Study of low-dose CT scan volume rendering technology in evaluating the physeal bar in children / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 492-499, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932858
ABSTRACT

Objective:

To evaluate the feasibility of CT volume rendering technology in the assessment of the physeal bar in children.

Methods:

A retrospective analysis of the relevant CT data of 20 patients with physeal bar from January 2019 to December 2021, 13 boys and 7 girls, age 9.94±2.91 years. The etiology included 17 cases of trauma, 1 cases of tumor, and 2 cases of unknown. The affected sites included 9 cases of distal femur, 5 cases of proximal tibia, 3 cases of distal tibia, and 3 cases of distal radius. Evaluate using volume rendering technology and traditional surface reconstruction technology respectively and the index include the size and type of physeal bar.

Results:

All the children were successfully examined at one time, and none of them required sedation. The average exposure time was 3.81±0.83 s. During scanning, only low-dose radiation was performed on the affected joints, and routine radiation protection was performed. Using volume rendering technology to evaluate the proportion of the physeal bar, the results obtained by the three testers were 25.36%±15.36%, 24.75%±16.18%, 26.70%±17.72%, and the intraclass correlation coefficient value ( ICC) was 0.976, the three repeated measurements by one tester were 25.36%±15.36%, 25.41%±15.20%, 25.74%±16.00% ( ICC=0.990). Compared with the traditional curved planar reconstruction technical evaluation, the results obtained by the three testers were 28.36%±16.74%, 23.66%±19.87%, 35.25%±15.92% ( ICC=0.737), the three repeated measurement results by one tester were 28.36%±16.74%, 31.66%±13.06%, 30.89%±12.52% ( ICC=0.875). The volume rendering technology was better than the curved planar reconstruction technique. Paired t test was performed on the measurement results of three evaluators and the three repeated measurements of the same evaluator, and the differences were statistically significant ( P<0.05). The same results were acquired by using volume rendering technology to evaluate the type of phseal bar with three testers; but there were 18 cases had the same results by using curved planar reconstruction technology and 2 cases had differences, showing the volume rendering technology was more accurate.

Conclusion:

Low-dose CT scanning volume rendering technology is an effective method to evaluate the physeal bar in children. It can more intuitively and accurately evaluate the proportion and type of the bar while reducing the radiation exposure of children. The consistency with inter-group and intra-group is better than traditional curved planar reconstruction technique with good reproducibility and clinical significance.