Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Clin Microbiol ; 59(5)2021 04 20.
Article in English | MEDLINE | ID: covidwho-1195815

ABSTRACT

Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to support clinical diagnosis and epidemiological investigations. Recently, assays for large-scale detection of total antibodies (Ab), immunoglobulin G (IgG), and IgM against SARS-CoV-2 antigens have been developed, but there are limited data on the diagnostic accuracy of these assays. This study was a Danish national collaboration and evaluated 15 commercial and one in-house anti-SARS-CoV-2 assays in 16 laboratories. Sensitivity was evaluated using 150 samples from individuals with asymptomatic, mild, or moderate COVID-19, nonhospitalized or hospitalized, confirmed by nucleic acid amplification tests (NAAT); samples were collected 13 to 73 days either from symptom onset or from positive NAAT (patients without symptoms). Specificity and cross-reactivity were evaluated in samples collected prior to the SARS-CoV-2 epidemic from >586 blood donors and patients with autoimmune diseases, cytomegalovirus or Epstein-Barr virus infections, and acute viral infections. A specificity of ≥99% was achieved by all total-Ab and IgG assays except one, DiaSorin Liaison XL IgG (97.2%). Sensitivities in descending order were Wantai ELISA total Ab (96.7%), CUH-NOVO in-house ELISA total Ab (96.0%), Ortho Vitros total Ab (95.3%), YHLO iFlash IgG (94.0%), Ortho Vitros IgG (93.3%), Siemens Atellica total Ab (93.2%), Roche Elecsys total Ab (92.7%), Abbott Architect IgG (90.0%), Abbott Alinity IgG (median 88.0%), DiaSorin Liaison XL IgG (median 84.6%), Siemens Vista total Ab (81.0%), Euroimmun/ELISA IgG (78.0%), and Snibe Maglumi IgG (median 78.0%). However, confidence intervals overlapped for several assays. The IgM results were variable, with the Wantai IgM ELISA showing the highest sensitivity (82.7%) and specificity (99%). The rate of seropositivity increased with time from symptom onset and symptom severity.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay , Cytomegalovirus Infections , Enzyme-Linked Immunosorbent Assay , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Humans , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , Laboratories , SARS-CoV-2 , Sensitivity and Specificity
2.
J Clin Microbiol ; 59(5)2021 04 20.
Article in English | MEDLINE | ID: covidwho-1081941

ABSTRACT

Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to support clinical diagnosis and epidemiological investigations. Recently, assays for large-scale detection of total antibodies (Ab), immunoglobulin G (IgG), and IgM against SARS-CoV-2 antigens have been developed, but there are limited data on the diagnostic accuracy of these assays. This study was a Danish national collaboration and evaluated 15 commercial and one in-house anti-SARS-CoV-2 assays in 16 laboratories. Sensitivity was evaluated using 150 samples from individuals with asymptomatic, mild, or moderate COVID-19, nonhospitalized or hospitalized, confirmed by nucleic acid amplification tests (NAAT); samples were collected 13 to 73 days either from symptom onset or from positive NAAT (patients without symptoms). Specificity and cross-reactivity were evaluated in samples collected prior to the SARS-CoV-2 epidemic from >586 blood donors and patients with autoimmune diseases, cytomegalovirus or Epstein-Barr virus infections, and acute viral infections. A specificity of ≥99% was achieved by all total-Ab and IgG assays except one, DiaSorin Liaison XL IgG (97.2%). Sensitivities in descending order were Wantai ELISA total Ab (96.7%), CUH-NOVO in-house ELISA total Ab (96.0%), Ortho Vitros total Ab (95.3%), YHLO iFlash IgG (94.0%), Ortho Vitros IgG (93.3%), Siemens Atellica total Ab (93.2%), Roche Elecsys total Ab (92.7%), Abbott Architect IgG (90.0%), Abbott Alinity IgG (median 88.0%), DiaSorin Liaison XL IgG (median 84.6%), Siemens Vista total Ab (81.0%), Euroimmun/ELISA IgG (78.0%), and Snibe Maglumi IgG (median 78.0%). However, confidence intervals overlapped for several assays. The IgM results were variable, with the Wantai IgM ELISA showing the highest sensitivity (82.7%) and specificity (99%). The rate of seropositivity increased with time from symptom onset and symptom severity.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay , Cytomegalovirus Infections , Enzyme-Linked Immunosorbent Assay , Epstein-Barr Virus Infections , Herpesvirus 4, Human , Humans , Immunoglobulin G/isolation & purification , Immunoglobulin M/isolation & purification , Laboratories , SARS-CoV-2 , Sensitivity and Specificity
3.
Lancet Infect Dis ; 20(12): 1401-1408, 2020 12.
Article in English | MEDLINE | ID: covidwho-1009965

ABSTRACT

BACKGROUND: Health-care workers are thought to be highly exposed to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. We aimed to investigate the prevalence of antibodies against SARS-CoV-2 in health-care workers and the proportion of seroconverted health-care workers with previous symptoms of COVID-19. METHODS: In this observational cohort study, screening was offered to health-care workers in the Capital Region of Denmark, including medical, nursing, and other students who were associated with hospitals in the region. Screening included point-of-care tests for IgM and IgG antibodies against SARS-CoV-2. Test results and participant characteristics were recorded. Results were compared with findings in blood donors in the Capital Region in the study period. FINDINGS: Between April 15 and April 23, 2020, we screened 29 295 health-care workers, of whom 28 792 (98·28%) provided their test results. We identified 1163 (4·04% [95% CI 3·82-4·27]) seropositive health-care workers. Seroprevalence was higher in health-care workers than in blood donors (142 [3·04%] of 4672; risk ratio [RR] 1·33 [95% CI 1·12-1·58]; p<0·001). Seroprevalence was higher in male health-care workers (331 [5·45%] of 6077) than in female health-care workers (832 [3·66%] of 22 715; RR 1·49 [1·31-1·68]; p<0·001). Frontline health-care workers working in hospitals had a significantly higher seroprevalence (779 [4·55%] of 16 356) than health-care workers in other settings (384 [3·29%] of 11 657; RR 1·38 [1·22-1·56]; p<0·001). Health-care workers working on dedicated COVID-19 wards (95 [7·19%] of 1321) had a significantly higher seroprevalence than other frontline health-care workers working in hospitals (696 [4·35%] of 15 983; RR 1·65 [1·34-2·03]; p<0·001). 622 [53·5%] of 1163 seropositive participants reported symptoms attributable to SARS-CoV-2. Loss of taste or smell was the symptom that was most strongly associated with seropositivity (377 [32·39%] of 1164 participants with this symptom were seropositive vs 786 [2·84%] of 27 628 without this symptom; RR 11·38 [10·22-12·68]). The study is registered at ClinicalTrials.gov, NCT04346186. INTERPRETATION: The prevalence of health-care workers with antibodies against SARS-CoV-2 was low but higher than in blood donors. The risk of SARS-CoV-2 infection in health-care workers was related to exposure to infected patients. More than half of seropositive health-care workers reported symptoms attributable to COVID-19. FUNDING: Lundbeck Foundation.


Subject(s)
COVID-19/epidemiology , Health Personnel/statistics & numerical data , Occupational Health/statistics & numerical data , Adult , Antibodies, Viral/blood , Blood Donors/statistics & numerical data , COVID-19/diagnosis , COVID-19/immunology , COVID-19/pathology , Cohort Studies , Denmark/epidemiology , Female , Health Personnel/classification , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Point-of-Care Testing , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Seroconversion , Seroepidemiologic Studies
SELECTION OF CITATIONS
SEARCH DETAIL