ABSTRACT
Objective:
To establish a specific and sensitive method using loop-mediated isothermal amplification for rapid screening of Salmonella.Methods:
The invA gene sequence of Salmonella was downloaded from GenBank. After homology comparison with DNAMAN software, amplification primers were designed in the conserved region, and a LAMP-LFD detection method was established. The reaction system was optimized, and the specificity and sensitivity of the method were verified.Results:
The sensitivity of this method to detect Salmonella DNA was up to 1.0×101 copies/μL. The positive rate of anal swabs was the same as that of fluorescent PCR. Meanwhile, LAMP-LFD was easy to operate and did not need expensive instruments. The detection result could be obtained within 30 minutes.Conclusion:
The LAMP-LFD method established in this study is rapid, simple, sensitive and specific, which is suitable for rapid screening of Salmonella.