Your browser doesn't support javascript.
loading
A review of intercomparison of measurement results by gamma-ray spectrometry in three laboratories in China and Japan / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 758-764, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868523
ABSTRACT

Objective:

To improve the radionuclide measurement technology by γ-spectrometry throuth a review of the intercomparisons between China and Japan results over the past 20 years.

Methods:

Before the beginning of each intercomparison, one of participating laboratories was agreed to be responsible for preparing the samples for the intercomparison. By intercomparison of the measurement results arnong the laboratories some potential problems during the sample pre-trement or analysis were found and solved.

Results:

The intercomparisons had been carried out for 11 times over the past 20 years. Totally 290 measured and analyzed results had been obtained from 20 samples of six categories. The proportion 95.5% of measurement results were in agreement with each other within the deviation range.

Conclusions:

The measuring and analytical capability of the laboratories involved were tested. The intercomparisons also provide long-term quality assurance measures for the radionuclide measurement and analysis in each laboratory.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2020 Tipo de documento: Artigo