ABSTRACT
ABSTRACT Real-time digital PCR (qdPCR) coupled with artificial intelligence has shown the potential of unlocking scientific breakthroughs, particularly in the field of molecular diagnostics for infectious diseases. One of the most promising applications is the use of machine learning (ML) methods to enable single fluorescent channel PCR multiplex by extracting target-specific kinetic and thermodynamic information contained in amplification curves. However, the robustness of such methods can be affected by the presence of undesired amplification events and nonideal reaction conditions. Therefore, here we proposed a novel framework to filter non-specific and low efficient reactions from qdPCR data using outlier detection algorithms purely based on sigmoidal trends of amplification curves. As a proof-of-concept, this framework is implemented to improve the classification performance of the recently reported ML-based Amplification Curve Analysis (ACA), using available data from a previous publication where the ACA method was used to screen carbapenemase-producing organisms in clinical isolates. Furthermore, we developed a novel strategy, named Adaptive Mapping Filter (AMF), to consider the variability of positive counts in digital PCR. Over 152,000 amplification events were analyzed. For the positive reactions, filtered and unfiltered amplification curves were evaluated by comparing against melting peak distribution, proving that abnormalities (filtered out data) are linked to shifted melting distribution or decreased PCR efficiency. The ACA was applied to compare classification accuracies before and after AMF, showing an improved sensitivity of 1.18% for inliers and 20% for outliers (p-value < 0.0001). This work explores the correlation between kinetics of amplification curves and thermodynamics of melting curves and it demonstrates that filtering out non-specific or low efficient reactions can significantly improve the classification accuracy for cutting edge multiplexing methodologies.
Subject(s)
Communicable Diseases , Space Motion SicknessABSTRACT
The COVID-19 pandemic is a global health emergency characterized by the high rate of transmission and ongoing increase of cases globally. Rapid point-of-care (PoC) diagnostics to detect the causative virus, SARS-CoV-2, are urgently needed to identify and isolate patients, contain its spread and guide clinical management. In this work, we report the development of a rapid PoC diagnostic test (< 20 min) based on reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) and semiconductor technology for the detection of SARS-CoV-2 from extracted RNA samples. The developed LAMP assay was tested on a real-time benchtop instrument (RT-qLAMP) showing a lower limit of detection of 10 RNA copies per reaction. It was validated against 183 clinical samples including 127 positive samples (screened by the CDC RT-qPCR assay). Results showed 90.55% sensitivity and 100% specificity when compared to RT-qPCR and average positive detection times of 15.45 {+/-} 4.43 min. For validating the incorporation of the RT-LAMP assay onto our PoC platform (RT-eLAMP), a subset of samples was tested (n=40), showing average detection times of 12.89 {+/-} 2.59 min for positive samples (n=34), demonstrating a comparable performance to a benchtop commercial instrument. Paired with a smartphone for results visualization and geo-localization, this portable diagnostic platform with secure cloud connectivity will enable real-time case identification and epidemiological surveillance.
Subject(s)
COVID-19ABSTRACT
Objectives: To evaluate SARS-CoV-2 surface and air contamination during the peak of the COVID-19 pandemic in London. Design: Prospective cross-sectional observational study. Setting: An acute NHS healthcare provider. Participants: All inpatient wards were fully occupied by patients with COVID-19 at the time of sampling. Interventions: Air and surface samples were collected from a range of clinical areas and a public area of the hospital. An active air sampler was used to collect three or four 1.0 m3 air samples in each area. Surface samples were collected by swabbing approximately 25 cm2 of items in the immediate vicinity of each air sample. SARS-CoV-2 was detected by RT-qPCR and viral culture using Vero E6 and Caco2 cells; additionally the limit of detection for culturing SARS-CoV-2 dried onto surfaces was determined. Main outcome measures: SARS-CoV-2 detected by PCR or culture. Results: Viral RNA was detected on 114/218 (52.3%) of surface and 14/31 (38.7%) air samples but no virus was cultured. The proportion of surface samples contaminated with viral RNA varied by item sampled and by clinical area. Viral RNA was detected on surfaces and in air in public areas of the hospital but was more likely to be found in areas immediately occupied by COVID-19 patients (67/105 (63.8%) in areas immediately occupied by COVID-19 patients vs. 29/64 (45.3%) in other areas (odds ratio 0.5, 95% confidence interval 0.2-0.9, p=0.025, Fishers exact test). The PCR Ct value for all surface and air samples (>30) indicated a viral load that would not be culturable. Conclusions: Our findings of extensive viral RNA contamination of surfaces and air across a range of acute healthcare settings in the absence of cultured virus underlines the potential risk from surface and air contamination in managing COVID-19, and the need for effective use of PPE, social distancing, and hand/surface hygiene.