Your browser doesn't support javascript.
loading
Clinical application value of transthoracic echocardiography during perioperative period in patients undergoing left ventricular assist device implantation / 中华心血管病杂志
Chinese Journal of Cardiology ; (12): 610-614, 2021.
Artigo em Chinês | WPRIM | ID: wpr-941325
ABSTRACT

Objective:

To observe the changes of parameters derived from transthoracic echocardiography (TTE) before and after left ventricular assist device (LVAD) implantation, and to evaluate the clinical value of TTE in the perioperative period of LVAD implantation.

Methods:

This is a retrospective study. The data of patients who underwent LVAD implantation in Fuwai Hospital from January 2018 to December 2020 were analyzed retrospectively. The TTE parameters, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and total bilirubin (TBil) before and 1 month after LVAD implantation were collected and analyzed.

Results:

A total of 12 male patients undergoing LVAD implantation were included in this study. The mean age was (43.3±8.6) years. The left atrial volume index ((41.4±12.8)ml/m2 vs. (74.9±30.7)ml/m2, P<0.001), left ventricular end-diastolic volume index ((152.1±35.3)ml/m2 vs. (205.5±35.7)ml/m2, P<0.001), left ventricular end-systolic volume index ((112.5±27.9)ml/m2 vs. (155.1±29.1)ml/m2, P<0.001), right atrial diameter index ((23.7±3.5)mm/m2 vs. (27.2±5.8)mm/m2, P=0.023), right ventricular internal diameter at end-diastole ((24.6±2.7)mm vs. (30.0±4.8)mm, P<0.001), tricuspid annular plane systolic excursion ((11.5±2.9)mm vs. (14.6±2.8)mm, P=0.007), systolic pulmonary arterial pressure ((29.2±4.8) mmHg vs. (55.1±19.3) mmHg, P<0.001, 1 mmHg=0.133 kPa) were significantly reduced at 1 month post LVAD implantation as compared to before LVAD implantation. The aortic sinus diameter ((33.8±4.7)mm vs. (31.6±5.1)mm, P=0.007), left ventricular ejection fraction ((26.3±3.0)% vs. (23.8±4.4)%, P=0.016), right ventricular fractional area change ((31.0±8.6)% vs. (23.8±5.5)%, P=0.004) at 1 month post LVAD implantation were significantly higher than before LVAD implantation. The degree of mitral and tricuspid regurgitation decreased, and the inspiratory collapse rate of inferior vena cava increased (all P<0.05). NT-proBNP ((1 418.4±812.6)ng/L vs. (5 097.5±3 940.4)ng/L, P=0.004) and TBil ((12.4±5.4)μmol/L vs. (27.5±14.0)μmol/L, P=0.001) decreased significantly at 1 month post LVAD implantation.

Conclusions:

TTE results show that LVAD could effectively relieve left ventricular load and improve right ventricular function. TTE can monitor the cardiac structural and functional changes during the perioperative period of LVAD implantation, and provide the imaging evidence for clinical evaluation of the therapeutic effect of LVAD.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Volume Sistólico / Ecocardiografia / Coração Auxiliar / Estudos Retrospectivos / Função Ventricular Esquerda / Período Perioperatório / Insuficiência Cardíaca Tipo de estudo: Estudo observacional Limite: Adulto / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2021 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Volume Sistólico / Ecocardiografia / Coração Auxiliar / Estudos Retrospectivos / Função Ventricular Esquerda / Período Perioperatório / Insuficiência Cardíaca Tipo de estudo: Estudo observacional Limite: Adulto / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2021 Tipo de documento: Artigo