ABSTRACT

Objective:

To investigate the safety and efficacy of left ventricular guidewire pacing during transcatheter aortic valve replacement (TAVR).

Methods:

This is a retrospective study. Thirteen patients, who underwent TAVR with left ventricular guidewire pacing from October 2019 to December 2019 in Fuwai Hospital, were included. Clinical data and operational procedure data of the patients were collected. Changes in blood pressure and electrocardiogram were observed during operations. Ascending aorta angiography was performed to evaluate the regurgitation of aortic valve after valve implantion. The incidence of major adverse cardiac events during hospitalization and at 3-months after discharge was recorded.

Results:

There were 7 male and 6 female patients in this cohort,and age was (73.8±8.3) years old. Among the 13 patients, 9 were tricuspid aortic valves, 3 were bicuspid aortic valves, and 1 was degenerated bioprosthetic surgical aortic valve. TAVR were successfully performed in all of the 13 cases using pacing through the left ventricular guidewire. During balloon dilation, the blood pressure decreased to below 60 mmHg (1 mmHg=0.133 kPa) after 180 beats/min pacing, and the valve release process was smooth and the position was stable. The results of aortography showed that there was no regurgitation in 7 cases, mild regurgitation in 5 cases and moderate regurgitation in 1 case. Three patients required temporary pacing during the procedure due to complete heart block, among whom 1 patient was implanted with permanent pacemaker during hospitalization, and the other 2 patients recovered within 24 hours after operation. In another case, there was no significant change of electrocardiogram during the operation, and complete heart block occurred 10 days after the operation, and treated with permanent pacemaker. The other 10 patients began to carry out bedside activities and rehabilitation training 24 hours after operation. There was no death, myocardial infarction, stroke and other major adverse cardiac events during hospitalization and at 3-month follow-up after discharge.

Conclusion:

Left ventricular guidewire pacing is a safe and effective strategy for TAVR.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Estudos Retrospectivos / Fatores de Risco / Resultado do Tratamento / Substituição da Valva Aórtica Transcateter Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2021 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Estudos Retrospectivos / Fatores de Risco / Resultado do Tratamento / Substituição da Valva Aórtica Transcateter Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2021 Tipo de documento: Artigo