Feasibility of evaluating the left ventricular function in patients with cardiovascular diseases by fully automatic quantified three-dimensional transthoracic echocardiography / 中华心血管病杂志
Chinese Journal of Cardiology
;
(12): 753-758, 2020.
Artigo
em Chinês
| WPRIM
| ID: wpr-941171
ABSTRACT
Objective:
To investigate the clinical value of left ventricular function assessment in patients with cardiovascular disease by fully automatic quantified three-dimensional transthoracic echocardiography.Methods:
One hundred and ninety-seven patients with cardiac diseases were examined by three-dimensional transthoracic echocardiography from September 2017 to May 2019. Data from 61 patients with grade 1 echocardiographic image quality were used to determine the default boundary values of endocardial end-diastolic and end-systolic phases. Clinical features were analyzed based on electronic medical records. The accuracy and repeatability of this strategy was evaluated by comparing left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) measured by automated quantitative three-dimensional echocardiography and those measured by conventional manual transthoracic echocardiography, the latter served as gold standard.Results:
The levels of LVEDV, LVESV and LVEF measured by automatic three-dimensional echocardiography were positively correlated with values obtained by manual measurement(r=0.97,0.97, 0.98, 0.97, 0.97, 0.96;P<0.05). The levels of LVEDV and LVESV measured by full-automatic three-dimensional echocardiography were significantly higher than those obtained by manual three-dimensional echocardiography(all P<0.05). The classification and correlation of systolic dysfunction in patients with abnormal ventricular wall motion by automatic three-dimensional echocardiography were significantly improved after manual calibration (κ=0.74, P=0.00) as compared to without manual calibration (κ=0.63, P=0.00). The inter-observer and intra-observer variability of fully automated three-dimensional echocardiography were significantly smaller than manual three-dimensional echocardiography(both P<0.05).Conclusion:
Fully automatic quantified three-dimensional transthoracic echocardiography possesses excellent accuracy and repeatability in measuring left ventricular volume and function, and it is feasible for clinical application.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Volume Sistólico
/
Ecocardiografia
/
Doenças Cardiovasculares
/
Estudos de Viabilidade
/
Função Ventricular Esquerda
/
Ecocardiografia Tridimensional
Tipo de estudo:
Guia de Prática Clínica
Limite:
Humanos
Idioma:
Chinês
Revista:
Chinese Journal of Cardiology
Ano de publicação:
2020
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS