ABSTRACT
Objective:
To investigate various clinical treatment measures for thoracolumbar fractures and provide new diagnosis and treatment methods.Methods:
The case data of 5 patients(3 males, 2 females, and the age ranged from 39 to 59 years with an average of 51 years) with thoracolumbar fractures were treated with Waveflex semi-rigid internaI fixation system from May 2020 to December 2021 were retrospectively analyzed, imaging indexes and clinical effects were followed up, and analyzed and summarized in combination with relevant literatures.Results:
The operations of all 5 patients were successfully completed, and the follow-up period was 6 months. At the last follow-up, the internal fixation position was good, the height of the injured vertebra was maintained satisfactorily, and the clinical effect was satisfactory.Conclusion:
Waveflex semi-rigid internal fixation system combines the advantages of fusion and non-fusion, providing a new idea for the treatment of thoracolumbar fractures, but its long-term effect still needs further follow-up.