Your browser doesn't support javascript.
loading
Efficacy of modified folding intraocular lens suspension surgery in treatment of traumatic dislocation of lens / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science ; (12): 1069-1073, 2022.
Artigo em Inglês | WPRIM | ID: wpr-929481
ABSTRACT
@#

AIM:

To evaluate the efficacy of modified folding intraocular lens(IOL)suspension surgery in treatment of traumatic dislocation of lens surgery technique.

METHODS:

Prospective randomized controlled study. A total of 15 patients underwent the modified folding IOL suspension surgery. Among them, 9 patients chose Akreos AO IOL, and polypropylene sutures were used to thread the haptics of IOL. After guided to puncture out through the sclera, the ends of sutures were thermal expanded and fixed in the sclera. And 6 patients chose Tecnis ZA9003 IOL and no sutures were used. After guided the haptics to puncture out through the sclera, the ends of haptics were thermal expanded and fixed in the sclera. The best corrected visual acuity(BCVA, LogMAR)of all patients and postoperative complication were observed.

RESULTS:

This study included 15 patients, among them, 7 were male and 8 were female, the mean age was 64.00±9.85 years old, the mean course of diseases was 5.80±3.17 wk. There were no significant differences between the demographic and baseline clinical characteristics. After underwent the modified folding IOL suspension surgery, visual acuity of all patients were obviously improved. After 3mo of the surgery, the BCVA(LogMAR)of patients were improved from 1.28±0.56 to 0.52±0.30. More specifically, the BCVA(LogMAR)of patients who chose Akreos AO IOL were improved from 1.39±0.62 to 0.59±0.25, and those who chose Tecnis ZA9003 IOL of the BCVA(LogMAR)were improved from 1.12±0.45 to 0.42±0.35. Furthermore, there was no severe postoperative complication observed in our study. Only one patient suffered IOL dislocation and the IOL optical surface was mild oblique.

CONCLUSION:

Modified folding IOL suspension surgery technique resulted in good visual and outcomes with no severe complication, making it an effective option for IOL suspension surgery.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Inglês Revista: International Eye Science Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Inglês Revista: International Eye Science Ano de publicação: 2022 Tipo de documento: Artigo