Your browser doesn't support javascript.
loading
Clinical study of pulmonary embolism CT imaging using the third generation dual-source CT with low tube voltage and low contrast dosage / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 712-716, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868497
ABSTRACT

Objective:

To investigate the clinical value of third-generation dual-source CT with high pitch, 70 kV combined with 16 ml contrast agent in low radiation dose imaging of pulmonary embolism (PE).

Methods:

Eighty-three patients with suspected PE underwent CT pulmonary angiography were randomly divided into two groups group A with 36 cases, 100 kV, 1.0 pitch, and 60 ml contrast agent; group B with 47 cases, 70 kV, 2.2 pitch, and 16 ml contrast agent. The volume CT dose index and dose length product of the two groups were recorded to calculate the effective dose E, and the CT values of enhanced pulmonary arteries, background noise, and muscles values were recorded to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The overall image quality and the beam-hardening artifact of superior vena cava were subjectively evaluated on a 3-point scale.

Results:

There were no significant differences in gender, age, height, weight, BMI, proportion of PE, and CT values of enhanced pulmonary arteries at all levels ( P>0.05). The value E of group B was (0.76±0.13) mSv, significantly lower than that in group A [(1.91±0.54) mSv, Z=-5.23, P<0.001]. Although background noise of group B was significantly higher than that of group A ( Z=-4.99, P <0.001), SNR and CNR values of group B were significantly lower than those of group A ( Z=-4.56, -4.48, P<0.001), there was no statistically significant difference in the overall image quality scores between the two groups ( P>0.05). The beam-hardening artifact caused by superior vena cava in group B was significantly lower than that in group A ( Z=-5.15, P <0.001).

Conclusions:

The third generation dual-source CT with high pitch, 70 kV combined with 16 ml contrast agent can significantly reduce the interference of contrast agent beam-hardening artifact on the right and right superior pulmonary arteries to ensure the diagnostic image quality of PE, and effectively reduce radiation dose by 60% and total volume of contrast agent by 73%.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2020 Tipo de documento: Artigo