Your browser doesn't support javascript.
loading
Graft Perforation by a Spinal Bony Spur: An Unusual Cause of Late Bleeding after Thoracoabdominal Aorta Replacement
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 186-188, 2019.
Artigo em Inglês | WPRIM | ID: wpr-939212
ABSTRACT
We report an unusual case of delayed bleeding after open surgical repair of a thoracoabdominal aortic aneurysm. A 79-year-old man developed a massive retroperitoneal hematoma 49 days after Crawford type III thoracoabdominal aorta replacement. During emergency surgery, a tear was found in the prosthetic vascular graft caused by a sharp bony spur arising from the second lumbar vertebral body. This rare, but potentially lethal, complication indicates that attention should be paid to sharp bony structures during open repair of the descending aorta.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2019 Tipo de documento: Artigo