PURPOSE:
To compare the diagnostic accuracy and complication rates of fluoroscopy-guided percutaneous transthoracic fine needle aspiration biopsy (FNAB) and core biopsy (CB). MATERIALS ANDMETHODS:
Ninety-one fluoroscopy-guided lung biopsies were performed in 86 patients using a 22-gauge fine needle (n=52) or a 21-gauge automated cutting needle (n=39). The size of pulmonary lesions were 1-9 cm. Histologic diagnosis rates and complications rates of the two groups were compared.RESULTS:
The overall sensitivity of FNAB was 98% (51/52) which was higher than that of CB 89.7% (35/39) (p=0.160, Fisher? exact test). For the diagnosis of malignancy, sensitivities of FNAB and CB were 97.2% (35/36) and 89.7% (26/29), respectively (p= 0.316). For the diagnosis of benignancy, sensitivities of FNAB and CB were 100% (16/16) and 90% (9/10), respectively (p=0.384). The specific histologic diagnosis rate of CB was 80% (8/10) in benignancy, which was higher than that of FNAB 56% (9/16) (p=0.398). The pneumothorax rates were 7.7% (4/52) for FNAB and 15.4% (6/39) for CB (p=0.316).CONCLUSION:
Although not statistically significant, a higher overall sensitivity was found in fluoroscopy-guided FNAB in the diagnosis of both malignancy and benignancy, and FNAB also achieved lower complication rates. More specific histologic diagnoses were obtained with CB.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Pneumotórax
/
Biópsia
/
Biópsia por Agulha Fina
/
Diagnóstico
/
Pulmão
/
Neoplasias Pulmonares
/
Agulhas
Tipo de estudo:
Estudo diagnóstico
Limite:
Humanos
Idioma:
Inglês
Revista:
Journal of the Korean Radiological Society
Ano de publicação:
2005
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS