Your browser doesn't support javascript.
loading
Application of prospective respiratory gating based on 4D-CT in precise radiotherapy for lung cancer / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology ; (6): 605-610, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956883
ABSTRACT

Objective:

The respiratory waveform of lung cancer patients based on 4D-CT respiratory gating was analyzed to evaluate the accuracy of gating during radiotherapy, and to explore the off-target in the 4D-CT respiratory gating radiotherapy.

Methods:

Clinical data of 18 patients with lung cancer admitted to Radiotherapy Department of Jiangsu Cancer Hospital were collected to obtain the respiratory waveform data during 4D-CT respiratory gating radiotherapy. The waveform in each treatment working cycle was compared with the waveform in 4D-CT scan to study whether there was a possibility of the off-target in the treatment of lung cancer patients.

Results:

There were 154 treatment sessions and 20,790 treatment breathing cycles in 18 patients, among which the threshold of gated opening beam miss amplitude (Δm-en) was greater than 0 in 95 treatment breathing cycles in 7 patients, accounting for 0.46% of all breathing cycles, and the threshold of gated closing beam miss amplitude (Δm-dis) was greater than 0 in 1419 treatment breathing cycles in 13 patients, accounting for 6.83% of all cycles. Among the 13 patients withΔm-dis greater than 0, actual tumor range of motion (R G) was greater than the sum of the value of target margin (M) and the value of plan tumor range of motion (R T) in 7 patients, R G was more than 1.5 times of M+R T in 7 patients, and there were also 7 patients in the phase of rapid rise and fall of respiratory curve. The correlation efficients between R G-M-R T and the percentage of beam on miss phase (T en%) and the percentage of beam closing off phase (T dis%) were 0.41 and 0.57, respectively.

Conclusion:

When R G is more than 1.5 times of M+R T value and the gating beam on phase contains the phases in the rapid rise and fall of the respiratory curve, the possibility of the off-target during radiotherapy is significantly increased.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiation Oncology Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiation Oncology Ano de publicação: 2022 Tipo de documento: Artigo