Your browser doesn't support javascript.
loading
Application of Rotarex mechanical thrombectomy system in treating in-stent restenosis of lower extremity arteriosclerosis obliterans / 北京大学学报(医学版)
Journal of Peking University(Health Sciences) ; (6): 740-743, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942246
ABSTRACT
OBJECTIVE@#To evaluate the role of Rotarex mechanical thrombectomy system in treating instent restenosis of peripheral artery disease (PAD).@*METHODS@#The clinical data of 7 in-stent restenosis (ISR) cases of lower extremity PAD from June 2017 to Dec 2018 were retrospectively analyzed. There were 5 males and 2 females and the mean age was (70.0±7.6) years from 59.0 to 76.0 years. All the cases were treated by Rotarex mechanical thrombectomy system. In the 7 cases, time interval from the previous stent implantation to ischemia recurrence was 1.0 to 72.0 months, and the median time was 6.0 months. The period from ischemia recurrence to endovascular therapy was 3 days to 2 years, and the median time was 62 days. Rotarex mechanical debulking catheter and percutaneous transluminal angioplasty (PTA) were used in all the cases, and the stent was used only when it was necessary. Anticoagulation was used for 24 hours after procedures and then antiplatelet agents were used as usual. Doppler ultrasonography was taken during the followed-up.@*RESULTS@#All the 7 cases were successful in technology, 3 of which were implanted with new stents for the fracture of the old ones. while for the other four cases, no new stent was implanted. The ankle-brachial index (ABI) increased from 0.31±0.08 to 0.86±0.08 after treatment (t=-12.84, P < 0.001). Thrombectomy was applied urgently in one case because of acute thrombosis in the stent, and the result was good. There was no other complications in hospital. All the patients were followed up for 5.0-22.0 months, and the median time was 14.0 months. No death and amputation occurred during the follow-up. One patient stopped antiplatelet agents because of gastrointestinal bleeding, which resulted in acute thrombosis. in-stent restenosis reappeared in 3 cases.@*CONCLUSION@#Debulking using Rotarex catheter is safe and effective in treating in-stent restenosis of PAD, especially in reducing stents implantation, but is not good at dealing with old thrombus and proliferating intima, and can do nothing about fractured stents and hyperplasia of intima, so it needs to be combined with stents and drug coated balloons.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Arteriosclerose Obliterante / Recidiva / Stents / Estudos Retrospectivos / Resultado do Tratamento / Trombectomia / Reestenose Coronária / Extremidade Inferior / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Journal of Peking University(Health Sciences) Ano de publicação: 2021 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Arteriosclerose Obliterante / Recidiva / Stents / Estudos Retrospectivos / Resultado do Tratamento / Trombectomia / Reestenose Coronária / Extremidade Inferior / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Journal of Peking University(Health Sciences) Ano de publicação: 2021 Tipo de documento: Artigo