Your browser doesn't support javascript.
loading
Safety Study of Implant Wearers in MRI RF Field Environment / 中国医疗器械杂志
Chinese Journal of Medical Instrumentation ; (6): 101-107, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942708
ABSTRACT
The complex electromagnetic field environments in magnetic resonance imaging system(MRI) can have a significant impact on patients carrying implants, the RF heating problems being particularly important. To ensure the safety of the patients, it is necessary to understand the distribution of tissue temperature in the MRI environment and its changes over time. Based on the analysis of tissue temperature rise in MRI, this paper constructs a bird cage coil for generating RF field in MRI system, and constructs ASTM standard/improved phantom and single-cavity pacemaker finite element models, use time-domain finite difference (FDTD) to simulate. Firstly, the correctness of the simulation software and simulation method was validated according to the method of ISO. Then the distribution of the electric field, SAR and temperature field and the temperature change with time were calculated in the environment of 64 MHz, 2 W/kg. The difference in temperature rise with blood heat exchange and no blood heat exchange (standard/improved phantom) was specifically compared. The simulation results show that there are electric field and SAR hotspots near the electrode tip, the wire tail and the case of pacemaker. There are high SAR values on both sides of the phantom, and the shorter the distance from the coil, the higher the SAR. The temperature field distribution is similar to the SAR distribution; the temperature is higher in the area around the end of the wire and the case of pacemaker because the heat accumulation is higher around this area. At the same time, blood heat exchange can reduce the temperature rise to a certain extent.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Temperatura / Imageamento por Ressonância Magnética / Imagens de Fantasmas / Campos Eletromagnéticos / Modelos Teóricos Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Medical Instrumentation Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Temperatura / Imageamento por Ressonância Magnética / Imagens de Fantasmas / Campos Eletromagnéticos / Modelos Teóricos Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Medical Instrumentation Ano de publicação: 2020 Tipo de documento: Artigo