1.
Critical Reviews in Environmental Science and Technology ; 53(6):733-753, 2023.
Article in English | Scopus | ID: covidwho-2239235

ABSTRACT

Far UV-C, informally defined as electromagnetic radiation with wavelengths between 200 and 230 nm, has characteristics that are well-suited to control of airborne pathogens. Specifically, Far UV-C has been shown to be highly effective for inactivation of airborne pathogens;yet this same radiation has minimal potential to cause damage to human skin and eye tissues. Critically, unlike UV-B, Far UV-C radiation does not substantially penetrate the dead cell layer of skin (stratum corneum) and does not reach germinative cells in the basal layer. Similarly, Far UV-C radiation does not substantially penetrate through corneal epithelium of the eye, thereby preventing exposure of germinative cells within the eye. The most common source of Far UV-C radiation is the krypton chloride excimer (KrCl*) lamp, which has a primary emission centered at 222 nm. Ozone production from KrCl* lamps is modest, such that control of indoor ozone from these systems can be accomplished easily using conventional ventilation systems. This set of characteristics offers the potential for Far UV-C devices to be used in occupied spaces, thereby allowing for improved effectiveness for inactivation of airborne pathogens, including those that are responsible for COVID-19. © 2022 The Author(s). Published with license by Taylor & Francis Group, LLC.

2.
J Hosp Infect ; 132: 85-92, 2023 Feb.
Article in English | MEDLINE | ID: covidwho-2229414

ABSTRACT

Ultraviolet (UV)-C light for disinfection has experienced a surge in popularity since the outbreak of COVID-19. Currently, many different UV-C systems, with varied properties that impact disinfection performance, are available on the market. Therefore this review aims to bundle the available information on UV-C disinfection to obtain an overview of its advantages, disadvantages, and performance-influencing parameters. A literature search was performed using the snowball search method in Google Scholar and PubMed with the following keywords: UV-C disinfection, UV-C dose, UV-C light source, UV-C repair mechanism, UV-C photoreactivation, and UV-C disinfection standards. The main parameters of UV-C disinfection are wavelength, dose, relative humidity, and temperature. There is no consensus about their optimal values, but, in general, light at a high dose and a spectrum of wavelengths containing 260 nm is preferred in an environment at room temperature with low relative humidity. This light can be generated by mercury-vapour, light-emitting diode (LED), pulsed-xenon, or excimer lamps. Multiple factors are detrimental to disinfection performance such as shadowing, a rough surface topography, a high level of contamination, repair mechanisms, and the lack of standardization. Also, there are health and safety risks associated with the UV-C technology when used in the proximity of people. UV-C disinfection systems have promising features and the potential to improve in the future. However, clarifications surrounding the different parameters influencing the technologies' effectiveness in hospital environment are needed. Therefore UV-C disinfection should currently be considered for low-level rather than high-level disinfection.


Subject(s)
COVID-19 , Humans , COVID-19/prevention & control , Ultraviolet Rays , Hospitals , Disinfection/methods , Temperature
3.
Gondwana Res ; 2022 Aug 02.
Article in English | MEDLINE | ID: covidwho-2232142

ABSTRACT

The high rate of transmission of the COVID-19 virus has brought various types of disinfection techniques, for instance, hydrogen peroxide vaporization, microwave generating steam, UV radiation, and dry heating, etc. to prevent the further transmission of the virus. The chemical-based techniques are predominantly used for sanitization of hands, buildings, hospitals, etc. However, these chemicals may affect the health of humans and the environment in unexplored aspects. Furthermore, the UV lamp-based radiation sanitization technique had been applied but has not gained larger acceptability owing to its limitation to penetrate different materials. Therefore, the optical properties of materials are especially important for the utilization of UV light on such disinfection applications. The germicidal or microorganism inactivation application of UV-C has only been in-use in a closed chamber, due to its harmful effect on human skin and the eye. However, it is essential to optimize UV for its use in an open environment for a larger benefit to mitigate the virus spread. In view of this, far UV-C (222nm) based technology has emerged as a potential option for the sanitization in open areas and degradation of microorganisms present in aerosol during the working conditions. Hence, in the present review article, efforts have been made to evaluate the technical aspects of UV (under the different spectrum and wavelength ranges) and the control of COVID 19 virus spread in the atmosphere including the possibilities of the human body sanitization in working condition.

4.
J Hosp Infect ; 2023 Feb 06.
Article in English | MEDLINE | ID: covidwho-2220982

ABSTRACT

BACKGROUND: UV light emitting diodes (UV-LEDs) are energy efficient and of special interest for the inactivation of microorganisms. In context of the current pandemic, novel UV technologies can offer a powerful alternative of effective infection prevention and control (IPC). METHODS: We here assessed the antimicrobial efficacy of UV-C LEDs on Escherichia coli, Pseudomonas fluorescens and Listeria innocua as well as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), human immunodeficiency virus 1 (HIV-1) and murine norovirus (MNV) dried on inanimate surfaces based on the European standard EN 17272. RESULTS: We found an inactivation rate of 90% for the tested bacteria at a mean UV-C dose, averaged over all three investigated UV-C wavelengths, of 1.7 mJ cm-2 for E. coli, 1.9 mJ cm-2 for P. fluorescens and 1.5 mJ cm-2 for L. innocua. For the tested viruses, a 90% inactivation rate at UV doses less than 15 mJ cm-2 for applied UV wavelengths at 255 nm and 265 nm were found. Exposure of viruses to longer UV wavelengths such as 275 nm and 285 nm, required much higher doses up to 120 mJ cm-2 for inactivation. Regarding inactivation, non-enveloped MNV required much higher UV doses for all tested wavelengths compared to SARS-CoV-2 or HIV-1. CONCLUSION: Overall, our data recommend the use of LEDs emitting at shorter wavelengths of the UV-C spectrum to inactivate bacteria as well as enveloped and non-enveloped viruses by exposure to the appropriate UV-dose. However, low availability and excessive production costs of shortwave UV-C LEDs restricts the implementation currently and supports the use of longwave UV-C LEDs in combination with higher irradiation doses.

5.
2nd IEEE Mysore Sub Section International Conference, MysuruCon 2022 ; 2022.
Article in English | Scopus | ID: covidwho-2192041
6.
6th International Conference on Advanced Production and Industrial Engineering , ICAPIE 2021 ; : 261-272, 2023.
Article in English | Scopus | ID: covidwho-2173870
7.
Appl Biosaf ; 28(1): 1-10, 2023 Mar 01.
Article in English | MEDLINE | ID: covidwho-2188046

ABSTRACT

Introduction: The widespread transmission of the SARS-CoV-2 virus has increased scientific and societal interest in air cleaning technologies, and their potential to mitigate the airborne spread of microorganisms. Here we evaluate room scale use of five mobile air cleaning devices. Methods: A selection of air cleaners, containing high efficiency filtration, was tested using an airborne bacteriophage challenge. Assessments of bioaerosol removal efficacy were undertaken using a decay measurement approach over 3 h, with air cleaner performance compared with bioaerosol decay rate without an air cleaner in the sealed test room. Evidence of chemical by-product emission was also checked, as were total particle counts. Results: Bioaerosol reduction, exceeding natural decay, was observed for all air cleaners. Reductions ranged between devices from <2-log per m3 room air for the least effective, to a >5-log reduction for the most efficacious systems. One system generated detectable ozone within the sealed test room, but ozone was undetectable when the system was run in a normally ventilated room. Total particulate air removal trends aligned with measured airborne bacteriophage decline. Discussion: Air cleaner performance differed, and this could relate to individual air cleaner flow specifications as well as test room conditions, such as air mixing during testing. However, measurable reductions in bioaerosols, beyond natural airborne decay rate, were observed. Conclusion: Under the described test conditions, air cleaners containing high efficiency filtration significantly reduced bioaerosol levels. The best performing air cleaners could be investigated further with improved assay sensitivity, to enable measurement of lower residual levels of bioaerosols.

8.
Adv Eng Softw ; 175: 103330, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2122264

ABSTRACT

The COVID-19 pandemic made robot manufacturers explore the idea of combining mobile robotics with UV-C light to automate the disinfection processes. But performing this process in an optimum way introduces some challenges: on the one hand, it is necessary to guarantee that all surfaces receive the radiation level to ensure the disinfection; at the same time, it is necessary to minimize the radiation dose to avoid the damage of the environment. In this work, both challenges are addressed with the design of a complete coverage path planning (CCPP) algorithm. To do it, a novel architecture that combines the glasius bio-inspired neural network (GBNN), a motion strategy, an UV-C estimator, a speed controller, and a pure pursuit controller have been designed. One of the main issues in CCPP is the deadlocks. In this application they may cause a loss of the operation, lack of regularity and high peaks in the radiation dose map, and in the worst case, they can make the robot to get stuck and not complete the disinfection process. To tackle this problem, in this work we propose a preventive deadlock processing algorithm (PDPA) and an escape route generator algorithm (ERGA). Simulation results show how the application of PDPA and the ERGA allow to complete complex maps in an efficient way where the application of GBNN is not enough. Indeed, a 58% more of covered surface is observed. Furthermore, two different motion strategies have been compared: boustrophedon and spiral motion, to check its influence on the performance of the robot navigation.

9.
J Photochem Photobiol ; 12: 100151, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2120218

ABSTRACT

Objective: We report on the development and characterization of a UV-C (λ  =  200 - 280 nm, λpeak = 254 nm) chamber designed for the rapid disinfection of N95 class filtering-facepiece respirators contaminated with SARS-CoV-2 coronaviruses. The device was evaluated against Betacoronavirus strain MHV-3 and its virucidal capacity was evaluated as a function of different applied UV-C doses (UV-C exposure times of 60 s, 120 s, 180 s, and 240 s) using two types of respirators geometry (shell and two-panel shapes, 3M 8801 H and 9920 H, respectively), at eight points of the respirators. Background: Most chemical disinfection methods are not recommended for N95 masks. UV-C light provided by UVGI lamps (254 nm) is an effective physical agent against viruses and bacteria due to direct photochemical harming effect on DNA/RNA, and can provide rapid disinfection for personal protective equipment such as N95/PFF2 masks. Results: The device reached a mean elimination rate of 99.9999% of MHV-3 inoculated into all the assessed different points on the tested PFF2 respirator models in a UV-C cycle of just 60 s. Statistical analysis performed through Person´s chi-square test showed no correlation between the viral infectivity reduction and the viral inoculation point (p = 0.512) and the tested respirator models (p = 0.556). However, a correlation was found between the exposure time and the viral infectivity reduction (p = 0.000*), between UV-C and no UV-C exposure. All the tested UV-C exposure times (60 s, 120 s, 180 s, and 240 s) provided the same reduction in infection rates. Therefore, 60 s was confirmed as the minimum exposure time to achieve a 99.9999% or 6 Log reduction in MHV-3 coronavirus infection rates in the PFF2 samples tested in the device. Conclusions: We conclude that the assessed UV-C chamber for the inactivation of MHV-3 coronavirus in N95/PFF2 standard masks can be a promising tool for effective and rapid disinfection of coronaviruses, including SARS-CoV-2 virus.

10.
2nd International Congress on Advances in Mechanical and Systems Engineering, CAMSE 2021 ; : 157-164, 2023.
Article in English | Scopus | ID: covidwho-2059746
11.
6th International Conference on System-Integrated Intelligence, SysInt 2022 ; 546 LNNS:116-125, 2023.
Article in English | Scopus | ID: covidwho-2048151
12.
Indoor Air ; 32(9): e13115, 2022 09.
Article in English | MEDLINE | ID: covidwho-2042837

ABSTRACT

Surface residing SARS-CoV-2 is efficiently inactivated by UV-C irradiation. This raises the question whether UV-C-based technologies are also suitable to decontaminate SARS-CoV-2- containing aerosols and which doses are needed to achieve inactivation. Here, we designed a test bench to generate aerosolized SARS-CoV-2 and exposed the aerosols to a defined UV-C dose. Our results demonstrate that the exposure of aerosolized SARS-CoV-2 with a low average dose in the order of 0.42-0.51 mJ/cm2 UV-C at 254 nm resulted in more than 99.9% reduction in viral titers. Altogether, UV-C-based decontamination of aerosols seems highly effective to achieve a significant reduction in SARS-CoV-2 infectivity.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , Respiratory Aerosols and Droplets , SARS-CoV-2 , Ultraviolet Rays
13.
Frontiers of Environmental Science & Engineering ; 17(3), 2023.
Article in English | ProQuest Central | ID: covidwho-2027649
14.
Photochem Photobiol Sci ; 2022 Aug 26.
Article in English | MEDLINE | ID: covidwho-2014667

ABSTRACT

SARS-CoV-2 remains infectious for several hours on surfaces. It can be inactivated by UV-C irradiation but optimal conditions for rapid inactivation, especially on non-plastic surfaces remains unclear. A SARS-CoV-2 inoculum was irradiated with a UV-C LED (265 nm) or a UV-C mercury lamp (254 nm). Infectivity titers (TCID50/mL) and inactivation rates were then quantified on plastic, steel, tissue, paper and cardboard surfaces. We demonstrated that efficient SARS-CoV-2 inactivation (> 99.999% on plastic and steel, ≥ 99.8% on tissue, paper and cardboard) can be achieved by both a UV-C mercury lamp and a UV-C LED after 30 s of irradiations at 3 cm, corresponding to UV-C doses of 92.85 and 44.7 mJ/cm2, respectively. Inactivation on a plastic surface was more efficient with the mercury UV-C lamp (p < 0.005). The mercury UV-C lamp could be more relevant than the LED in high-risk settings, such as medical care or research laboratories.

15.
Environ Sci Technol ; 56(17): 12424-12430, 2022 09 06.
Article in English | MEDLINE | ID: covidwho-2000844

ABSTRACT

Behavioral and medical control measures have not been effective in containing the spread of SARS-CoV-2 in large part due to the unwillingness of populations to adhere to "best practices". Ultraviolet light with wavelengths of between 200 and 280 nm (UV-C) and, in particular, germicidal ultraviolet light, which refers to wavelengths around 254 nm, have the potential to unobtrusively reduce the risk of SARS-CoV-2 transmission in enclosed spaces. We investigated the effectiveness of a strategy using UV-C light to prevent airborne transmission of the virus in a hamster model. Treatment of environmental air with 254 nm UV-C light prevented transmission of SARS-CoV-2 between individuals in a model using highly susceptible Syrian golden hamsters. The prevention of transmission of SARS-CoV-2 in a natural system by treating elements of the surrounding environment is one more weapon in the arsenal to combat COVID. The results presented indicate that coupling mitigation strategies utilizing UV-C light, along with current methods to reduce transmission risk, have the potential to allow a return to normal indoor activities.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Cricetinae , Humans , Respiratory Aerosols and Droplets , Ultraviolet Rays
16.
J Photochem Photobiol ; 11: 100138, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1977553

ABSTRACT

SARS-CoV-2 is responsible for the COVID-19 pandemic, which has caused almost 570 million infections and over six million deaths worldwide. To help curb its spread, solutions using ultraviolet light (UV) for quick virus inactivation inside buildings without human intervention could be very useful to reduce chances of contagion. The UV dose must be sufficient to inactivate the virus considering the different materials in the room, but it should not be too high, not to degrade the environment. In the present study, we have analyzed the ability of a 254 nm wavelength UV-C lamp to inactivate dried samples of SARS-CoV-2 exposed at a distance of two meters, simulating a full-scale scenario. Our results showed that virus inactivation was extremely efficient in most tested materials, which included plastic, metal, wood, and textile, with a UV-C exposure of only 42 s (equivalent to 10 mJ/cm2). However, porous materials like medium density fibreboard, were hard to decontaminate, indicating that they should be avoided in hospital rooms and public places.

17.
11th International Conference on Informatics, Environment, Energy and Applications, IEEA 2022 ; : 25-29, 2022.
Article in English | Scopus | ID: covidwho-1973912
18.
2022 IEEE International Conference on Plasma Science, ICOPS 2022 ; 2022-May, 2022.
Article in English | Scopus | ID: covidwho-1961396
19.
J Photochem Photobiol B ; 234: 112531, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1956241

ABSTRACT

The SARS-CoV-2 pandemic emphasized effective cleaning and disinfection of common spaces as an essential tool to mitigate viral transmission. To address this problem, decontamination technologies based on UV-C light are being used. Our aim was to generate coherent and translational datasets of effective UV-C-based SARS-CoV-2 inactivation protocols for the application on surfaces with different compositions. Virus infectivity after UV-C exposure of several porous (bed linen, various types of upholstery, synthetic leather, clothing) and non-porous (types of plastic, stainless steel, glass, ceramics, wood, vinyl) materials was assessed through plaque assay using a SARS-CoV-2 clinical isolate. Studies were conducted under controlled environmental conditions with a 254-nm UV-C lamp and irradiance values quantified using a 254 nm-calibrated sensor. From each material type (porous/non-porous), a product was selected as a reference to assess the decrease of infectious virus particles as a function of UV-C dose, before testing the remaining surfaces with selected critical doses. Our data show that UV-C irradiation is effectively inactivating SARS-CoV-2 on both material types. However, an efficient reduction in the number of infectious viral particles was achieved much faster and at lower doses on non-porous surfaces. The treatment effectiveness on porous surfaces was demonstrated to be highly variable and composition-dependent. Our findings will support the optimization of UV-C-based technologies, enabling the adoption of effective customizable protocols that will help to ensure higher antiviral efficiencies.


Subject(s)
COVID-19 , SARS-CoV-2 , Disinfection/methods , Humans , Pandemics , Ultraviolet Rays , Virus Inactivation
20.
Food Control ; 142: 109271, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-1936421

ABSTRACT

Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), the cause of the COVID-19 outbreaks, is transmitted by respiratory droplets and has become a life-threatening viral pandemic worldwide. The aim of this study was to evaluate the effects of different chemical (chlorine dioxide [ClO2] and peroxyacetic acid [PAA]) and physical (ultraviolet [UV]-C irradiation) inactivation methods on various food-contact surfaces (stainless steel [SS] and polypropylene [PP]) and foods (lettuce, chicken breast, and salmon) contaminated with human coronavirus 229E (HCoV-229E). Treatments with the maximum concentration of ClO2 (500 ppm) and PAA (200 ppm) for 5 min achieved >99.9% inactivation on SS and PP. At 200 ppm ClO2 for 1 min on lettuce, chicken breast, and salmon, the HCoV-229E titers were 1.19, 3.54, and 3.97 log10 TCID50/mL, respectively. Exposure (5 min) to 80 ppm PAA achieved 1.68 log10 reduction on lettuce, and 2.03 and 1.43 log10 reductions on chicken breast and salmon, respectively, treated with 1500 ppm PAA. In the carrier tests, HCoV-229E titers on food-contact surfaces were significantly decreased (p < 0.05) with increased doses of UV-C (0-60 mJ/cm2) and not detected at the maximum UV-C dose (Detection limit: 1.0 log10 TCID50/coupon). The UV-C dose of 900 mJ/cm2 proved more effective on chicken breast (>2 log10 reduction) than on lettuce and salmon (>1 log10 reduction). However, there were no quality changes (p > 0.05) in food samples after inactivation treatments except the maximum PAA concentration (5 min) and the UV-C dose (1800 mJ/cm2).

SELECTION OF CITATIONS