Your browser doesn't support javascript.
loading
Dog-Bone double button in shoulder arthroscopic treatment of acute acromioclavicular dislocation / 中华创伤骨科杂志
Chinese Journal of Orthopaedic Trauma ; (12): 937-944, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910066
ABSTRACT

Objective:

To investigate the clinical efficacy of Dog-Bone double button in the treatment of acute acromioclavicular dislocation under shoulder arthroscopy.

Methods:

A retrospective analysis was conducted of the 20 patients with acute acromioclavicular dislocation who had been treated at Department of Sports Medicine, Northern Jiangsu People's Hospital of Jiangsu Province from November 2018 to December 2020 by Dog-Bone double button under shoulder arthroscopy. They were 11 males and 9 females, aged from 31 to 63 years. Recorded were their visual analogue scale (VAS), Constant-Murley shoulder function score and range of shoulder anteflexion at preoperation and the last follow-up, as well as complications and the X-ray parameters at one month postoperation and the last follow-up [including coracoclavicular distance (CCD), distance between the upper and lower Dog-Bone titanium plates (DDD), angle between the coracoid process tunnel and the tangent line of the superior clavicle (CTCA), and widths of the clavicle tunnel and the coracoid process tunnel].

Results:

The 20 patients were followed up for 6 to 12 months (average, 10.5 months). Their preoperative VAS score, Constant score, and range of shoulder anteflexion were 3.0 (3.0, 4.0), 57.0 (54.3, 61.5) and 130° (110°, 140°), which were significantly improved to 0 (0, 0.8), 90.0 (86.5, 91.0) and 170° (170°, 180°) at the last follow-up ( P<0.05). Their CCD, DDD, CTCA, and widths of the clavicle tunnel and the coracoid process at one month postoperation were (5.0±1.0) mm, (32.4±3.5) mm, 91.7° (88.5°, 104.9°), 3.0 (3.0, 3.0) mm and 3.0 (3.0, 3.0) mm, which were significantly improved to (6.3±1.3) mm, (32.8±3.7) mm, 84.8° (81.8°, 92.0°), 3.5 (3.4, 3.6) mm and 3.2 (3.1, 3.3) mm with the exception of DDD at one month postoperation ( P<0.05). The last follow-up observed postoperative reduction loss in only one patient.

Conclusion:

For acute acromioclavicular joint dislocation, the Dog-Bone fixation technique under shoulder arthroscopy can lead to fine surgical efficacy and patient satisfaction, because it has advantages of limited trauma, good functional recovery of the shoulder, and effective prevention of reduction loss.