ABSTRACT
The development of postdural puncture headache is releated to patient's age, size, pregnancy, sex and type of the dural puncture needle, direction of the needle bevel. We studied the effect of needle type, 25 gauge Whitacre and 25 gauge Quincke, on the incidence of postdural puncture headache and other complications after spinal anesthesia in 300 patients. The following results were observed: 1) The incidence of postdural puncture headache is similar between 25 gauge Whitacre needle group and 25 gauge Quincke needle group(4%, respectively). 2) The onset time of headache was 10-48 hours(83%) and the duration was about 48 hours(75%) postoperatively.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Punções / Incidência / Cefaleia Pós-Punção Dural / Cefaleia / Raquianestesia / Agulhas Tipo de estudo: Incidence_studies / Prognostic_studies Limite: Humans / Pregnancy Idioma: Ko Revista: Korean Journal of Anesthesiology Ano de publicação: 1993 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Punções / Incidência / Cefaleia Pós-Punção Dural / Cefaleia / Raquianestesia / Agulhas Tipo de estudo: Incidence_studies / Prognostic_studies Limite: Humans / Pregnancy Idioma: Ko Revista: Korean Journal of Anesthesiology Ano de publicação: 1993 Tipo de documento: Article