Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
APMIS ; 131(3): 128-132, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2231536

ABSTRACT

In Denmark, vaccination against Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) has been with the Pfizer-BioNTech (BTN162b2) or the Moderna (mRNA-1273) mRNA vaccines. Patients with chronic hepatitis C virus (HCV) infection followed in our clinic received mRNA vaccinations according to the Danish roll-out vaccination plan. To monitor HCV infection, RNA was extracted from patient plasma and RNA sequencing was performed on the Illumina platform. In 10 of 108 HCV patient samples, full-length or traces of SARS-CoV-2 spike mRNA vaccine sequences were found in blood up to 28 days after COVID-19 vaccination. Detection of mRNA vaccine sequences in blood after vaccination adds important knowledge regarding this technology and should lead to further research into the design of lipid-nanoparticles and the half-life of these and mRNA vaccines in humans.


Subject(s)
COVID-19 , Hepatitis C, Chronic , Hepatitis C , Humans , COVID-19 Vaccines , SARS-CoV-2/genetics , COVID-19/prevention & control , Vaccination , Hepacivirus , Antibodies, Viral
2.
iScience ; 26(2): 105949, 2023 Feb 17.
Article in English | MEDLINE | ID: covidwho-2179842

ABSTRACT

Vaccines have relieved the public health burden of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), and globally inactivated vaccines are most widely used. However, poor vaccination accessibility and waning immunity maintain the pandemic, driving emergence of variants. We developed an inactivated SARS-CoV-2 (I-SARS-CoV-2) vaccine based on a viral isolate with the Spike mutation D614G, produced in Vero cells in a scalable bioreactor, inactivated with ß-propiolactone, purified by membrane-based steric exclusion chromatography, and adjuvanted with MF59-like adjuvant AddaVax. I-SARS-CoV-2 and a derived split vaccine induced persisting neutralizing antibodies in mice; moreover, lyophilized antigen was immunogenic. Following homologous challenge, I-SARS-CoV-2 immunized hamsters were protected against disease and lung pathology. In contrast with reports for widely used vaccines, hamster plasma similarly neutralized the homologous and the Delta (B.1.617.2) variant viruses, whereas the Omicron (B.1.1.529) variant was neutralized less efficiently. Applied bioprocessing approaches offer advantages regarding scalability and production, potentially benefitting worldwide vaccine coverage.

3.
J Clin Virol ; 153: 105214, 2022 08.
Article in English | MEDLINE | ID: covidwho-1945516

ABSTRACT

BACKGROUND: The SARS-CoV-2 pandemic has resulted in massive testing by Rapid Antigen Tests (RAT) without solid independent data regarding clinical performance being available. Thus, decision on purchase of a specific RAT may rely on manufacturer-provided data and limited peer-reviewed data. METHODS: This study consists of two parts. In the retrospective analytical part, 33 RAT from 25 manufacturers were compared to RT-PCR on 100 negative and 204 positive deep oropharyngeal cavity samples divided into four groups based on RT-PCR Cq levels. In the prospective clinical part, nearly 200 individuals positive for SARS-CoV-2 and nearly 200 individuals negative for SARS-CoV-2 by routine RT-PCR testing were retested within 72 h for each of 44 included RAT from 26 manufacturers applying RT-PCR as the reference method. RESULTS: The overall analytical sensitivity differed significantly between the 33 included RAT; from 2.5% (95% CI 0.5-4.8) to 42% (95% CI 35-49). All RAT presented analytical specificities of 100%. Likewise, the overall clinical sensitivity varied significantly between the 44 included RAT; from 2.5% (95% CI 0.5-4.8) to 94% (95% CI 91-97). All RAT presented clinical specificities between 98 and 100%. CONCLUSION: The study presents analytical as well as clinical performance data for 44 commercially available RAT compared to the same RT-PCR test. The study enables identification of individual RAT that has significantly higher sensitivity than other included RAT and may aid decision makers in selecting between the included RAT. FUNDING: The study was funded by a participant fee for each test and the Danish Regions.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques/methods , Humans , Prospective Studies , Retrospective Studies , SARS-CoV-2/genetics , Sensitivity and Specificity
4.
JMIR Res Protoc ; 11(5): e35706, 2022 May 04.
Article in English | MEDLINE | ID: covidwho-1834187

ABSTRACT

BACKGROUND: The SARS-CoV-2 pandemic has resulted in an unprecedented level of worldwide testing for epidemiologic and diagnostic purposes, and due to the extreme need for tests, the gold-standard Reverse Transcription Polymerase Chain Reaction (RT-PCR) testing capacity has been unable to meet the overall worldwide testing demand. Consequently, although the current literature has shown the sensitivity of rapid antigen tests (RATs) to be inferior to RT-PCR, RATs have been implemented on a large scale without solid data on performance. OBJECTIVE: This study will compare analytical and clinical sensitivities and specificities of 50 lateral flow- or laboratory-based RATs and 3 strand invasion-based amplification (SIBA)-RT-PCR tests from 30 manufacturers to RT-PCR testing of samples obtained from the deep oropharynx. In addition, the study will compare sensitivities and specificities of the included RATs as well as RT-PCR on clinical samples obtained from the deep oropharynx, the anterior nasal cavity, saliva, the deep nasopharynx, and expired air to RT-PCR on deep oropharyngeal samples. METHODS: In the prospective part of the study, 200 individuals found SARS-CoV-2 positive and 200 individuals found SARS-CoV-2 negative by routine RT-PCR testing will be retested with each RAT, applying RT-PCR as the reference method. In the retrospective part of the study, 304 deep oropharyngeal cavity swabs divided into 4 groups based on RT-PCR quantification cycle (Cq) levels will be tested with each RAT. RESULTS: The results will be reported in several papers with different aims. The first paper will report retrospective (analytical sensitivity, overall and stratified into different Cq range groups) and prospective (clinical sensitivity) data for RATs, with RT-PCR as the reference method. The second paper will report results for RAT based on anatomical sampling location. The third paper will compare different anatomical sampling locations by RT-PCR testing. The fourth paper will focus on RATs that rely on central laboratory testing. Tests from 4 different manufacturers will be compared for analytical performance data on retrospective deep oropharyngeal swab samples. The fifth paper will report the results of 4 RATs applied both as professional use and as self-tests. The last paper will report the results from 2 breath tests in the study. A comparison of sensitivity and specificity between RATs will be conducted using the McNemar test for paired samples and the chi-squared test for unpaired samples. Comparison of the positive predictive value (PPV) and negative predictive value (NPV) between RATs will be performed by the bootstrap test, and 95% CIs for sensitivity, specificity, PPV, and NPV will be calculated as bootstrap CIs. CONCLUSIONS: The study will compare the sensitivities of a large number of RATs for SARS-CoV-2 to with those of RT-PCR and will address whether lateral flow-based RATs differ significantly from laboratory-based RATs. The anatomical test locations for both RATs and RT-PCR will also be compared. TRIAL REGISTRATION: ClinicalTrials.gov NCT04913116; https://clinicaltrials.gov/ct2/show/NCT04913116. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/35706.

5.
Euro Surveill ; 27(10)2022 03.
Article in English | MEDLINE | ID: covidwho-1742167

ABSTRACT

Following emergence of the SARS-CoV-2 variant Omicron in November 2021, the dominant BA.1 sub-lineage was replaced by the BA.2 sub-lineage in Denmark. We analysed the first 2,623 BA.2 cases from 29 November 2021 to 2 January 2022. No epidemiological or clinical differences were found between individuals infected with BA.1 versus BA.2. Phylogenetic analyses showed a geographic east-to-west transmission of BA.2 from the Capital Region with clusters expanding after the Christmas holidays. Mutational analysis shows distinct differences between BA.1 and BA.2.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Denmark/epidemiology , Humans , Molecular Epidemiology , Phylogeny , SARS-CoV-2/genetics
6.
Sci Rep ; 11(1): 22214, 2021 11 15.
Article in English | MEDLINE | ID: covidwho-1517639

ABSTRACT

Rapid nucleic-acid based tests that can be performed by non-professionals outside laboratory settings could help the containment of the pandemic SARS-CoV-2 virus and may potentially prevent further widespread lockdowns. Here, we present a novel compact portable detection instrument (the Egoo Health System) for extraction-free detection of SARS-CoV-2 using isothermal reverse transcription strand invasion based amplification (RT-SIBA). The SARS-CoV-2 RT-SIBA assay can be performed directly on crude oropharyngeal swabs without nucleic acid extraction with a reaction time of 30 min. The Egoo Health system uses a capsule system, which is automatically sealed tight in the Egoo instrument after applying the sample, resulting in a closed system optimal for molecular isothermal amplification. The performance of the Egoo Health System is comparable to the PCR instrument with an analytical sensitivity of 25 viral RNA copies per SARS-CoV-2 RT-SIBA reaction and a clinical sensitivity and specificity between 87.0-98.4% and 96.6-98.2% respectively.


Subject(s)
COVID-19/diagnosis , COVID-19/epidemiology , Equipment Design , Molecular Diagnostic Techniques/instrumentation , Molecular Diagnostic Techniques/methods , Pandemics/prevention & control , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/virology , Cell Phone , Humans , Mobile Applications , Oropharynx/virology , Point-of-Care Testing , Polymorphism, Single Nucleotide , RNA, Viral/genetics , Retrospective Studies , Sensitivity and Specificity
7.
Euro Surveill ; 25(44)2020 11.
Article in English | MEDLINE | ID: covidwho-1110208

ABSTRACT

BackgroundPoint-of-care tests (POCT) for influenza A and B viruses and respiratory syncytial virus (RSV) were implemented in emergency departments of all hospitals in the Capital Region of Denmark in 2018.AimTo establish whether POC testing for influenza viruses or RSV is based on a valid respiratory symptom indication, whether changes in patient management based on a positive result are safe and whether syndromic POC testing may benefit patients with influenza or RSV.MethodsSamples from 180 children (< 18 years) and 375 adults tested using POCT between February and July 2018 were retested for 26 respiratory pathogens. Diagnosis, indication for POC testing, hospitalisation time, antimicrobial therapy and readmission or death within one month of testing were obtained from patient records.ResultsA valid indication for POC testing was established in 168 (93.3%) of children and 334 (89.1%) of adults. A positive POCT result significantly reduced antibiotic prescription and median hospitalisation time by 44.3 hours for adults and 14.2 hours for children, and significantly increased antiviral treatment in adults. Risk of readmission or death was not significantly altered by a positive result. Testing for 26 respiratory pathogens established that risk of coinfection is lower with increasing age and that POCT for adults should be restricted to the influenza and RSV season.ConclusionPositive POCT resulted in changed patient management for both children and adults, and was deemed safe. POCT for additional pathogens may be beneficial in children below 5 years of age and outside the influenza and RSV season.


Subject(s)
Emergency Service, Hospital , Influenza A virus , Influenza B virus , Influenza, Human , Point-of-Care Testing , Respiratory Syncytial Virus Infections , Respiratory Syncytial Viruses , Adolescent , Adult , Aged , Child , Child, Preschool , Denmark/epidemiology , Female , Humans , Infant , Infant, Newborn , Influenza A virus/isolation & purification , Influenza B virus/isolation & purification , Influenza, Human/diagnosis , Influenza, Human/epidemiology , Influenza, Human/therapy , Male , Middle Aged , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus Infections/epidemiology , Respiratory Syncytial Virus Infections/therapy , Respiratory Syncytial Viruses/isolation & purification , Risk Assessment , Young Adult
8.
J Clin Microbiol ; 58(5)2020 04 23.
Article in English | MEDLINE | ID: covidwho-209223

ABSTRACT

The QIAstat-Dx Respiratory Panel (QIAstat-Dx RP) is a multiplex in vitro diagnostic test for the qualitative detection of 20 pathogens directly from nasopharyngeal swab (NPS) specimens. The assay is performed using a simple sample-to-answer platform with results available in approximately 69 min. The pathogens identified are adenovirus, coronavirus 229E, coronavirus HKU1, coronavirus NL63, coronavirus OC43, human metapneumovirus A and B, influenza A, influenza A H1, influenza A H3, influenza A H1N1/2009, influenza B, parainfluenza virus 1, parainfluenza virus 2, parainfluenza virus 3, parainfluenza virus 4, rhinovirus/enterovirus, respiratory syncytial virus A and B, Bordetella pertussis, Chlamydophila pneumoniae, and Mycoplasma pneumoniae This multicenter evaluation provides data obtained from 1,994 prospectively collected and 310 retrospectively collected (archived) NPS specimens with performance compared to that of the BioFire FilmArray Respiratory Panel, version 1.7. The overall percent agreement between QIAstat-Dx RP and the comparator testing was 99.5%. In the prospective cohort, the QIAstat-Dx RP demonstrated a positive percent agreement of 94.0% or greater for the detection of all but four analytes: coronaviruses 229E, NL63, and OC43 and rhinovirus/enterovirus. The test also demonstrated a negative percent agreement of ≥97.9% for all analytes. The QIAstat-Dx RP is a robust and accurate assay for rapid, comprehensive testing for respiratory pathogens.


Subject(s)
Bacteria/isolation & purification , Molecular Diagnostic Techniques/methods , Multiplex Polymerase Chain Reaction/methods , Nasopharynx/microbiology , Nasopharynx/virology , Viruses/isolation & purification , Bacterial Infections/diagnosis , Bacterial Infections/microbiology , Humans , Molecular Diagnostic Techniques/instrumentation , Multiplex Polymerase Chain Reaction/instrumentation , Prospective Studies , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/microbiology , Respiratory Tract Infections/virology , Retrospective Studies , Virus Diseases/diagnosis , Virus Diseases/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL