Your browser doesn't support javascript.
loading
Development and preliminary evaluation of a fluorescence RPA assay for the rapid detection of Necator americanus / 中国热带医学
China Tropical Medicine ; (12): 681-2023.
Artigo em Chinês | WPRIM | ID: wpr-979787
ABSTRACT
@#Abstract Objective To establish a rapid detection assay based on fluorescence recombinase polymerase amplification (RPA) targeting Necator americanus eggs, and to evaluate its efficacy, providing technical support for rapid detection of Necator americanus in fecal samples. Methods The fluorescence RPA primers and probe were designed based on the cox1 gene of Necator americanus and then screened the optimal combination to develop the assay. The genomic DNA of Necator americanus eggs was diluted to 7 concentration gradients including 100 pg/µL, 10 pg/µL, 1 pg/µL, 100 fg/µL, 10 fg/µL, 1 fg/µL, 0.1 fg/µL, to determine the detection limit of the assay. The specificity of the assay was demonstrated by detected genomic DNA from Schistosoma japonicum, Ascaris lumbricoides, Clonorchis sinensis and Fasciola hepatica. A total of 44 fecal samples were collected and DNA extraction was performed, and the modified Kato-Katz method, semi-nest PCR method, and fluorescent RPA method were simultaneously used for detection to evaluate the sensitivity and specificity. Results The established fluorescence RPA assay can specifically amplify a fragment of 194 bp of the Necator americanus cox1 gene within 20 min, with a detection limit of 10 fg/µL. There was no cross-reactivity with Schistosoma japonicum, Ascaris lumbricoides, Clonorchis sinensis, Fasciola hepatica after specificity validation. In 44 fecal samples, 27 positive samples were detected by the fluorescence RPA assay, and 26 positive samples were detected by both the Kato-Katz and the semi-nested PCR. The fluorescence curve of sample number 1 was slightly higher than the negative control in the later stage of the reaction, but did not show a similar trend to the positive control, and was therefore judged to be a suspected negative sample. Compared with the Kato-Katz method and the semi-nest PCR method, The sensitivity of the fluorescent RPA method were 100.00% and the specificity were 94.44%, and the consistency of the detection results was good (Kappa=0.953>0.75). Conclusions The assay based on the fluorescence RPA is an efficient, sensitive and specific technique for detecting Necator americanus and it can be applied for surveillance and early warning of hookworm infection.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Tropical Medicine Ano de publicação: 2023 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Tropical Medicine Ano de publicação: 2023 Tipo de documento: Artigo