Your browser doesn't support javascript.
loading
Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report
Journal of Korean Dental Science ; : 92-99, 2022.
Artigo em Inglês | WPRIM | ID: wpr-938009
ABSTRACT
This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cementtype full zirconia bridge were delivered. At 36 weeks’ follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: Journal of Korean Dental Science Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: Journal of Korean Dental Science Ano de publicação: 2022 Tipo de documento: Artigo