Your browser doesn't support javascript.
loading
Effects of Postmortem Hemolysis and Ultrafiltration on Creatinine Detection Results / 法医学杂志
Journal of Forensic Medicine ; (6): 697-701, 2022.
Artigo em Inglês | WPRIM | ID: wpr-984160
ABSTRACT
OBJECTIVES@#To investigate the interference of postmortem hemolysis on the detection of creatinine and whether ultrafiltration can reduce the interference.@*METHODS@#A total of 33 non-hemolyzed whole blood samples from the left heart were collected. Hemolyzed samples with 4 hemoglobin mass concentration gradients H1-H4 were artificially prepared. Ultrafiltration was performed on each hemolyzed sample. Creatinine concentrations in non-hemolyzed serum (baseline serum), hemolyzed samples and ultrafiltrate were detected. Bias (B), Pearson correlation and receiver operator characteristic (ROC) of baseline creatinine concentration between before and after ultrafiltration were analyzed.@*RESULTS@#As the hemoglobin mass concentration increased, B of the hemolyzed samples in the H1-H4 groups gradually increased, the |B| was 2.41(0.82, 8.25)-51.31(41.79, 188.25), reaching a maximum of 589.06%, and there was no statistically significant between the creatinine concentration and the baseline creatinine concentration (P=0.472 7, r=0.129 5). After ultrafiltration of hemolyzed samples, the interference of creatinine concentration in ultrafiltrate was significantly reduced, the |B| was 5.32(2.26, 9.22)-21.74(20.06, 25.58), reaching a maximum of 32.14%, and there was a positive correlation with baseline creatinine concentration (P<0.05, r=0.918 2). In the hemolyzed samples of H3 and H4 groups, there were 7 false-positive samples and 1 false-negative sample; in the ultrafiltrate samples, there were no false-positive sample and 1 false-negative sample. ROC analysis results showed the hemolyzed samples were lack of diagnostic value (P=0.117 5).@*CONCLUSIONS@#The postmortem hemolysis significantly interferes creatinine detection results of blood samples, ultrafiltration can reduce hemolysis-induced interference in postmortem creatinine detection.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Hemoglobinas / Ultrafiltração / Creatinina / Soro / Hemólise Limite: Humanos Idioma: Inglês Revista: Journal of Forensic Medicine Ano de publicação: 2022 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Hemoglobinas / Ultrafiltração / Creatinina / Soro / Hemólise Limite: Humanos Idioma: Inglês Revista: Journal of Forensic Medicine Ano de publicação: 2022 Tipo de documento: Artigo