ABSTRACT
Among outpatients with coronavirus disease 2019 (COVID-19) due to the severe acute respiratory coronavirus virus 2 (SARS-CoV-2) δ (delta) variant who did and did not receive 2 vaccine doses at 7 days after symptom onset, there was no difference in viral shedding (cycle threshold difference 0.59, 95% CI, -4.68 to 3.50; P = .77) with SARS-CoV-2 cultured from 2 (7%) of 28 and 1 (4%) of 26 outpatients, respectively.
ABSTRACT
Background: People living with chronic kidney disease (CKD) have been disproportionately affected by the coronavirus disease 2019 (COVID-19) pandemic, including higher rates of infection, hospitalization, and death. Data on responsiveness to COVID-19 vaccination strategies and immunogenicity are limited, yet required to inform vaccination strategies in this at-risk population. Objective: The objective of this study is to characterize the longitudinal serologic response to COVID-19 vaccination. Design: This is a prospective observational cohort study. Setting: Participating outpatient kidney programs within Ontario and British Columbia. Patients: Up to 2500 participants with CKD G3b-5D receiving COVID-19 vaccination, including participants receiving dialysis and kidney transplant recipients (CKD G1T-5T). Measurements: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG antibodies (anti-spike, anti-receptor binding domain, anti-nucleocapsid) will be detected by ELISA (enzyme-linked immunosorbent assay) from serum or dried blood spot testing. In a subset of participants, neutralizing antibodies against novel variants of concern will be evaluated. Peripheral blood mononuclear cells will be collected for exploratory immune profiling of SARS-CoV-2 specific cellular immunity. Methods: Participants will be recruited prior to or following any COVID-19 vaccine dose and have blood sampled for serological testing at multiple timepoints: 1, 3, 6, 9, and 12 months post vaccination. When possible, samples will be collected prior to a dose or booster. Participants will remain in the study for at least 1 year following their last COVID-19 vaccine dose. Strengths and limitations: The adaptive design of this study allows for planned modification based on emerging evidence or rapid changes in public health policy surrounding vaccination. Limitations include incomplete earlier timepoints for blood collection due to rapid vaccination of the population. Conclusions: This large multicenter serologic study of participants living with kidney disease will generate data on the kinetics of SARS-CoV-2 immune response to vaccination across the spectrum of CKD, providing insights into the amplitude and duration of immunity conferred by COVID-19 vaccination and allowing for characterization of factors associated with immune response. The results of this study may be used to inform immunization guidelines and public health recommendations for the 4 million Canadians living with CKD.
Contexte: Les personnes atteintes d'insuffisance rénale chronique (IRC) ont été touchées de façon disproportionnée par la pandémie de COVID-19 ayant notamment présenté des taux plus élevés d'infection, d'hospitalisation et de décès. Les données sur la réactivité aux stratégies de vaccination de la COVID-19 et à l'immunogénicité sont limitées, mais elles sont nécessaires pour développer des stratégies de vaccination dans cette population à risque. Objectif: Caractériser la réponse sérologique longitudinale à la vaccination contre la COVID-19. Conception: Étude de cohorte observationnelle prospective. Cadre: Les programmes ambulatoires de santé rénale participants en Ontario et en Colombie-Britannique. Sujets: Jusqu'à 2 500 personnes atteintes d'IRC G3B-5D recevant un vaccin contre la COVID-19, y compris des patients suivant des traitements de dialyse et des receveurs d'une greffe rénale (IRC G1T-5T). Mesures: Les anticorps IgG anti-SARS-CoV-2 (anti-spike, anti-domaine de liaison au récepteur, anti-nucléocapside) seront détectés par ELISA à partir du sérum ou de taches de sang séché. Un sous-groupe de sujets participera également à l'évaluation d'anticorps neutralisants dirigés contre les nouveaux variants préoccupants. Des cellules mononuclées de sang périphérique seront prélevées pour établir un profil immunitaire exploratoire de l'immunité cellulaire spécifique au SARS-CoV-2. Méthodologie: Les sujets seront recrutés avant ou après toute dose du vaccin contre la COVID-19 et se soumettront à des prélèvements sanguins pour les tests sérologiques à 1, 3, 6, 9 et 12 mois post-vaccination. Lorsque possible, des échantillons seront prélevés avant l'administration d'une dose ou d'un rappel. Les sujets demeureront dans l'étude pendant au moins un an après leur dernière dose de vaccin contre la COVID-19. Points forts et limites: La conception adaptative de l'étude permet d'apporter des modifications planifiées fondées sur de nouvelles données ou des changements rapides dans les politiques de santé publique entourant la vaccination. Les résultats sont limités par l'absence de certains prélèvements sanguins antérieurs (point temporels) en raison de la vaccination rapide de la population. Conclusion: Cette vaste étude sérologique multicentrique menée auprès de personnes atteintes de néphropathie fournira des données sur la cinétique de la réponse immunitaire à la vaccination contre le SARS-CoV-2 dans l'ensemble du spectre de l'IRC. Elle fournira des informations sur l'amplitude et la durée de l'immunité conférée par la vaccination contre la COVID-19 et permettra de caractériser les facteurs associés à la réponse immunitaire. Ces résultats serviront à orienter les recommandations de santé publique et les lignes directrices en matière d'immunisation pour les quatre millions de Canadiens et Canadiennes qui vivent avec l'IRC.
ABSTRACT
BACKGROUND: The efficacy of a single dose of pegylated interferon lambda in preventing clinical events among outpatients with acute symptomatic coronavirus disease 2019 (Covid-19) is unclear. METHODS: We conducted a randomized, controlled, adaptive platform trial involving predominantly vaccinated adults with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in Brazil and Canada. Outpatients who presented with an acute clinical condition consistent with Covid-19 within 7 days after the onset of symptoms received either pegylated interferon lambda (single subcutaneous injection, 180 µg) or placebo (single injection or oral). The primary composite outcome was hospitalization (or transfer to a tertiary hospital) or an emergency department visit (observation for >6 hours) due to Covid-19 within 28 days after randomization. RESULTS: A total of 933 patients were assigned to receive pegylated interferon lambda (2 were subsequently excluded owing to protocol deviations) and 1018 were assigned to receive placebo. Overall, 83% of the patients had been vaccinated, and during the trial, multiple SARS-CoV-2 variants had emerged. A total of 25 of 931 patients (2.7%) in the interferon group had a primary-outcome event, as compared with 57 of 1018 (5.6%) in the placebo group, a difference of 51% (relative risk, 0.49; 95% Bayesian credible interval, 0.30 to 0.76; posterior probability of superiority to placebo, >99.9%). Results were generally consistent in analyses of secondary outcomes, including time to hospitalization for Covid-19 (hazard ratio, 0.57; 95% Bayesian credible interval, 0.33 to 0.95) and Covid-19-related hospitalization or death (hazard ratio, 0.59; 95% Bayesian credible interval, 0.35 to 0.97). The effects were consistent across dominant variants and independent of vaccination status. Among patients with a high viral load at baseline, those who received pegylated interferon lambda had lower viral loads by day 7 than those who received placebo. The incidence of adverse events was similar in the two groups. CONCLUSIONS: Among predominantly vaccinated outpatients with Covid-19, the incidence of hospitalization or an emergency department visit (observation for >6 hours) was significantly lower among those who received a single dose of pegylated interferon lambda than among those who received placebo. (Funded by FastGrants and others; TOGETHER ClinicalTrials.gov number, NCT04727424.).
Subject(s)
COVID-19 Drug Treatment , COVID-19 , Interferon Lambda , Adult , Humans , Bayes Theorem , COVID-19/therapy , Double-Blind Method , Interferon Lambda/administration & dosage , Interferon Lambda/adverse effects , Interferon Lambda/therapeutic use , Polyethylene Glycols/administration & dosage , Polyethylene Glycols/adverse effects , Polyethylene Glycols/therapeutic use , SARS-CoV-2 , Treatment Outcome , Ambulatory Care , Injections, Subcutaneous , Antiviral Agents/administration & dosage , Antiviral Agents/adverse effects , Antiviral Agents/therapeutic use , COVID-19 Vaccines/therapeutic use , VaccinationABSTRACT
OBJECTIVES: SARS-CoV-2 shedding has changed as new variants have emerged. It is important to understand the trajectory of PCR positivity due to Omicron in vaccinated populations. METHODS: Double- or triple-vaccinated adult household contacts of individuals with COVID-19 self-collected oral-nasal swabs for 14 days. A hierarchical linear model estimated viral load trajectories and an exploratory logistic regression model assessed for factors associated with viral detection before symptom onset. RESULTS: Forty-one participants developed COVID-19 with 37 (90%) symptomatic. Viral load peaked 3 days after symptom onset at a median concentration of 8.83 log10 copies/milliliter (range 5.95-10.32) and the mean difference between participants with two or three COVID-19 vaccine doses was 0.02 log10 copies/milliliter (95% CI -0.13 to 0.16). PCR positivity began with a range of 4 days prior to 3 days after symptom onset and was positive on the day of symptom onset in 76% (28/37). SARS-CoV-2 detection on the day of symptom onset was less likely among those with 2 vaccine doses (OR 0.13, 95%CI 0.02-0.79). 68% (25/37) of infected participants had detectable SARS-CoV-2 with Ct<30 at 7 days after symptom onset. CONCLUSIONS: Peak viral load and duration of PCR positivity were similar in participants with COVID-19 after two versus three COVID-19 vaccine doses. Onset of viral detection relative to symptom onset was variable.
Subject(s)
COVID-19 Vaccines , COVID-19 , Adult , Humans , SARS-CoV-2 , COVID-19/prevention & control , Viral LoadABSTRACT
BACKGROUND: Widespread testing for severe acute respiratory coronavirus virus 2 (SARS-CoV-2) is necessary to curb the spread of coronavirus disease 2019 (COVID-19), but testing is undermined when the only option is a nasopharyngeal swab. Self-collected swab techniques can overcome many of the disadvantages of a nasopharyngeal swab, but they require evaluation. METHODS: Three self-collected non-nasopharyngeal swab techniques (saline gargle, oral swab and combined oral-anterior nasal swab) were compared to a nasopharyngeal swab for SARS-CoV-2 detection at multiple COVID-19 assessment centers in Toronto, Canada. The performance characteristics of each test were assessed. RESULTS: The adjusted sensitivity of the saline gargle was 0.90 (95% CI 0.86-0.94), the oral swab was 0.82 (95% CI, 0.72-0.89) and the combined oral-anterior nasal swab was 0.87 (95% CI, 0.77-0.93) compared to a nasopharyngeal swab, which demonstrated a sensitivity of Ë90% when all positive tests were the reference standard. The median cycle threshold values for the SARS-CoV-2 E-gene for concordant and discordant saline gargle specimens were 17 and 31 (P < .001), for the oral swabs these values were 17 and 28 (P < .001), and for oral-anterior nasal swabs these values were 18 and 31 (P = .007). CONCLUSIONS: Self-collected saline gargle and an oral-anterior nasal swab have a similar sensitivity to a nasopharyngeal swab for the detection of SARS-CoV-2. These alternative collection techniques are cheap and can eliminate barriers to testing, particularly in underserved populations.
Subject(s)
COVID-19 , Outpatients , Humans , Nasopharynx , SARS-CoV-2 , Saliva , Specimen HandlingABSTRACT
BACKGROUND: To date, only monoclonal antibodies have been shown to be effective for outpatients with COVID-19. Interferon lambda-1 is a type III interferon involved in innate antiviral responses with activity against respiratory pathogens. We aimed to investigate the safety and efficacy of peginterferon lambda in the treatment of outpatients with mild-to-moderate COVID-19. METHODS: In this double-blind, placebo-controlled trial, outpatients with laboratory-confirmed COVID-19 were randomly assigned to a single subcutaneous injection of peginterferon lambda 180 µg or placebo within 7 days of symptom onset or first positive swab if asymptomatic. Participants were randomly assigned (1:1) using a computer-generated randomisation list created with a randomisation schedule in blocks of four. At the time of administration, study nurses received a sealed opaque envelope with the treatment allocation number. The primary endpoint was the proportion of patients who were negative for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA on day 7 after the injection, analysed by a χ2 test following an intention-to-treat principle. Prespecified analysis of the primary endpoint, adjusted for baseline viral load, using bivariate logistic regression was done. The trial is now complete. This trial is registered with ClinicalTrials.gov, NCT04354259. FINDINGS: Between May 18, and Sept 4, 2020, we recruited 30 patients per group. The decline in SARS-CoV-2 RNA was greater in those treated with peginterferon lambda than placebo from day 3 onwards, with a difference of 2·42 log copies per mL at day 7 (p=0·0041). By day 7, 24 (80%) participants in the peginterferon lambda group had an undetectable viral load, compared with 19 (63%) in the placebo group (p=0·15). After controlling for baseline viral load, patients in the peginterferon lambda group were more likely to have undetectable virus by day 7 than were those in the placebo group (odds ratio [OR] 4·12 [95% CI 1·15-16·73; p=0·029). Of those with baseline viral load above 106 copies per mL, 15 (79%) of 19 patients in the peginterferon lambda group had undetectable virus on day 7, compared with six (38%) of 16 in the placebo group (OR 6·25 [95% CI 1·49-31·06]; p=0·012). Peginterferon lambda was well tolerated, and adverse events were similar between groups with mild and transient aminotransferase, concentration increases more frequently observed in the peginterferon lambda group. Two individuals met the threshold of grade 3 increase, one in each group, and no other grade 3 or 4 laboratory adverse events were reported. INTERPRETATION: Peginterferon lambda accelerated viral decline in outpatients with COVID-19, increasing the proportion of patients with viral clearance by day 7, particularly in those with high baseline viral load. Peginterferon lambda has potential to prevent clinical deterioration and shorten duration of viral shedding. FUNDING: The Toronto COVID-19 Action Initiative, University of Toronto, and the Ontario First COVID-19 Rapid Research Fund, Toronto General & Western Hospital Foundation.
Subject(s)
Ambulatory Care/methods , COVID-19 Drug Treatment , COVID-19 , Interleukins , Polyethylene Glycols , SARS-CoV-2 , Viral Load/drug effects , Virus Shedding/drug effects , Antiviral Agents/administration & dosage , Antiviral Agents/adverse effects , COVID-19/diagnosis , COVID-19/immunology , Double-Blind Method , Drug Monitoring/methods , Female , Humans , Intention to Treat Analysis , Interleukins/administration & dosage , Interleukins/adverse effects , Male , Middle Aged , Polyethylene Glycols/administration & dosage , Polyethylene Glycols/adverse effects , RNA, Viral/isolation & purification , SARS-CoV-2/isolation & purification , SARS-CoV-2/physiology , Severity of Illness Index , Treatment OutcomeABSTRACT
BACKGROUND: Point-of-care tests (POCT) are promising tools to detect SARS-CoV-2 in specific settings. Initial reports suggest the ID NOW™ COVID-19 assay (Abbott Diagnostics Inc, USA) is less sensitive than standard real-time reverse transcription polymerase chain reaction (rRT-PCR) assays. This has raised concern over false negatives in SARS-CoV-2 POCT. OBJECTIVES: We compared the performance of the ID NOW™ COVID-19 assay to our in-house rRT-PCR assay to assess whether dry swabs used in ID NOW™ testing could be stored in transport media and be re-tested by rRT-PCR for redundancy and to provide material for further investigation. METHODS: Paired respiratory swabs collected from patients at three acute care hospitals were used. One swab in transport media (McMaster Molecular Media (MMM)) was tested for SARS-CoV-2 by a laboratory-developed two-target rRT-PCR assay. The second was stored dry in a sterile container and tested by the ID NOW™ COVID-19 assay. Following ID NOW™ testing, dry swabs were stored in MMM for up to 48 h and re-tested by rRT-PCR. Serially diluted SARS-CoV-2 particles were used to assess the impact of heat inactivation and storage time. RESULTS: Respiratory swabs (n = 343) from 179 individuals were included. Using rRT-PCR results as the comparator, the ID NOW™ COVID-19 assay had positive (PPA) and negative (NPA) percent agreements of 87.0% (95% CI:0.74-0.94) and 99.7% (95% CI:0.98-0.99). Re-tested swabs placed in MMM following ID NOW testing had PPA and NPA of 88.8% (95% CI:0.76-0.95) and 99.7% (95% CI:0.98-0.99), respectively. CONCLUSIONS: Storing spent dry swabs in transport media for redundancy rRT-PCR testing is a potential approach to address possible false negatives with the ID NOW™ COVID-19 assay.
Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Point-of-Care Testing , Sensitivity and Specificity , Specimen HandlingABSTRACT
To compare sensitivity of specimens for COVID-19 diagnosis, we tested 151 nasopharyngeal/midturbinate swab pairs from 117 COVID-19 inpatients using reverse-transcriptase polymerase chain reaction (RT-PCR). Sensitivity was 94% for nasopharyngeal and 75% for midturbinate swabs (P = .0001). In 88 nasopharyngeal/midturbinate pairs with matched saliva, sensitivity was 86% for nasopharyngeal swabs and 88% for combined midturbinate swabs/saliva.
Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Nasopharynx , Saliva , Specimen HandlingABSTRACT
Widely available and easily accessible testing for COVID-19 is a cornerstone of pandemic containment strategies. Nasopharyngeal swabs (NPS) are the currently accepted standard for sample collection but are limited by their need for collection devices and sampling by trained healthcare professionals. The aim of this study was to compare the performance of saliva to NPS in an outpatient setting. This was a prospective study conducted at three centers, which compared the performance of saliva and NPS samples collected at the time of assessment center visit. Samples were tested by real-time reverse transcription polymerase chain reaction and sensitivity and overall agreement determined between saliva and NPS. Clinical data was abstracted by chart review for select study participants. Of the 432 paired samples, 46 were positive for SARS-CoV-2, with seven discordant observed between the two sample types (four individuals testing positive only by NPS and three by saliva only). The observed agreement was 98.4% (kappa coefficient 0.91) and a composite reference standard demonstrated sensitivity of 0.91 and 0.93 for saliva and NPS samples, respectively. On average, the Ct values obtained from saliva as compared to NPS were higher by 2.76. This study demonstrates that saliva performs comparably to NPS for the detection of SARS-CoV-2. Saliva was simple to collect, did not require transport media, and could be tested with equipment readily available at most laboratories. The use of saliva as an acceptable alternative to NPS could support the use of widespread surveillance testing for SARS-CoV-2.