Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Sci Rep ; 12(1): 13069, 2022 Jul 29.
Article in English | MEDLINE | ID: covidwho-1967624

ABSTRACT

Reverse transcription quantitative PCR (RT-qPCR) assays are gold standard in diagnosing SARS-CoV-2 infection and play a major role in viral subtyping for rapid detection and monitoring of important mutations, containing the spread of new virus variants. We wanted to compare RT-qPCR melting curve analysis assays to Sanger Sequencing for detection of variants within the SARS-CoV-2 spike glycoprotein and examined their sensitivity and specificity. Samples positive for SARS-CoV-2 (n = 663 + 82) were subtyped using both Sanger sequencing and five RT-qPCR melting curve analysis assays specific for the mutations N501Y, P681H, E484K, K417N/T, and N439K. The results of the two methods were compared. The training cohort and the clinical validation cohort showed equally, or significantly better sensitivity of the assays compared to the Sanger sequencing. The agreement of the Sanger sequencing and the assays ranged from 92.6 to 100% for the training cohort and 99.4-100% for the clinical validation. The sensitivity, specificity, and turn-around time of the RT-qPCR melting curve analysis assays are well-suited for clinical monitoring of VOCs, making the assays an important tool in contact tracing and risk stratification. Furthermore, the assays were able to indicate the presence of new mutations in the complementary sequence to the mutation-specific probes.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/genetics , Humans , Mutation , Reverse Transcription , SARS-CoV-2/genetics , Sensitivity and Specificity
2.
J Clin Med ; 11(1)2021 Dec 30.
Article in English | MEDLINE | ID: covidwho-1580632

ABSTRACT

C-reactive protein (CRP) has prognostic value in hospitalized patients with COVID-19; the importance of CRP in pre-hospitalized patients remains to be tested. Methods: Individuals with symptoms of COVID-19 had a SARS-CoV-2 PCR oropharyngeal swab test, and a measurement of CRP was performed at baseline, with an upper reference range of 10 mg/L. After 28 days, information about possible admissions, oxygen treatments, transfers to the ICU, or deaths was obtained from the patient files. Using logistic regression, the prognostic value of the CRP and SARS-CoV-2 test results was evaluated. Results: Among the 1006 patients included, the SARS-CoV-2 PCR test was positive in 59, and the CRP level was elevated (>10 mg/L) in 131. In total, 59 patients were hospitalized, only 3 of whom were SARS-CoV-2 positive, with elevated CRP (n = 2) and normal CRP (n = 1). The probability of being hospitalized with elevated CRP was 4.21 (95%CI 2.38-7.43, p < 0.0001), while the probability of being hospitalized with SARS-CoV-2 positivity alone was 0.85 (95%CI 0.26-2.81, p = 0.79). Conclusions: CRP is not a reliable predictor for the course of SARS-CoV-2 infection in pre-hospitalized patients. CRP, while not a SARS-CoV-2 positive test, had prognostic value in the total population of patients presenting with COVID-19-related symptoms.

4.
Nat Commun ; 12(1): 5089, 2021 08 24.
Article in English | MEDLINE | ID: covidwho-1371600

ABSTRACT

The current nucleic acid signal amplification methods for SARS-CoV-2 RNA detection heavily rely on the functions of biological enzymes which imposes stringent transportation and storage conditions, high cost and global supply shortages. Here, a non-enzymatic whole genome detection method based on a simple isothermal signal amplification approach is developed for rapid detection of SARS-CoV-2 RNA and potentially any types of nucleic acids regardless of their size. The assay, termed non-enzymatic isothermal strand displacement and amplification (NISDA), is able to quantify 10 RNA copies.µL-1. In 164 clinical oropharyngeal RNA samples, NISDA assay is 100 % specific, and it is 96.77% and 100% sensitive when setting up in the laboratory and hospital, respectively. The NISDA assay does not require RNA reverse-transcription step and is fast (<30 min), affordable, highly robust at room temperature (>1 month), isothermal (42 °C) and user-friendly, making it an excellent assay for broad-based testing.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Nucleic Acid Amplification Techniques/methods , RNA, Viral/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , COVID-19/virology , COVID-19 Testing , Humans , RNA, Viral/genetics , Recombination, Genetic
5.
J Clin Microbiol ; 59(5)2021 04 20.
Article in English | MEDLINE | ID: covidwho-1195815

ABSTRACT

Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to support clinical diagnosis and epidemiological investigations. Recently, assays for large-scale detection of total antibodies (Ab), immunoglobulin G (IgG), and IgM against SARS-CoV-2 antigens have been developed, but there are limited data on the diagnostic accuracy of these assays. This study was a Danish national collaboration and evaluated 15 commercial and one in-house anti-SARS-CoV-2 assays in 16 laboratories. Sensitivity was evaluated using 150 samples from individuals with asymptomatic, mild, or moderate COVID-19, nonhospitalized or hospitalized, confirmed by nucleic acid amplification tests (NAAT); samples were collected 13 to 73 days either from symptom onset or from positive NAAT (patients without symptoms). Specificity and cross-reactivity were evaluated in samples collected prior to the SARS-CoV-2 epidemic from >586 blood donors and patients with autoimmune diseases, cytomegalovirus or Epstein-Barr virus infections, and acute viral infections. A specificity of ≥99% was achieved by all total-Ab and IgG assays except one, DiaSorin Liaison XL IgG (97.2%). Sensitivities in descending order were Wantai ELISA total Ab (96.7%), CUH-NOVO in-house ELISA total Ab (96.0%), Ortho Vitros total Ab (95.3%), YHLO iFlash IgG (94.0%), Ortho Vitros IgG (93.3%), Siemens Atellica total Ab (93.2%), Roche Elecsys total Ab (92.7%), Abbott Architect IgG (90.0%), Abbott Alinity IgG (median 88.0%), DiaSorin Liaison XL IgG (median 84.6%), Siemens Vista total Ab (81.0%), Euroimmun/ELISA IgG (78.0%), and Snibe Maglumi IgG (median 78.0%). However, confidence intervals overlapped for several assays. The IgM results were variable, with the Wantai IgM ELISA showing the highest sensitivity (82.7%) and specificity (99%). The rate of seropositivity increased with time from symptom onset and symptom severity.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay , Cytomegalovirus Infections , Enzyme-Linked Immunosorbent Assay , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Humans , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , Laboratories , SARS-CoV-2 , Sensitivity and Specificity
6.
J Clin Microbiol ; 59(5)2021 04 20.
Article in English | MEDLINE | ID: covidwho-1081941

ABSTRACT

Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to support clinical diagnosis and epidemiological investigations. Recently, assays for large-scale detection of total antibodies (Ab), immunoglobulin G (IgG), and IgM against SARS-CoV-2 antigens have been developed, but there are limited data on the diagnostic accuracy of these assays. This study was a Danish national collaboration and evaluated 15 commercial and one in-house anti-SARS-CoV-2 assays in 16 laboratories. Sensitivity was evaluated using 150 samples from individuals with asymptomatic, mild, or moderate COVID-19, nonhospitalized or hospitalized, confirmed by nucleic acid amplification tests (NAAT); samples were collected 13 to 73 days either from symptom onset or from positive NAAT (patients without symptoms). Specificity and cross-reactivity were evaluated in samples collected prior to the SARS-CoV-2 epidemic from >586 blood donors and patients with autoimmune diseases, cytomegalovirus or Epstein-Barr virus infections, and acute viral infections. A specificity of ≥99% was achieved by all total-Ab and IgG assays except one, DiaSorin Liaison XL IgG (97.2%). Sensitivities in descending order were Wantai ELISA total Ab (96.7%), CUH-NOVO in-house ELISA total Ab (96.0%), Ortho Vitros total Ab (95.3%), YHLO iFlash IgG (94.0%), Ortho Vitros IgG (93.3%), Siemens Atellica total Ab (93.2%), Roche Elecsys total Ab (92.7%), Abbott Architect IgG (90.0%), Abbott Alinity IgG (median 88.0%), DiaSorin Liaison XL IgG (median 84.6%), Siemens Vista total Ab (81.0%), Euroimmun/ELISA IgG (78.0%), and Snibe Maglumi IgG (median 78.0%). However, confidence intervals overlapped for several assays. The IgM results were variable, with the Wantai IgM ELISA showing the highest sensitivity (82.7%) and specificity (99%). The rate of seropositivity increased with time from symptom onset and symptom severity.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay , Cytomegalovirus Infections , Enzyme-Linked Immunosorbent Assay , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Humans , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , Laboratories , SARS-CoV-2 , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL