Your browser doesn't support javascript.
loading
Effects of electroacupuncture on cardiac function and local field potential of sensory and motor cortices in mice with stress cardiomyopathy / 中国针灸
Chinese Acupuncture & Moxibustion ; (12): 379-389, 2023.
Artigo em Chinês | WPRIM | ID: wpr-980732
ABSTRACT
OBJECTIVE@#To observe the effects of electroacupuncture (EA) on cardiac function and local field potential (LFP) in sensory and motor cortices in mice with stress cardiomyopathy (SC), and to explore the possible mechanism of EA in improving SC.@*METHODS@#Twenty-seven female C57BL/6 mice were randomized into a blank group, a model group and an EA group, 9 mice in each group. In the model group and the EA group, SC model was established by continuous intraperitoneal injection of isoproterenol (ISO) for 14 days. At the same time of modeling, EA was applied at "Neiguan" (PC 6) and "Shenmen" (HT 7) in the EA group, with disperse-dense wave, in frequency of 2 Hz/15 Hz, 15 min each time, once a day for 14 days. After intervention, the total movement distance, the number of crossing grid and the number of crossing central grid of open field test within 5 minutes were observed; the left ventricular function indexes (left ventricular diameter of end-diastole [LVIDd], left ventricular diameter of end-systole [LVIDs], left ventricular volume of end-diastole [LVEDV], left ventricular volume of end-systole [LVESV], ejection fraction [EF] and fraction shortening [FS]) were detected by echocardiography; the changes in ST-segment amplitude and PR interval of electrocardiogram were observed; the morphology of myocardial tissue was observed by HE staining; the serum levels of cortisol (CORT), cardiac troponin T (cTnT) and brain natriuretic peptide (BNP) were detected by ELISA; the changes of LFP in sensory and motor cortices were recorded by Plexon multi-channel acquisition system.@*RESULTS@#Compared with the blank group, in the model group, the total movement distance, the number of crossing grid and the number of crossing central grid of open field test were decreased (P<0.05); LVIDd, LVIDs, LVEDV and LVESV were increased (P<0.05), EF and FS were decreased (P<0.05); ST-segment amplitude was increased (P<0.05) and PR interval was prolonged (P<0.05); irregular myocardial fiber arrangement, interstitial edema and inflammatory cell infiltration were observed; the serum levels of CORT, cTnT and BNP were increased (P<0.05); in the sensory cortex, the ratios of delta, theta, alpha and beta frequency bands were increased (P<0.05), the maximum energy spectrum of theta and beta frequency bands was increased (P<0.05), the power spectral density (PSD) of delta, theta, alpha, beta and gamma frequency bands was increased (P<0.05); in the motor cortex, the ratios of delta, theta, alpha and beta frequency bands were increased (P<0.05), the maximum energy spectrum as well as PSD of delta, theta, alpha, beta and gamma frequency bands were increased (P<0.05). Compared with model group, in the EA group, the total movement distance, the number of crossing grid and the number of crossing central grid of open field test were increased (P<0.05); LVIDd, LVIDs, LVEDV and LVESV were decreased (P<0.05), EF and FS were increased (P<0.05); ST-segment amplitude was decreased (P<0.05), and the PR interval was shortened (P<0.05); myocardial fiber injury and inflammatory cell infiltration were reduced; the serum levels of CORT, cTnT and BNP were decreased (P<0.05); in the sensory cortex, the ratios of theta, alpha and beta frequency bands were decreased (P<0.05), the ratio of gamma frequency band was increased (P<0.05), the maximum energy spectrum of theta frequency band as well as the PSD of theta, alpha, beta and gamma frequency bands were decreased (P<0.05); in the motor cortex, the ratios of theta, alpha and beta frequency bands were decreased (P<0.05) and the ratio of gamma frequency band was increased (P<0.05), the maximum energy spectrum of delta frequency band was increased (P<0.05), the maximum energy spectrum of theta frequency band as well as the PSD of theta and gamma frequency bands were decreased (P<0.05).@*CONCLUSION@#EA can improve cardiac function in mice with stress cardiomyopathy, and its mechanism may be related to the regulation of local field potentials in sensory and motor cortices.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Eletroacupuntura / Cardiomiopatia de Takotsubo / Camundongos Endogâmicos C57BL / Córtex Motor / Miocárdio Limite: Animais Idioma: Chinês Revista: Chinese Acupuncture & Moxibustion Ano de publicação: 2023 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Eletroacupuntura / Cardiomiopatia de Takotsubo / Camundongos Endogâmicos C57BL / Córtex Motor / Miocárdio Limite: Animais Idioma: Chinês Revista: Chinese Acupuncture & Moxibustion Ano de publicação: 2023 Tipo de documento: Artigo