Your browser doesn't support javascript.
loading
Results of Primary Total Knee Arthroplasty in Osteoarthritis with Varus Thrust Knee and Severe Varus Deformity / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 307-314, 2022.
Artigo em Inglês | WPRIM | ID: wpr-938321
ABSTRACT
Purpose@#Varus thrust is an posterolateral rotatory knee motion observed with severe varus patients. It shows a dynamic worsening of varus in the loading response (LR), while returning to a more neutral alignment during the initial contact (IC) of gait. This study examined the results of primary total knee arthroplasty in varus thrust osteoarthritis, including varus thrust motion, gait analysis. @*Materials and Methods@#From March 2009 to March 2019, among 2,391 total knee arthroplasty who underwent total knee arthroplasty, 84 knees from 68 patients with varus thrust and more than a 20° varus deformity were enrolled in this study. The pre-operative and postoperative varus thrust amount (VTA), proximal tibiofibular overlap (PTFOL), and implant position (α, β, γ, and δ) were examined. The gait pattern was analyzed before and after surgery using the footscan ® (RSscan International, Olen, Belgium), evaluating the foot axis-center of pressure angle (FCA) of the ipsilateral foot at the IC and at the LR. The clinical outcomes were evaluated with Hospital for special surgery (HSS). @*Results@#The changes in the VTA were from a pre-operative mean of 5.1° (3.1–7.2) to a mean of 1.9° (0.3–2.8) at the last follow-up (p=0.017). PTFOL changed from pre-operative mean of 18.1 mm (9.0–29.1) to post-operative mean of 11.0 mm (4.2–20.7) (p=0.029). The mean α, β, γ, and δ angle in the last follow-up was 94.6°, 90.3°, 3.86°, and 89.7°, respectively. The FCA in IC was corrected from a pre-operative mean of -1.8° (-1.0 to -4.4) to a post-operative mean of 2.3° (-1.1 to 4.1) (p=0.013). FCA in LR was similar from a pre-operative mean of 5.2° (1.0–7.2) to a post-operative mean of 6.0° (1.1–7.4) (p=0.823). The HSS was changed from a pre-operative mean of 45.7 to a post-operative mean of 86.2 in the last follow-up (p=0.011). @*Conclusion@#Standard total knee arthroplasty in the varus thrust knee showed satisfactory correction of the varus thrust amount and gait pattern, without recurrence of the varus thrust gait. Better clinical results were achieved in total knee arthroplasty of osteoarthritis with a varus thrust without using a constraining implant.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2022 Tipo de documento: Artigo