Your browser doesn't support javascript.
loading
A comparative evaluation of visual, refractive, and patient-reported outcomes of three diffractive trifocal intraocular lenses
Philippine Journal of Ophthalmology ; : 28-40, 2020.
Artigo em Inglês | WPRIM | ID: wpr-886266
ABSTRACT
@#

OBJECTIVE:

To compare the visual, refractive, and patient-reported outcomes of eyes implanted with one of 3 trifocal intraocular lenses (IOLs).

METHODS:

This is a cross-sectional, comparative, non-interventional study wherein subjects implanted with FineVision Micro F, AT LISA tri 839MP or AcrySof IQ PanOptix trifocal IOL after phacoemulsification were recruited. Manifest refraction, uncorrected and corrected visual acuity (VA) at distance, intermediate and near vision, contrast sensitivity, modulated transfer function (MTF) values and questionnaire answers were compared among the 3 groups using analysis of variance (ANOVA).

RESULTS:

Fifty-seven (57) eyes were included in the study 21 eyes with FineVision (group A), 21 eyes with LISA tri (group B), and 15 eyes with PanOptix IOL (group C). The post-operative mean manifest spherical equivalent was -0.01D, -0.07D, and 0.05D, respectively (p=0.083). Uncorrected distance VA and best-corrected distance VA were similar among the groups. Groups A and C had better uncorrected and corrected intermediate VA at 80 cm and at 60 cm compared to group B. Group A had significantly better uncorrected near visual acuity than groups B and C (p=0.032). Mesopic contrast sensitivity testing showed group C had higher contrast sensitivities without glare in at the spatial frequency of 6 CPD (p=0.038) and with glare at 3 CPD (p=0.039) and at 12 CPD (p=0.009). MTF average height analysis showed that the group A had significantly superior resolution in far targets compared to groups B and C (p=0.001). At near targets, groups A and C had better resolutions compared to group B (p=0.017). There was no significant difference in patient satisfaction for far, intermediate and near VA among the groups.

CONCLUSION:

Eyes implanted with any of the 3 trifocal IOL designs achieved excellent uncorrected and bestcorrected distance, intermediate and near vision. FineVision and PanOptix provided significantly better intermediate vision than LISA tri at both 80 cm and 60 cm testing distance. FineVision had better near visual outcomes than PanOptix and LISA tri. Patient satisfaction was high in all 3 trifocal IOLS
Assuntos

Buscar no Google
Índice: WPRIM (Pacífico Ocidental) Assunto principal: Visão Ocular / Lentes Intraoculares Idioma: Inglês Revista: Philippine Journal of Ophthalmology Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: WPRIM (Pacífico Ocidental) Assunto principal: Visão Ocular / Lentes Intraoculares Idioma: Inglês Revista: Philippine Journal of Ophthalmology Ano de publicação: 2020 Tipo de documento: Artigo