy in extensor tendon and 18 patients of complete olisthy, while 7 patients were found without olisthy (only tendon hood injury) and were followed up for observation. Utrasound missed 1 case with complete olisthy in finger extensor tendon and misdiagnosed 2 cases of complete olisthy as partial olisthy. The consistency of ultrasound examination and surgery results was well (Kappa=0.85, P<0.01).Conclusion:
Ultrasound can show tendon hood tear and finger extensor tendon olisthy and judge the injury degree through dynamic observation, therefore providing important evidences for clinical treatment.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Tipo de estudo:
Estudo diagnóstico
Idioma:
Chinês
Revista:
Chinese Journal of Medical Imaging Technology
Ano de publicação:
2019
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS