ABSTRACT

Objective:

To investigate the clinical characteristics of inpatients with the indication of cardiac implantable electronic devices (CIED) therapy and combined acute pulmonary thromboembolism (APTE).

Methods:

We retrospectively screened 8 641 inpatients who admitted with the indication of CIED implantation in Fuwai Hospital from January 2014 to May 2019. The clinical characteristics, management strategies and clinical outcome were analyzed for patients diagnosed as APTE.

Results:

APTE were identified in 45 (5‰) patients in this cohort, there were 18(40%) male patients, the average age was (73±8) years old and body mass index was (27±10) kg/m2.Thirty-two (70%) patients were at intermediate-risk and 13 (30%) at low-risk. Anti-coagulation therapy was initiated in 38(84%) patients, and 30 patients underwent CIED implantation (27 pacemaker, 2 CRT and 1 ICD). No postoperative bleeding or pocket hematoma were detected in the 23 patients taking anticoagulation medication before implantation. During an average of (30±7) months' follow up, thrombus was dissolved in 20 patients, hemorrhage complications were observed in 2 patients (1 cerebral hemorrhage and 1 hematuria), anticoagulation therapy was discontinued in these 2 patients. Among 15 patients without immediate CIED implantation and treated with anticoagulation therapy during hospitalization, 2 patients developed complete paroxysmal Ⅲ° atrioventricular block, and recovered after therapy during hospitalization. Seven patients were re-hospitalized for CIED implantation due to bradycardia. Five patients died during follow-up (3 sudden cardiac death, 1 APTE combined with cerebral infarction, and 1 pulmonary infection).

Conclusion:

APTE is not rare in patients with the indication of CIED implantation, CIED implantation and anti-coagulation therapy are safe for these patients, and transient atrioventricular block could be detected in APTE patients.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Marca-Passo Artificial / Embolia Pulmonar / Estudos Retrospectivos / Morte Súbita Cardíaca / Desfibriladores Implantáveis Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Marca-Passo Artificial / Embolia Pulmonar / Estudos Retrospectivos / Morte Súbita Cardíaca / Desfibriladores Implantáveis Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2020 Tipo de documento: Artigo