Your browser doesn't support javascript.
loading
Analysis of external quality assessment results of quality indicators for national emergency examination turnaround time / 中华检验医学杂志
Chinese Journal of Laboratory Medicine ; (12): 719-724, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995783
ABSTRACT

Objective:

To establish preliminary quality specifications for emergency examination turnaround time (TAT).

Methods:

The National Center for Clinical Laboratories organized 31 provinces (autonomous regions and municipalities directly) and Xinjiang production and Construction Corps centers to launch a synchronous Quality Indicators (QIs)-External Quality Assessment (EQA) program and the collected data were reported via developed online EQA system. The essential information of the clinical laboratories, the data of pre-examination and intra-laboratory TAT quality indicators of emergency departments at each specialty (biochemistry, automatic immunity, three routines tests and coagulation) and four specific tests (blood potassium, troponin I/T, white blood cell count and international normalized ratio (INR)) were collected from 2019 to 2021. TAT returned the median and 90th percentile ( P90) of the specified month were calculated. The median (lower quartile, upper quartile) of the TAT returned laboratories were calculated and second result grading statistics for 2021 (2 422 tertiary hospital and 5 088 secondary hospital) were performed to understand the difference of pre-examination and the laboratory TAT between different tertiary hospitals.

Results:

From 2019 to 2021, there were 9 540 laboratories, 9 709 laboratories and 10 653 returned laboratories. The pre-examination TAT of each specialty was similar, and the results were relatively stable. The median distribution was about 15 (10, 30) min, and the monthly P90 distribution was about 20 (10, 30) min. The distribution results of the median intra-laboratory TAT in each specialty were as follows automatic immunitybiochemistry>coagulation>three routine tests. The distribution of the latest (second result in 2021) survey results of each specialty were as follows automatic immunity 53 (30, 60) min, biochemistry 45 (30, 60) min, coagulation 30 (23, 40) min, and three routine tests 20 (11, 30) min. The median results of monthly P90 of intra-laboratory TAT were as follows 60 min for automatic immunity and biochemistry specialty, about 38 min for coagulation specialty, and about 27 min for three routines tests. The hierarchical statistical results showed that the monthly P90 distribution of laboratory TAT of the pre-examination and intra-laboratory TAT from the tertiary hospital was higher than that of the secondary hospital. The pre-examination TAT of each specialty of the tertiary hospital/secondary hospital was as follows biochemistry 35 (22, 60)/20 (11, 30) min, automatic immunity 33 (20, 60)/20 (10, 30) min, three routine tests 30 (20, 49)/20 (10, 30) min and coagulation 31 (20, 58)/20 (10, 30) min, the intra-laboratory TAT of each specialty of the tertiary hospital/secondary hospital was as follows biochemistry 65 (50, 91)/60 (40, 70) min, automatic immunity 75 (55, 113)/60 (40, 90) min, three routine tests 30 (23, 38)/28 (19, 30) min and coagulation 53 (36, 72)/35 (30, 57) min. In terms of the distribution results of the median of intra-laboratory TAT of the four specific tests, 96.76% (9 484/9 801) of the blood potassium and 95.96% (8 733/9 101) of the troponin I/T medical institutions were TAT within 69 min in the laboratories, 95.34% (9 679/10 152) of the white blood cell count medical institutions were TAT within 31 min in the laboratories, and 98.85% (9 462/9 572) of the INR medical institutions were TAT within 66 min in the laboratories.

Conclusions:

This survey provides a preliminary quality specification for the emergency department turnaround time at each specialty. Lower quartile, median and upper quartile of the monthly P90 at the tertiary and secondary hospitals can be used to define the best, appropriate and minimum performance levels, respectively.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Laboratory Medicine Ano de publicação: 2023 Tipo de documento: Artigo

Similares