Determination of N-methyl-2-pyrrolidone in workplace air by solvent desorption-gas chromatography / 中国职业医学
China Occupational Medicine ; (6): 229-232, 2019.
Article em Zh | WPRIM | ID: wpr-881785
Biblioteca responsável: WPRO
ABSTRACT
OBJECTIVE: To establish a method for determination of N-methyl-2-pyrrolidone(NMP) in workplace air by solvent desorption-gas chromatography. METHODS: NMP in the workplace air was collected with activated carbon tube and desorbed with methanol ∶dichloromethane(5 ∶95, V/V). After desorption, it was separated by capillary column separation, and detected by flame ionization detector. RESULTS: The good linear concentration of NMP was 0.51-4 108.00 mg/L. The correlation coefficient was 0.999 9. The detection limit was 0.08 mg/L(calculated by 3 times of standard deviation). The average desorption efficiency was 101.68%-103.44%. The within-run and between-run relative standard deviations were 1.94%-3.97% and 0.97%-2.26%, respectively. The sample could be stored at room temperature for at least 14 days. CONCLUSION: The developed method is suitable for the determination of NMP in workplace air.