Your browser doesn't support javascript.
loading
Serial MR Imaging of Magnetically Labeled Humen Umbilical Vein Endothelial Cells in Acute Renal Failure Rat Model
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 181-191, 2013.
Artigo em Inglês | WPRIM | ID: wpr-93363
ABSTRACT

PURPOSE:

To evaluate the usefulness of in vivo magnetic resonance (MR) imaging for tracking intravenously injected superparamagnetic iron oxide (SPIO)-labeled human umbilical vein endothelial cells (HUVECs) in an acute renal failure (ARF) rat model. MATERIALS AND

METHODS:

HUVECs were labeled with SPIO and poly-L-lysine (PLL) complex. Relaxation rates at 1.5-T MR, cell viability, and labeling stability were assessed. HUVECs were injected into the tail vein of ARF rats (labeled cells in 10 rats, unlabeled cells in 2 rats). Follow-up serial T2*-weighted gradient-echo MR imaging was performed at 1, 3, 5 and 7 days after injection, and the MR findings were compared with histologic findings.

RESULTS:

There was an average of 98.4+/-2.4% Prussian blue stain-positive cells after labeling with SPIO-PLL complex. Relaxation rates (R2*) of all cultured HUVECs at day 3 and 5 were not markedly decreased compared with that at day 1. The stability of SPIO in HUVECs was maintained during the proliferation of HUVECs in culture media. In the presence of left unilateral renal artery ischemia, T2*-weighted MR imaging performed 1 day after the intravenous injection of labeled HUVECs revealed a significant signal intensity (SI) loss exclusively in the left renal outer medulla regions, but not in the right kidney. The MR imaging findings at days 3, 5 and 7 after intravenous injection of HUVECs showed a SI loss in the outer medulla regions of the ischemically injured kidney, but the SI progressively recovered with time and the right kidney did not have a significant change in SI in the same period. Upon histologic analysis, the SI loss on MR images was correspondent to the presence of Prussian blue stained cells, primarily in the renal outer medulla.

CONCLUSION:

MR imaging appears to be useful for in vivo monitoring of intravenously injected SPIO-labeled HUVECs in an ischemically injured rat kidney.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Relaxamento / Artéria Renal / Atletismo / Veias Umbilicais / Veias / Compostos Férricos / Espectroscopia de Ressonância Magnética / Sobrevivência Celular / Seguimentos / Meios de Cultura Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Journal of the Korean Society of Magnetic Resonance in Medicine Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Relaxamento / Artéria Renal / Atletismo / Veias Umbilicais / Veias / Compostos Férricos / Espectroscopia de Ressonância Magnética / Sobrevivência Celular / Seguimentos / Meios de Cultura Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Journal of the Korean Society of Magnetic Resonance in Medicine Ano de publicação: 2013 Tipo de documento: Artigo