Your browser doesn't support javascript.
loading
Methods for synchronous detection of 14 mycotoxins in Pseudostellariae Radix and investigation on its contamination / 中国中药杂志
China Journal of Chinese Materia Medica ; (24): 628-634, 2022.
Artigo em Chinês | WPRIM | ID: wpr-927944
ABSTRACT
This study aimed to establish a method for synchronous detection of 14 mycotoxins in Pseudostellariae Radix and investigate its contamination with mycotoxins, so as to provide technical guidance for monitoring the quality of Chinese medicinal materials and medication safety. The sample was extracted with 80% acetonitrile in an oscillator for 1 h, purified using the modified QuEChERS purifying agent(0.1 g PSA + 0.3 g C_(18) + 0.3 g MgSO_4), and separated on a Waters HSS T3 chromatographic column(2.1 mm×100 mm, 1.8 μm). The gradient elution was carried out with 0.1% formic acid in water and acetonitrile, followed by the scanning in the multi-reaction monitoring(MRM) mode and the analysis of mycotoxin contamination in 26 Pseudostellariae Radix samples. The recovery rates of the established method were within the range of 82.17%-113.6%, with the RSD values less than 7% and the limits of quantification(LOQ) being 0.019-0.976 μg·kg~(-1). The detection rate of 14 mycotoxins in 26 batches of medicinal materials was 53.85%. The detection rate of sterigmatocystin(ST) was the highest, followed by those of zearalenone(ZEN), aflatoxin G_2(AFG_2), fumonisin B_1(FB_1), HT-2 toxin, and nivalenol(NIV). Their respective detection rates were 38.46%, 26.92%, 23.08%, 11.54%, 11.54%, and 7.69%, with the pollution ranges being 1.48-69.65, 0.11-31.05, 0.11-0.66, 0.28-0.83, 20.86-42.56, and 0.46-1.84 μg·kg~(-1), respectively. The established method for the detection of 14 mycotoxins is accurate, fast and reliable. The research results have very important practical significance for guiding the monitoring and prevention and control of exogenous fungal contamination of Chinese medicinal materials.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Contaminação de Alimentos / Contaminação de Medicamentos / Cromatografia Líquida de Alta Pressão / Raízes de Plantas / Aflatoxinas / Espectrometria de Massas em Tandem / Micotoxinas Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Contaminação de Alimentos / Contaminação de Medicamentos / Cromatografia Líquida de Alta Pressão / Raízes de Plantas / Aflatoxinas / Espectrometria de Massas em Tandem / Micotoxinas Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2022 Tipo de documento: Artigo