Your browser doesn't support javascript.
loading
Dosimetry evaluation of navigation system-assisted and CT-guided seed implantation in the treatment of recurrent malignant pelvic tumors / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 50-55, 2021.
Artigo em Chinês | WPRIM | ID: wpr-884473
ABSTRACT

Objective:

To explore the accuracy of CT-guided 125I seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors by comparing pre-plan and intraoperative physical dosimetric parameters.

Methods:

This study involved 15 patients with recurrent malignant pelvic tumors who received CT-guided radioactive 125I seed implantation assisted by a navigation system and 3D-printing template in the Peking University Third Hospital from Dec 2018 to Feb 2020.Seven of the patients had cervical cancers, seven had rectal cancers, and one had prostate cancer.The median age was 55 years (34-84 years old). The prescription dose was 100-150 Gy.The pre-plan and post-implant data were compared, including the number of implanted seeds, implantation needle number, and some dosimetric parameters such as the minimum prescription doses delivered to 90% and 100% of target volume( D90, D100), mean percentages of volume receiving 100%, 150%, and 200% of the prescription doses( V100, V150, and V200), conformity index(CI), external index(EI), and homogeneity index(HI)of the target volume.

Results:

The median lesion volume was 29.20 cm 3, the median seed number was 54, and the median D90 was 150 Gy.The post-implant V150 was lower than pre-plan V150 (64.1% vs. 67.1%, t=2.937, P=0.011), and the post-implant mean HI was higher than pre-plan HI (32.01% vs. 26.68%, t=-2.950, P=0.011). There were no significant differences in other dosimetric parameters before and after seed implantation.

Conclusions:

With CT-guided radioactive seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors, the actual postoperative dose could meet the preoperative plan requirement, ensuring the accuracy and consistency of the dose delivered.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2021 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2021 Tipo de documento: Artigo