Paraplegia after Open Repair of Suprarenal Abdominal Aortic Aneurysm
Vascular Specialist International ; : 248-251, 2020.
Artigo em Inglês | WPRIM | ID: wpr-904180
ABSTRACT
Spinal cord ischemia after open repair of abdominal aortic aneurysm (AAA) is an unpredictable and devastating complication. We present a case report of a patient who developed paraplegia 6 hours after open repair of suprarenal AAA. A 74-yearold man presented with asymptomatic 5.5-cm suprarenal AAA, for which he underwent open repair under general anesthesia. The paraplegia was identified 6 hours after the operation. Postoperative magnetic resonance imaging showed T2 signal hyperintensity and swelling of the spinal cord, which were consistent findings with subacute spinal cord infarction. Although intravenous steroid was administered and lumbar cerebral spinal fluid drainage was instituted, his neurological outcome did not improve. He was discharged after vigorous rehabilitation but still has paraplegia and requires wheelchair for ambulation.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo prognóstico Idioma: Inglês Revista: Vascular Specialist International Ano de publicação: 2020 Tipo de documento: Artigo