ABSTRACT

Objective:

To establish standard spatial brain template and ROIs template of 11C-methyl- N-2β-carbomethoxy-3β-(4-fluorophenyl)tropane (CFT) PET images for automated quantitative analysis of dopamine transporter (DAT) distribution.

Methods:

From May 2014 to December 2015, 11C-CFT PET and MRI T 1 brain images of 16 healthy volunteers (3 males, 13 females; age (63.3±6.9) years) from Huashan Hospital, Fudan University were co-registered and smoothed using statistical parametric mapping(SPM)5 software based on MATLAB to create a standard spatial brain template. The ROIs template was established by ScAnVp procedures. These templates were clinically verified by using 11C-CFT PET images of 37 healthy volunteers (23 males, 14 females; age (61.7±7.1) years), 32 Parkinson′s disease (PD) patients (20 males, 12 females; age (61.1±5.4) years), 10 multiple system atrophy with predominant parkinsonism (MSA-P) patients (7 males, 3 females; age (60.8±7.1) years) and 10 progressive supranuclear palsy (PSP) patients (5 males, 5 females; age (58.4±6.1) years) from Huashan Hospital, Fudan University between January 2014 and March 2019. One-way analysis of variance was used to analyze data.

Results:

Based on the 11C-CFT PET images and MRI T 1 images of healthy volunteers, a standard spatial brain template for normalization of 11C-CFT PET images was created. The ROIs template was established including seven regions bilateral caudate, anterior putamen, posterior putamen (along the long axis) and the occipital cortex. The ROIs template was accurately aligned in each verification group. The normal reference values of semi-quantitative DAT distribution in caudate, anterior putamen and posterior putamen were obtained (1.84±0.13, 2.18±0.16, 1.77±0.11). The semi-quantitative values of 11C-CFT uptake in each ROI in patients were significantly lower than those in healthy volunteers ( F values 49.79-283.83, all P<0.05).

Conclusion:

The established brain templates with accurate spatial alignment for 11C-CFT image analysis can provide foundational tools for the application of 11C-CFT PET imaging in clinical practice and scientific research.