ABSTRACT

Objective:

To explore the effect of invalid reconstruction of proximal triangular structure on clinical failure of proximal femoral fractures treatment.

Methods:

A retrospective study of patients with femoral neck or intertrochanteric fractures postoperative failures from January 2013 to December 2018 was performed. Fifty-three patients including 26 males and 27 females (31 intertrochanteric fractures and 22 femoral neck fractures) met the inclusion criteria. The mean age of included patients was 55.13 years (range, 18-94 years). Fixation strategies included plate screws (18 cases), cannulated screws (13 cases) and intramedullary nails (22 cases). Medial side, the lateral side and the upper side were defined according to the law of mechanics based on the proximal femoral structure and statistical analysis of the failure factors of reconstruction of different sides were performed based on the imaging data of postoperative failure cases.

Results:

Nineteen of 53 patients were without medial side reconstruction, 4 cases without lateral side reconstruction, 21 cases without upper side reconstruction, 2 cases without medial or lateral side reconstruction and 7 cases were without medial or upper side reconstruction. Sixteen cases experienced loss of reduction, and 23 cases suffered from nonunion; excessive movement of fixation occurred in 12 cases, and fixation breakage occurred in 2 cases. Indicated by statistical analysis, it was invalid reconstruction of different sides that lead to surgical failure ( P=0.098). Revision strategy 5 cases were treated with plate-screw fixation, 1 with steel cable binding, 11 with hip replacement, 3 with internal fixation removal, 6 with intramedullary nail replacement, 21 with triangular reconstruction fixation, and 6 cases had not been followed up successfully.

Conclusion:

Invalid reconstruction of any side of the proximal triangular structure will cause instability of the proximal structure which can lead to the failure of fracture fixation during the treatment of proximal femoral fractures.