Your browser doesn't support javascript.
loading
PTV Margins for Prostate Treatments with an Endorectal Balloon / 대한방사선종양학회지
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 166-176, 2010.
Artigo em Inglês | WPRIM | ID: wpr-87887
ABSTRACT

PURPOSE:

To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. MATERIALS AND

METHODS:

Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual C++. A new method to determine prostate PTV margins with an ERB was developed by using the common method.

RESULTS:

The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors.

CONCLUSION:

The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próstata / Reto / Decúbito Dorsal / Radioterapia Conformacional / Eletrônica / Elétrons Limite: Humanos Idioma: Inglês Revista: The Journal of the Korean Society for Therapeutic Radiology and Oncology Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próstata / Reto / Decúbito Dorsal / Radioterapia Conformacional / Eletrônica / Elétrons Limite: Humanos Idioma: Inglês Revista: The Journal of the Korean Society for Therapeutic Radiology and Oncology Ano de publicação: 2010 Tipo de documento: Artigo