Your browser doesn't support javascript.
loading
Use of Continuous Glucose Monitoring (CGM) Technology in the Management of Type 2 Diabetes Mellitus in the Primary Care Setting: A Case Report
The Singapore Family Physician ; : 54-57, 2021.
Artigo em Inglês | WPRIM | ID: wpr-881363
ABSTRACT
@#This case report of a 30-year-old type 2 diabetic patient illustrates the advantages of using real-time continuous glucose monitoring (rt-CGM) in a primary care setting. The patient was successfully weaned off subcutaneous insulin injections over a period of two months and achieved even better time-in-range outcomes. The patient is empowered with more insight into his metabolic condition and is currently trying new techniques such as intermittent fasting to further improve his diabetes.

Buscar no Google
Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: The Singapore Family Physician Ano de publicação: 2021 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: The Singapore Family Physician Ano de publicação: 2021 Tipo de documento: Artigo