ABSTRACT
OBJECTIVE: Cadaveric simulations have shown endonasal drilling and cautery generate aerosols, which is a significant concern for otolaryngologists during the COVID-19 era. This study quantifies aerosol generation during routine rhinologic surgeries and in-office procedures in live patients. METHODS: Aerosols ranging from 0.30 to 10.0 µm were measured in real-time using an optical particle sizer during surgeries and in-office procedures. Various mask conditions were tested during rigid nasal endoscopy (RNE) and postoperative debridement (POD). RESULTS: Higher aerosol concentrations (AC) ranging from 2.69 to 10.0 µm were measured during RNE (n = 9) with no mask vs two mask conditions (P = .002 and P = .017). Mean AC (0.30-10.0 µm) were significantly higher during POD (n = 9) for no mask vs a mask covering the patient's mouth condition (mean difference = 0.16 ± 0.03 particles/cm3, 95% CI 0.10-0.22, P < .001). There were no discernible spikes in aerosol levels during endoscopic septoplasty (n = 3). Aerosol spikes were measured in two of three functional endoscopic sinus surgeries (FESS) with microdebrider. Using suction mitigation, there were no discernible spikes during powered drilling in two anterior skull base surgeries (ASBS). CONCLUSION: Use of a surgical mask over the patient's mouth during in-office procedures or a mask with a slit for an endoscope during RNE significantly diminished aerosol generation. However, whether this reduction in aerosol generation is sufficient to prevent transmission of communicable diseases via aerosols was beyond the scope of this study. There were several spikes in aerosols during FESS and ASBS, though none were associated with endonasal drilling with the use of suction mitigation. LEVEL OF EVIDENCE: 4.
ABSTRACT
OBJECTIVE: The symptoms and long-term sequelae of SARS-CoV-2 infection have yet to be determined, and evaluating possible early signs is critical to determine which patients should be tested and treated. The objective of this ongoing study is to evaluate initial and short-term rhinologic symptoms, olfactory ability, and general quality of life in patients undergoing SARS-CoV-2 testing. STUDY DESIGN: Prospective case-control. SETTING: Academic institute. METHODS: Adult patients tested for SARS-CoV-2 were prospectively enrolled and separated into positive and negative groups. Each participant completed 4 validated patient-reported outcome measures. The UPSIT (University of Pennsylvania Smell Identification Test) was distributed to patients who were SARS-CoV-2 positive. RESULTS: The positive group reported significantly decreased sense of smell and taste on the 22-item Sinonasal Outcome Test (SNOT-22) as compared with the negative group (mean ± SD: 3.4 ± 1.7 vs 1.2 ± 1.4, P < .001). The positive group had a much higher probability of reporting a decrease in smell/taste as "severe" or "as bad as it can be" (63.3% vs 5.8%) with an odds ratio of 27.6 (95% CI, 5.9-128.8). There were no differences between groups for overall SNOT-22 domain scores, PHQ-4 depression/anxiety (Patient Health Questionnaire-4), and 5-Level EQ-5D quality-of-life scores. Mean Self-MOQ (Self-reported Mini Olfactory Questionnaire) scores were 7.0 ± 5.6 for the positive group and 1.8 ± 4.0 for the negative group (P < .001). The mean UPSIT score was 28.8 ± 7.2 in the positive group. CONCLUSION: Symptomatic patients who are SARS-CoV-2 positive report severe olfactory and gustatory dysfunction via the Self-MOQ and SNOT-22 as compared with symptomatic patients testing negative.
ABSTRACT
PURPOSE: The COVID-19 pandemic has led to concerns over transmission risk from healthcare procedures, especially when operating in the head and neck such as during surgical repair of facial fractures. This study aims to quantify aerosol and droplet generation from mandibular and midface open fixation and measure mitigation of airborne particles by a smoke evacuating electrocautery hand piece. MATERIALS AND METHODS: The soft tissue of the bilateral mandible and midface of two fresh frozen cadaveric specimens was infiltrated using a 0.1% fluorescein solution. Surgical fixation via oral vestibular approach was performed on each of these sites. Droplet splatter on the surgeon's chest, facemask, and up to 198.12 cm (6.5 ft) away from each surgical site was measured against a blue background under ultraviolet-A (UV-A) light. Aerosol generation was measured using an optical particle sizer. RESULTS: No visible droplet contamination was observed for any trials of mandible or midface fixation. Total aerosolized particle counts from 0.300-10.000 µm were increased compared to baseline following each use of standard electrocautery (n = 4, p < 0.001) but not with use of a suction evacuating electrocautery hand piece (n = 4, p = 0.103). Total particle counts were also increased during use of the powered drill (n = 8, p < 0.001). CONCLUSIONS: Risk from visible droplets during mandible and midface fixation is low. However, significant increases in aerosolized particles were measured after electrocautery use and during powered drilling. Aerosol dispersion is significantly decreased with the use of a smoke evacuating electrocautery hand piece.
Subject(s)
Aerosols/adverse effects , COVID-19/transmission , Disease Transmission, Infectious/statistics & numerical data , Intraoperative Period , Pandemics , SARS-CoV-2 , COVID-19/epidemiology , Humans , Mandible , United States/epidemiologyABSTRACT
To provide data on risk of respiratory droplets from common otolaryngologic procedures during the COVID-19 pandemic, a novel simulation of droplet exposure from flexible laryngoscopy was performed. After completion of a nasal symptom questionnaire, topical fluorescein spray was administered into the nasal and oropharynx of 10 healthy volunteers, who then underwent flexible laryngoscopy under 2 conditions: routine without provoked response and with prompted sneeze/cough. After each, droplets on the proceduralist and participant were counted under ultraviolet A light. Droplets were observed on 1 of 10 volunteers after routine laryngoscopy and 4 of 10 during laryngoscopy with sneeze/cough. A nasal symptom score based on congestion and rhinorrhea was significantly elevated among droplet producers after sneeze/cough (P = .0164). No droplets were observed on the provider. Overall, with adequate personal protective equipment, flexible laryngoscopy poses minimal droplet risk to providers. Nasal symptoms can identify patients more likely to produce droplets after sneeze/cough.
Subject(s)
COVID-19/epidemiology , Disease Transmission, Infectious/prevention & control , Health Personnel , Laryngoscopy/adverse effects , Otorhinolaryngologic Diseases/diagnosis , Pandemics , SARS-CoV-2 , COVID-19/transmission , Comorbidity , Humans , Otorhinolaryngologic Diseases/epidemiology , Otorhinolaryngologic Diseases/therapyABSTRACT
OBJECTIVE: After significant restrictions initially due to the COVID-19 pandemic, otolaryngologists have begun resuming normal clinical practice. However, the risk of SARS-CoV-2 transmission to health care workers through aerosolization and airborne transmission during rhinologic surgery remains incompletely characterized. The objective of this study was to quantify the number concentrations of aerosols generated during rhinologic surgery with and without interventions involving 3 passive suction devices. STUDY DESIGN: Cadaver simulation. SETTING: Dedicated surgical laboratory. SUBJECTS AND METHODS: In a simulation of rhinologic procedures with and without different passive suction interventions, the concentrations of generated aerosols in the particle size range of 0.30 to 10.0 µm were quantified with an optical particle sizer. RESULTS: Functional endoscopic sinus surgery with and without microdebrider, high-speed powered drilling, use of an ultrasonic aspirator, and electrocautery all produced statistically significant increases in concentrations of aerosols of various sizes (P < .05). Powered drilling, ultrasonic aspirator, and electrocautery generated the highest concentration of aerosols, predominantly submicroparticles <1 µm. All interventions with a suction device were effective in reducing aerosols, though the surgical smoke evacuation system was the most effective passive suction method in 2 of the 5 surgical conditions with statistical significance (P < .05). CONCLUSION: Significant aerosol concentrations were produced in the range of 0.30 to 10.0 µm during all rhinologic procedures in this cadaver simulation. Rhinologic surgery with a passive suction device results in significant mitigation of generated aerosols.
Subject(s)
Aerosols , COVID-19/transmission , Nasal Surgical Procedures/adverse effects , COVID-19/prevention & control , Cadaver , Humans , Models, BiologicalABSTRACT
BACKGROUND: The coronavirus disease (COVID-19) is the latest pandemic of the digital age. With the internet harvesting large amounts of data from the general population in real time, public databases such as Google Trends (GT) and the Baidu Index (BI) can be an expedient tool to assist public health efforts. OBJECTIVE: The aim of this study is to apply digital epidemiology to the current COVID-19 pandemic to determine the utility of providing adjunctive epidemiologic information on outbreaks of this disease and evaluate this methodology in the case of future pandemics. METHODS: An epidemiologic time series analysis of online search trends relating to the COVID-19 pandemic was performed from January 9, 2020, to April 6, 2020. BI was used to obtain online search data for China, while GT was used for worldwide data, the countries of Italy and Spain, and the US states of New York and Washington. These data were compared to real-world confirmed cases and deaths of COVID-19. Chronologic patterns were assessed in relation to disease patterns, significant events, and media reports. RESULTS: Worldwide search terms for shortness of breath, anosmia, dysgeusia and ageusia, headache, chest pain, and sneezing had strong correlations (r>0.60, P<.001) to both new daily confirmed cases and deaths from COVID-19. GT COVID-19 (search term) and GT coronavirus (virus) searches predated real-world confirmed cases by 12 days (r=0.85, SD 0.10 and r=0.76, SD 0.09, respectively, P<.001). Searches for symptoms of diarrhea, fever, shortness of breath, cough, nasal obstruction, and rhinorrhea all had a negative lag greater than 1 week compared to new daily cases, while searches for anosmia and dysgeusia peaked worldwide and in China with positive lags of 5 days and 6 weeks, respectively, corresponding with widespread media coverage of these symptoms in COVID-19. CONCLUSIONS: This study demonstrates the utility of digital epidemiology in providing helpful surveillance data of disease outbreaks like COVID-19. Although certain online search trends for this disease were influenced by media coverage, many search terms reflected clinical manifestations of the disease and showed strong correlations with real-world cases and deaths.