Comparison of the Clinical Diagnosis of Diabetic Macular Edema with Diagnosis by Retinal Thickness Analyzer
Journal of the Korean Ophthalmological Society
;
: 1299-1304, 2005.
Artigo
em Coreano
| WPRIM
| ID: wpr-92746
ABSTRACT
PURPOSE:
To evaluate the correlation between diabetic macular edema diagnosed with stereoscopic slit-lamp and retinal thickness analyzer (RTA).METHODS:
Diabetic macular edema diagnosed with stereoscopic slit-lamp was compared to indices of RTA in 50 eyes of 32 persons which were diagnosed clinically with diabetic retinopathy.RESULTS:
From stereoscopic slit-lamp results, diabetic macular edema was present in 39 of 50 eyes, and absent in 11 of 50. Foveal average thickness out of the RTA indices was 209.7+/-58.5 micrometer from observing diabetic macular edema clinically and 199.4+/-47.3 micrometer from not observing diabetic macular edema clinically. Statistically significant differences were found in average foveal thickness between the 2 groups (p=0.013).CONCLUSIONS:
RTA appears to serve as a useful and sensitive tool for the diagnosis of diabetic macular edema.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Retinaldeído
/
Edema Macular
/
Retinopatia Diabética
/
Diagnóstico
Tipo de estudo:
Estudo diagnóstico
Limite:
Humanos
Idioma:
Coreano
Revista:
Journal of the Korean Ophthalmological Society
Ano de publicação:
2005
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS