Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
ERS Monograph ; 2022(96):122-141, 2022.
Article in English | EMBASE | ID: covidwho-2315675
2.
Respiratory Care ; 68(4):i, 2023.
Article in English | EMBASE | ID: covidwho-2291367
3.
European Respiratory Journal Conference: European Respiratory Society International Congress, ERS ; 60(Supplement 66), 2022.
Article in English | EMBASE | ID: covidwho-2282699
4.
J Allergy Clin Immunol Pract ; 10(6): 1474-1484, 2022 06.
Article in English | MEDLINE | ID: covidwho-1878213

ABSTRACT

The COVID-19 pandemic has placed increased demands on the ability to safely perform pulmonary procedures in keeping with Centers for Disease Control and Prevention (CDC), American Thoracic Society (ATS), and the Occupational Safety and Health Administration (OSHA) recommendations. Accordingly, the American Academy of Allergy, Asthma & Immunology (AAAAI) Asthma Diagnosis and Treatment convened this work group to offer guidance. The work group is composed of specialist practitioners from academic and both large and small practices. Individuals with special expertise were assigned sections on spirometry, fractional exhaled nitric oxide, nebulized treatments, and methacholine challenge. The work group met periodically to achieve consensus. This resulting document has recommendations for the allergy/asthma/immunology health care setting based on available evidence including reference documents from the CDC, ATS, and OSHA.


Subject(s)
Asthma , COVID-19 , Hypersensitivity , Asthma/diagnosis , Asthma/epidemiology , Asthma/therapy , Breath Tests/methods , Exhalation , Humans , Nitric Oxide , Pandemics/prevention & control , Spirometry
5.
Respir Care ; 67(8): 899-905, 2022 08.
Article in English | MEDLINE | ID: covidwho-1863113

ABSTRACT

BACKGROUND: Methacholine challenge testing (MCT) is a common bronchoprovocation technique used to assess airway hyper-responsiveness. We previously demonstrated that the addition of a viral filter to the nebulizer exhalation limb substantially reduced expelled particles during MCT. Our aim was to evaluate whether this modification affects the delivered dose of methacholine. METHODS: A mechanical ventilator was connected to a lung simulator with breathing frequency 15 breaths/min, tidal volume 500 mL, inspiratory-expiratory ratio 1:1, with a sinusoidal waveform. We compared methacholine dose delivery using the Hudson Micro Mist or AeroEclipse II BAN nebulizers powered by either a dry gas source or a compressor system. A filter placed in line between the nebulizer and test lung was weighed before and after 1 min of nebulized methacholine delivery. Mean inhaled mass was measured with and without a viral filter on the exhalation limb. Dose delivery was calculated by multiplying the mean inhaled mass by the respirable fraction (particles < 5 µm) and inhalation time. Unpaired t test was used to compare methacholine dose delivery with and without viral filter placement. RESULTS: The addition of a viral filter did not significantly affect methacholine dose delivery across all devices tested. Using a 50-psi dry gas source, dose delivered with or without a viral filter did not differ with the Hudson (422.3 µg vs 282.0 µg, P = .11) or the AeroEclipse nebulizer (563.0 µg vs 657.6 µg, P = .59). Using the compressor, dose delivered with and without a viral filter did not differ with the Hudson (974.0 µg vs 868.0 µg, P = .03) or the AeroEclipse nebulizer (818.0 µg vs 628.5 µg, P = .42). CONCLUSIONS: The addition of a viral filter to the nebulizer exhalation limb did not affect methacholine dose during bronchoprovocation testing. Routine use of a viral filter should be considered to improve pulmonary function technician safety and infection control measures during the ongoing COVID-19 pandemic.


Subject(s)
COVID-19 , Exhalation , Administration, Inhalation , Aerosols , Albuterol , Bronchodilator Agents , Equipment Design , Humans , Methacholine Chloride , Nebulizers and Vaporizers , Pandemics
6.
Respir Care ; 66(12): 1858-1865, 2021 12.
Article in English | MEDLINE | ID: covidwho-1524338

ABSTRACT

BACKGROUND: Methacholine bronchoprovocation or challenge testing (MCT) is commonly performed to assess airway hyper-responsiveness in the setting of suspected asthma. Nebulization is an aerosol-generating procedure, but little is known about the risks of MCT in the context of the ongoing coronavirus disease 2019 (COVID-19) pandemic. We aimed to quantify and characterize aerosol generation during MCT by using different delivery methods and to assess the impact of adding a viral filter. METHODS: Seven healthy subjects performed simulated MCT in a near particle-free laboratory space with 4 different nebulizers and with a dosimeter. Two devices continuously sampled the ambient air during the procedure, which detected ultrafine particles, from 0.02-1 µm, and particles of sizes 0.3, 0.5, 1.0, 2.0, 5.0, and 10 µm, respectively. Particle generation was compared among all the devices, with and without viral filter placement. RESULTS: Ultrafine-particle generation during simulated MCT was significant across all the devices. Ultrafine-particle (0.02-1 µm) concentrations decreased 77%-91% with the addition of a viral filter and varied significantly between unfiltered (P < .001) and filtered devices (P < .001). Ultrafine-particle generation was lowest when using the dosimeter with filtered Hudson nebulizer (1,258 ± 1,644 particle/mL). Ultrafine-particle concentrations with the filtered nebulizer devices using a compressor were higher than particle concentrations detected when using the dosimeter: Monaghan (3,472 ± 1,794 particles/mL), PARI (4,403 ± 2,948), Hudson (6,320 ± 1,787) and AirLife (9,523 ± 5,098). CONCLUSIONS: The high particle concentrations generated during MCT pose significant infection control concerns during the COVID-19 pandemic. Particle generation during MCT was significantly reduced by using breath-actuated delivery and a viral filter, which offers an effective mitigation strategy.


Subject(s)
COVID-19 , Pandemics , Aerosols , Humans , Infection Control , Methacholine Chloride , Nebulizers and Vaporizers , Particle Size , SARS-CoV-2
7.
Biosens Bioelectron ; 190: 113439, 2021 Oct 15.
Article in English | MEDLINE | ID: covidwho-1267613

ABSTRACT

The methacholine challenge test is considered to be the gold standard bronchoprovocation test used to diagnose asthma, and this test is always performed in pulmonary function labs or doctors' offices. Methacholine (MCH) acts by inducing airway tightening/bronchoconstriction, and more importantly, MCH is hydrolyzed by cholinesterase enzyme (ChE). Recently, the American Thoracic Society raised concerns about pulmonary function testing during the COVID-19 pandemic due to recently reported correlation between cholinesterase and COVID-19 pneumonia severity/mortality, and it was shown that cholinesterase levels are reduced in the acute phase of severe COVID-19 pneumonia. This work describes the microfabrication of potentiometric sensors using copper as the substrate and chemically polymerized graphene nanocomposites as the transducing layer for tracking the kinetics of MCH enzymatic degradation in real blood samples. The in-vitro estimation of the characteristic parameters of the MCH metabolism [Michaelis-Menten constant (Km) and reaction velocity (Vmax)] were found to be 241.041 µM and 56.8 µM/min, respectively. The proposed sensor is designed to be used as a companion diagnostic device that can (i) answer questions about patient eligibility to perform methacholine challenge tests, (ii) individualize/personalize medical dosing of methacholine, (iii) provide portable and inexpensive devices allowing automated readouts without the need for operator intervention (iv) recommend therapeutic interventions including intensive care during early stages and reflecting the disease state of COVID-19 pneumonia. We hope that this methacholine electrochemical sensor will help in assaying ChE activity in a "timely" manner and predict the severity and prognosis of COVID-19 to improve treatment outcomes and decrease mortality.


Subject(s)
Biosensing Techniques , COVID-19 , Bronchoconstrictor Agents , Humans , Methacholine Chloride , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL