Effect of PCR reaction volume on the accuracy of human identification tests / 法医学杂志
Journal of Forensic Medicine
;
(6): 155-159, 2002.
Artigo
em Chinês
| WPRIM
| ID: wpr-982952
ABSTRACT
OBJECTIVE@#To investigate the effect of different PCR amplification volume on the accuracy of human identification test.@*METHODS@#Human genome DNA samples were amplified using ABI PRISM Profiler Plus kits in 50 microliters, 25 microliters, 12.5 microliters, and 6.25 microliters reaction volume, respectively. The thermocycle parameters were the same. All PCR products were then electrophoresized on ABI PRISM 310 Genetic Analyzer, 377 DNA Sequencer, and 3100 Genetic Analyzer. Data were processed by ABI PRISM GeneScan and Genotyper software.@*RESULTS@#The less reaction volume, the more alleles losing or alleles adding observed.@*CONCLUSION@#Non-standard volume of PCR amplification reaction should be used carefully in human identification test, especially when the sample DNA quality is not so satisfied.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Espectrofotometria Ultravioleta
/
Manchas de Sangue
/
DNA
/
Reação em Cadeia da Polimerase
/
Sensibilidade e Especificidade
/
Perda de Heterozigosidade
/
Eletroforese
/
Alelos
/
Medicina Legal
Limite:
Humanos
Idioma:
Chinês
Revista:
Journal of Forensic Medicine
Ano de publicação:
2002
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS