Experimental Study on Puncture Mechanical Properties of Biomimetic Materials / 医用生物力学
Journal of Medical Biomechanics ; (6): E137-E141, 2022.
Artigo em Chinês | WPRIM | ID: wpr-920681
ABSTRACT
Objective To obtain a more suitable puncture method for venipuncture robot through experiments.Methods By using different puncture speeds and angles for biomimetic materials, the force-time curves by various puncture methods were obtained. Results During puncture process, with the increase of the puncture angle, a smaller puncture force was required. The faster puncture speed would lead to a larger puncture force. Conclusions The 40°-45° puncture angleand the 120-300 mm/min puncture speed should be used for designing the puncture method of venipuncture robot. The results provide references for selecting the puncture angle and speed of the venipuncture robot.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Medical Biomechanics Ano de publicação: 2022 Tipo de documento: Artigo