Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 660
Filter
1.
J Dent Res ; : 220345231169434, 2023 May 29.
Article in English | MEDLINE | ID: covidwho-20236300

ABSTRACT

The COVID-19 pandemic has escalated the risk of SARS-CoV-2 transmission in the dental practice, especially as droplet-aerosol particles are generated by high-speed instruments. This has heightened awareness of other orally transmitted viruses, including influenza and herpes simplex virus 1 (HSV1), which are capable of threatening life and impairing health. While current disinfection procedures commonly use surface wipe-downs to reduce viral transmission, they are not fully effective. Consequently, this provides the opportunity for a spectrum of emitted viruses to reside airborne for hours and upon surfaces for days. The objective of this study was to develop an experimental platform to identify a safe and effective virucide with the ability to rapidly destroy oral viruses transported within droplets and aerosols. Our test method employed mixing viruses and virucides in a fine-mist bottle atomizer to mimic the generation of oral droplet-aerosols. The results revealed that human betacoronavirus OC43 (related to SARS-CoV-2), human influenza virus (H1N1), and HSV1 from atomizer-produced droplet-aerosols were each fully destroyed by only 100 ppm of hypochlorous acid (HOCl) within 30 s, which was the shortest time point of exposure to the virucide. Importantly, 100 ppm HOCl introduced into the oral cavity is known to be safe for humans. In conclusion, this frontline approach establishes the potential of using 100 ppm HOCl in waterlines to continuously irrigate the oral cavity during dental procedures to expeditiously destroy harmful viruses transmitted within aerosols and droplets to protect practitioners, staff, and other patients.

2.
Children (Basel) ; 10(5)2023 May 19.
Article in English | MEDLINE | ID: covidwho-20233623

ABSTRACT

PURPOSE: During the COVID-19 pandemic, the use of salivary swabs (SS) to detect the SARS-CoV-2 virus has been implemented and widely studied in adults and children. However, the role of SS in detecting other common respiratory viruses in children is poorly investigated. METHODS: Children younger than 18 years of age admitted with respiratory signs and symptoms underwent both nasopharyngeal and SS procedures. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of SS were calculated, considering the nasopharyngeal swab result as the gold standard. RESULTS: A total of 83 patients (44 females, 53%) underwent both nasopharyngeal and SS procedures. Overall, the sensitivity of SS was 49.4%. Sensitivity according to different respiratory viruses ranged from 0% to 71.43%, while the specificity ranged from 96% to 100%. Negative predictive value ranged from 68.06% to 98.8%, while positive predictive value ranged from 0 to 100%. SS sensitivity in patients younger than 12 months of age was 39.47%, while in patients older than or equal to 12 months of age it was 57.78%. Patients with negative SS had a significantly lower median age (8.5 months (15.25) vs. 23 months (34), p = 0.001) and a significantly lower quantity of median saliva collected for salivary analysis (0 µL (213) vs. 300 µL (100), p < 0.001). CONCLUSIONS: SS has a relatively low sensitivity in detecting common respiratory viruses in children with LRTI, with a lower probability in younger children (and in particular those younger than 6 months of age) or those from whom we have collected lesser amounts of saliva. New strategies to improve saliva collection are needed for testing on a larger study population.

3.
Int J Mol Sci ; 24(11)2023 Jun 03.
Article in English | MEDLINE | ID: covidwho-20233198

ABSTRACT

In this study, the intrinsic surface-enhanced Raman spectroscopy (SERS)-based approach coupled with chemometric analysis was adopted to establish the biochemical fingerprint of SARS-CoV-2 infected human fluids: saliva and nasopharyngeal swabs. The numerical methods, partial least squares discriminant analysis (PLS-DA) and support vector machine classification (SVMC), facilitated the spectroscopic identification of the viral-specific molecules, molecular changes, and distinct physiological signatures of pathetically altered fluids. Next, we developed the reliable classification model for fast identification and differentiation of negative CoV(-) and positive CoV(+) groups. The PLS-DA calibration model was described by a great statistical value-RMSEC and RMSECV below 0.3 and R2cal at the level of ~0.7 for both type of body fluids. The calculated diagnostic parameters for SVMC and PLS-DA at the stage of preparation of calibration model and classification of external samples simulating real diagnostic conditions evinced high accuracy, sensitivity, and specificity for saliva specimens. Here, we outlined the significant role of neopterin as the biomarker in the prediction of COVID-19 infection from nasopharyngeal swab. We also observed the increased content of nucleic acids of DNA/RNA and proteins such as ferritin as well as specific immunoglobulins. The developed SERS for SARS-CoV-2 approach allows: (i) fast, simple and non-invasive collection of analyzed specimens; (ii) fast response with the time of analysis below 15 min, and (iii) sensitive and reliable SERS-based screening of COVID-19 disease.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , Saliva/chemistry , Nasopharynx , RNA, Viral/genetics , Spectrum Analysis, Raman , Specimen Handling/methods , COVID-19 Testing
4.
Journal of Public Health in Africa ; 14(S2) (no pagination), 2023.
Article in English | EMBASE | ID: covidwho-20239380

ABSTRACT

Background. Surveys on Public Knowledge, Attitude, and Practice (PKAP) have been conducted in various countries with respondents from the public as well as health workers. Measuring the knowledge of the public about COVID-19 is very important to determine the knowledge gap among the public and also as an evaluation of the preventive efforts for COVID-19. Objective. The purpose of this research was to determine whether education level is a factor that affects one's literacy about COVID-19. Materials and Methods. This is cross-sectional research with online-based data collection using the Kobo toolbox application. The data collection was carried out from the 19th of April until the 2nd of May 2020. The number of people under study is 792. The level of knowledge was measured using 12 research questions with true or false question types. the multivariable logistic regression was carried out. Results. Most of the respondents (52.5%) were in the young age group (15-35 years old), were male (57.3%), and had a bache-lor or diploma education level (62.1%). Furthermore, most of the respondents had good knowledge (65.4%). The higher the respon-dents' educational level means, the better knowledge they had concerning COVID-19 (P=0.013). Conclusions. Public knowledge about COVID-19 is affected by their level of education. A good level of knowledge about COVID-19 was found among respondents with master's and doctoral degrees. This finding can contribute to the prevention of COVID-19, in which the priority of educating communities about COVID-19 should be given to those having an educational level below a master's degree.Copyright © the Author(s), 2023.

5.
Indian Journal of Medical Microbiology ; 45 (no pagination), 2023.
Article in English | EMBASE | ID: covidwho-20232484

ABSTRACT

Purpose: Compared to nasopharyngeal/oropharyngeal swabs (N/OPS-VTM), non-invasive saliva samples have enormous potential for scalability and routine population screening of SARS-CoV-2. In this study, we investigate the efficacy of saliva samples relative to N/OPS-VTM for use as a direct source for RT-PCR based SARS-CoV-2 detection. Method(s): We collected paired nasopharyngeal/oropharyngeal swabs and saliva samples from suspected positive SARS-CoV-2 patients and tested using RT-PCR. We used generalized linear models to investigate factors that explain result agreement. Further, we used simulations to evaluate the effectiveness of saliva-based screening in restricting the spread of infection in a large campus such as an educational institution. Result(s): We observed a 75.4% agreement between saliva and N/OPS-VTM, that increased drastically to 83% in samples stored for less than three days. Such samples processed within two days of collection showed 74.5% test sensitivity. Our simulations suggest that a test with 75% sensitivity, but high daily capacity can be very effective in limiting the size of infection clusters in a workspace. Guided by these results, we successfully implemented a saliva-based screening in the Bangalore Life Sciences Cluster (BLiSC) campus. Conclusion(s): These results suggest that saliva may be a viable alternate source for SARS-CoV-2 surveillance if samples are processed immediately. Although saliva shows slightly lower sensitivity levels when compared to N/OPS-VTM, saliva collection is logistically advantageous. We strongly recommend the implementation of saliva-based screening strategies for large workplaces and in schools, as well as for population-level screening and routine surveillance as we learn to live with the SARS-CoV-2 virus.Copyright © 2023 Indian Association of Medical Microbiologists

6.
Biosens Bioelectron ; 237: 115457, 2023 Jun 08.
Article in English | MEDLINE | ID: covidwho-20245261

ABSTRACT

Sensitive and anti-interference detection of targeted signal(s) in body fluids is one of the paramount tasks in biosensing. Overcoming the complication and high cost of antibody/aptamer-modification, surface-enhanced Raman spectroscopy (SERS) based on antibody/aptamer-free (AAF) substrates has shown great promise, yet with rather limited detection sensitivity. Herein, we report ultrasensitive and anti-interference detection of SARS-CoV-2 spike protein in untreated saliva by an AAF SERS substrate, applying the evanescent field induced by the high-order waveguide modes of well-defined nanorods for SERS for the first time. A detection limit of 3.6 × 10-17 M and 1.6 × 10-16 M are obtained in phosphate buffered saline and untreated saliva, respectively; the detection limits are three orders of magnitude improved than the best records from AAF substrates. This work unlocks an exciting path to design AAF SERS substrates for ultrasensitive biosensing, not limited to detection of viral antigens.

7.
Mater Today Chem ; 30: 101597, 2023 Jun.
Article in English | MEDLINE | ID: covidwho-20230762

ABSTRACT

SARS-CoV-2 rapid spread required urgent, accurate, and prompt diagnosis to control the virus dissemination and pandemic management. Several sensors were developed using different biorecognition elements to obtain high specificity and sensitivity. However, the task to achieve these parameters in combination with fast detection, simplicity, and portability to identify the biorecognition element even in low concentration remains a challenge. Therefore, we developed an electrochemical biosensor based on polypyrrole nanotubes coupled via Ni(OH)2 ligation to an engineered antigen-binding fragment of heavy chain-only antibodies (VHH) termed Sb#15. Herein we report Sb#15-His6 expression, purification, and characterization of its interaction with the receptor-binding domain (RBD) of SARS-CoV-2 in addition to the construction and validation of a biosensor. The recombinant Sb#15 is correctly folded and interacts with the RBD with a dissociation constant (KD) of 27.1 ± 6.4 nmol/L. The biosensing platform was developed using polypyrrole nanotubes and Ni(OH)2, which can properly orientate the immobilization of Sb#15-His6 at the electrode surface through His-tag interaction for the sensitive SARS-CoV-2 antigen detection. The quantification limit was determined as 0.01 pg/mL using recombinant RBD, which was expressively lower than commercial monoclonal antibodies. In pre-characterized saliva, both Omicron and Delta SARS-CoV-2 were accurately detected only in positive samples, meeting all the requirements recommended by the World Health Organization for in vitro diagnostics. A low sample volume of saliva is needed to perform the detection, providing results within 15 min without further sample preparations. In summary, a new perspective allying recombinant VHHs with biosensor development and real sample detection was explored, addressing the need for accurate, rapid, and sensitive biosensors.

8.
Microchemical Journal ; : 108933, 2023.
Article in English | ScienceDirect | ID: covidwho-20230746

ABSTRACT

Interleukin-10 (IL-10) is an anti-inflammatory cytokine that is secreted in response to an acute phase inflammation in patients who are suffering from heart failure (HF). The aim of this work was to develop an electrochemical biosensor for determining salivary IL-10 levels. Biofunctionalization strategy was improved through the use of copper-free click chemistry for the developed sensor due to its advantages, leading to high quantitative yields of stable triazoles, rapid reaction, no cytotoxic Cu(I) catalyst requirement, and high specificity of cyclooctynes toward azides. The approach involved in binding of dibenzocyclooctyne acid (DBCO-COOH) to thiol-azide assembled gold microelectrodes, later capturing the monoclonal IL-10 antibody (IL-10 mAb), and ultimately allowing direct detection of IL-10 antigen. Fourier transform infrared spectroscopy (FTIR) and nanoplotter associated with fluorescence microscopy methods have been employed to analyze and prove the biofunctionalization of the gold microelectrodes. Moreover, the electrochemical impedance spectroscopy (EIS) technique was used for detecting IL-10 antigen. The developed immunosensor showed a semi-logarithmic linear range, from 0.1 pg/mL to 5 pg/mL with R2 = 0.9815 and a limit of quantitation (LOQ) of 0.1 pg/mL with relative standard deviation (RSD) of 10.67%. The specificity of the immunosensor was evaluated using an inflammatory cytokine, and none of it generated detectable EIS signals. Finally, the successful analysis of saliva samples from a healthy volunteer without Coronavirus (COVID-19) infection demonstrated the usefulness of the developed immunosensor.

9.
J Clin Virol ; 165: 105496, 2023 08.
Article in English | MEDLINE | ID: covidwho-2328174

ABSTRACT

BACKGROUND/PURPOSE: While current guidelines recommend the use of respiratory tract specimens for the direct detection of SARS-CoV-2 infection, saliva has recently been suggested as preferred sample type for the sensitive detection of SARS-CoV-2 B.1.1.529 (Omicron). By comparing saliva collected using buccal swabs and oro-/nasopharyngeal swabs from patients hospitalized due to COVID-19, we aimed at identifying potential differences in virus detection sensitivity between these sample types. METHODS: We compare the clinical diagnostic sensitivity of paired buccal swabs and combined oro-/nasopharyngeal swabs from hospitalized, symptomatic COVID-19 patients collected at median six days after symptom onset by real-time polymerase chain reaction (PCR) and antigen test. RESULTS: Of the tested SARS-CoV-2 positive sample pairs, 55.8% were identified as SARS-CoV-2 Omicron BA.1 and 44.2% as Omicron BA.2. Real-time PCR from buccal swabs generated significantly higher quantification cycle (Cq) values compared to those from matched combined oro-/nasopharyngeal swabs and resulted in an increased number of false-negative PCR results. Reduced diagnostic sensitivity of buccal swabs by real-time PCR was observed already at day one after symptom onset. Similarly, antigen test detection rates were reduced in buccal swabs compared to combined oro-/nasopharyngeal swabs. CONCLUSION: Our results suggest reduced clinical diagnostic sensitivity of saliva collected using buccal swabs when compared to combined oro-/nasopharyngeal swabs in the detection of SARS-CoV-2 Omicron in symptomatic individuals.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Saliva , Real-Time Polymerase Chain Reaction , Nasopharynx , Specimen Handling , COVID-19 Testing
10.
J Oral Microbiol ; 15(1): 2213106, 2023.
Article in English | MEDLINE | ID: covidwho-2326380

ABSTRACT

Background: Comparison of clinical value of RT-qPCR-based SARS-CoV-2 tests performed on saliva samples (SSs) and nasopharyngeal swab samples (NPSs) for prediction of the COVID-19 disease severity. Methods: Three paired SSs and NPSs collected every 3 days from 100 hospitalised COVID-19 patients during 2020 Jul-2021 Jan were tested by RT-qPCR for the original SARS-CoV-2 virus and compared to 150 healthy controls. Cases were divided into mild+moderate (Cohort I, N = 47) and severe disease (Cohort II, N = 53) cohorts and compared. Results: SARS-CoV-2 was detected in 65% (91/140) vs. 53% (82/156) of NPSs and 49% (68/139) vs. 48% (75/157) of SSs collected from Cohort I and II, respectively, resulting in the total respective detection rates of 58% (173/296) vs. 48% (143/296) (P = 0.017). Ct values of SSs were lower than those of NPSs (mean Ct = 28.01 vs. 30.07, P = 0.002). Although Ct values of the first SSs were significantly lower in Cohort I than in Cohort II (P = 0.04), it became negative earlier (mean 11.7 vs. 14.8 days, P = 0.005). Multivariate Cox proportional hazards regression analysis showed that Ct value ≤30 from SSs was the independent predictor for severe COVID-19 (HR = 10.06, 95% CI: 1.84-55.14, P = 0.008). Conclusion: Salivary RT-qPCR testing is suitable for SARS-CoV-2 infection control, while simple measurement of Ct values can assist in prediction of COVID-19 severity.

11.
Trends Analyt Chem ; 165: 117107, 2023 Aug.
Article in English | MEDLINE | ID: covidwho-2324531

ABSTRACT

Molecular detection of SARS-CoV-2 in gargle and saliva complements the standard analysis of nasopharyngeal swabs (NPS) specimens. Although gargle and saliva specimens can be readily obtained non-invasively, appropriate collection and processing of gargle and saliva specimens are critical to the accuracy and sensitivity of the overall analytical method. This review highlights challenges and recent advances in the treatment of gargle and saliva samples for subsequent analysis using reverse transcription polymerase chain reaction (RT-PCR) and isothermal amplification techniques. Important considerations include appropriate collection of gargle and saliva samples, on-site inactivation of viruses in the sample, preservation of viral RNA, extraction and concentration of viral RNA, removal of substances that inhibit nucleic acid amplification reactions, and the compatibility of sample treatment protocols with the subsequent nucleic acid amplification and detection techniques. The principles and approaches discussed in this review are applicable to molecular detection of other microbial pathogens.

12.
Health Sci Rep ; 6(5): e1275, 2023 May.
Article in English | MEDLINE | ID: covidwho-2323923

ABSTRACT

Background and Aims: Saliva samples are less invasive and more convenient for patients than naso- and/or oropharynx swabs (NOS). However, there is no US Food and Drug Administration-approved severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rapid antigen test kit, which can be useful in a prolonged pandemic to reduce transmission by allowing suspected individuals to self-sampling. We evaluated the performances of High sensitive AQ+ Rapid SARS-CoV-2 Antigen Test (AQ+ kit) using nasopharyngeal swabs (NPs) and saliva specimens from the same patients in laboratory conditions. Methods: The real-time reverse transcription-polymerase chain reaction (rRT-PCR) test result was used for screening the inrolled individuals and compared as the gold standard. NP and saliva samples were collected from 100 rRT-PCR positives and 100 negative individuals and tested with an AQ+ kit. Results: The AQ+ kit showed good performances in both NP and saliva samples with an overall accuracy of 98.5% and 94.0%, and sensitivity of 97.0% and 88.0%, respectively. In both cases, specificity was 100%. AQ+ kit performance with saliva was in the range of the World Health Organization recommended value. Conclusion: xOur findings indicate that the saliva specimen can be used as an alternative and less invasive to NPs for quick and reliable SARS-CoV-2 antigen detection.

13.
Revue Medicale Suisse ; 16(706):1726, 2020.
Article in French | EMBASE | ID: covidwho-2321841
14.
International Journal of Infectious Diseases ; 130(Supplement 2):S132-S133, 2023.
Article in English | EMBASE | ID: covidwho-2321761

ABSTRACT

Intro: Uptake of SARS-CoV-2 rapid antigen tests (RATs) for self-testing has been high following authorisation by the Australian Therapeutic Goods Administration (TGA). However, there are no published Australian data assessing feasibility and compliance with home-based rapid antigen testing. The aim of this study was to determine the acceptability of daily rapid antigen self-testing. Method(s): We prospectively recruited a cohort of hospital employees and students from primary and secondary school to perform daily self-testing using RATs in the home over 14 consecutive days. Participants consenting to the study were supplied with 15 Roche SARS-CoV-2 Antigen Nasal Self Tests, 3 saliva swabs for self-collection for RT-PCR and were asked to record results and answer a daily survey using a smartphone application. Finding(s): 38% (26/68) of the cohort were compliant to 14 consecutive days of testing;this was significantly higher in students (71%) than hospital employees (28%). The median number of tests performed over 14 consecutive days was 11 and time to first missed test was a median 5.5 days. The most common reasons for missing days were "I forgot" (37.5%) and "too busy" (8.9%). Ease of self- nasal swabbing, self-nasal testing. performing the test and using the app were rated as comfortable/very comfortable in over 80% of the cohort. Discussion(s): Most study participants in this Australian cohort were compliant with frequent home-based RATs. By study end most participants (93.8%) found the testing process acceptable/very acceptable. There is need for further work on the cost-effectiveness and impact of self-tested RATs under a range of specific uses and conditions. Conclusion(s): This study provided valuable information on acceptability and feasibility of regular home-based testing which could be applied to other diseases. Ongoing community engagement with clear information on RATs including accuracy and use cases is important for decision-making and addressing concerns, particularly for linguistically diverse peoples.Copyright © 2023

15.
17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022 ; 2022.
Article in English | Scopus | ID: covidwho-2326105

ABSTRACT

In the context of the Corona pandemic the investigation of aerosol spreading is utmost important as the virus is transported by the aerosol particles exhaled by an infected person. Thus, a new aerosol generation and detection system is set up and validated. The system consists of an aerosol source generating a particle size distribution mimicking typical human exhalation with particles sizes between 0.3-2.5 µm and an array of Sensirion SPS30 particulate matter sensors. An accuracy assessment of the SPS30 sensors is conducted using a TSI OPS3330, a high-precision optical particle sizer. Low deviations of ±5 % of the particle concentration measured with the SPS30 with respect to the OPS are reported for concentrations below 2'500/cm3 and +10% for particle densities up to 25'000/cm3. As an application example the system is employed in a short distance single-aisle research aircraft Dornier 728 (Do728) located at DLR Göttingen, to investigate the large-scale aerosol-spreading. With this measurement system spreading distance from an index passenger extending one seat row to the front and two seat rows to the back is determined. © 2022 17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022. All rights reserved.

16.
Int Dent J ; 2022 Nov 16.
Article in English | MEDLINE | ID: covidwho-2326164

ABSTRACT

OBJECTIVES: The COVID-19 vaccine is currently being administered worldwide to address the ongoing pandemic. Although these vaccines have proven effective in preventing severe disease, the level of immunity required to prevent respiratory mucosal infection remains less well understood. Therefore, it is desirable to develop a noninvasive screening strategy such as oral fluid to monitor secreted antibodies longitudinally as potential surrogates of mucosal immunity. METHODS: We evaluated the anti-spike protein antibodies in gingival crevicular fluid (GCF) and saliva and compared them to immune responses in the blood of 50 healthy health care workers following 2 doses of intramuscular Pfizer/BioNTech-BNT162b2 vaccine. RESULTS: The antibodies to SARS-CoV-2 spike and subdomain proteins (RBD, S1, S2, and NTD) were significantly higher in serum than oral fluids but showed a greater detection rate and higher median titres in GCF than saliva. For all tested SARS-CoV-2 antigens, IgG in GCF (as opposed to saliva) showed a more significant and stronger correlation with IgG in serum. Serum-neutralising antibodies (Nab) titres also displayed a significant and stronger correlation with anti-spike protein and their subdomains in GCF than saliva. Interestingly, the time post-second dose of vaccine and sex had a similar influence on IgG in serum and GCF. However, interferon (IFN)-γ-producing T-cell responses showed no association with SARS-Cov-2 IgG antibodies in serum, GCF, or saliva and neutralisation antibodies in serum. The correlation matrix of all measured parameters grouped serum and GCF IgG parameters separately from salivary IgG parameters indicating that GCF better represents the humoural response in serum than saliva. CONCLUSIONS: Within limitations, we propose that GCF could be a less invasive alternative to serum and more appropriate than saliva to detect antibody responses by current COVID-19 vaccines if the GCF collection procedure could be standardised. Further research is needed to investigate the suitability of GCF for community immune surveillance for vaccines.

17.
Mol Cell Biochem ; 2023 May 13.
Article in English | MEDLINE | ID: covidwho-2320907

ABSTRACT

Saliva has emerged as a promising noninvasive biofluid for the diagnosis of oral and systemic diseases, including viral infections. During the coronavirus disease 2019 (COVID-19) pandemic, a growing number of studies focused on saliva-based detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Taking advantage of the WoS core collection (WoSCC) and CiteSpace, we retrieved 1021 articles related to saliva-based detection of SARS-CoV-2 and conducted a comprehensive bibliometric analysis. We analyzed countries, institutions, authors, cited authors, and cited journals to summarize their contribution and influence and analyzed keywords to explore research hotspots and trends. From 2020 to 2021, research focused on viral transmission via saliva and verification of saliva as a reliable specimen, whereas from 2021 to the present, the focus of research has switched to saliva-based biosensors for SARS-CoV-2 detection. By far, saliva has been verified as a reliable specimen for SARS-CoV-2 detection, although a standardized procedure for saliva sampling and processing is needed. Studies on saliva-based detection of SARS-CoV-2 will promote the development of saliva-based diagnostics and biosensors for viral detection. Collectively, our findings could provide valuable information to help scientists perceive the basic knowledge landscapes on saliva-based detection of SARS-CoV-2, the past and current research hotspots, and future opportunities.

18.
Sens Actuators B Chem ; 389: 133898, 2023 Aug 15.
Article in English | MEDLINE | ID: covidwho-2318742

ABSTRACT

Equipment-free colorimetric-based lateral flow immunoassay (LFIA) is the most convenient and popular tool for various applications, including diagnostic tools requiring high sensitivity for the detection of pathogens. Thus, improvements and developments of LFIA are constantly being reported. Herein, we enriched the sensitivity of LFIA using the gold enhancement principle, emphasizing needlessly complicated apparatus, only one step for the strip test operation, and typical time incubation (15 min) process. Self-enhanced LFIA was then executed for subsequent flows by overlapping the additionally enhanced pad composed of gold ions and reducing agent on the conjugate pad and the sample pad. Self-enhanced LFIA was performed to detect SARS-CoV-2 antigens in saliva. The obtained result depicted that the achieved sensitivity was up to tenfold compared with that of conventional LFIA by visual measurements. The detection limits of self-enhanced LFIA detecting nucleocapsid protein antigens in the saliva sample was 0.50 and 0.10 ng/mL employed by naked eye detection and calibration curve-based calculation, respectively. When the proposed device was applied to 207 human saliva samples, the diagnostic performance presented a 96.10 % sensitivity and 99.23 % specificity. This self-enhanced LFIA could be implemented in large-scale production and demonstrates higher sensitivity with effortless use, which meets the requirements for point-of-care testing and on-field mass screening.

19.
Int J Mol Sci ; 24(9)2023 May 03.
Article in English | MEDLINE | ID: covidwho-2315346

ABSTRACT

Severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) may impair immune modulating host microRNAs, causing severe disease. Our objectives were to determine the salivary miRNA profile in children with SARS-CoV-2 infection at presentation and compare the expression in those with and without severe outcomes. Children <18 years with SARS-CoV-2 infection evaluated at two hospitals between March 2021 and February 2022 were prospectively enrolled. Severe outcomes included respiratory failure, shock or death. Saliva microRNAs were quantified with RNA sequencing. Data on 197 infected children (severe = 45) were analyzed. Of the known human miRNAs, 1606 (60%) were measured and compared across saliva samples. There were 43 miRNAs with ≥2-fold difference between severe and non-severe cases (adjusted p-value < 0.05). The majority (31/43) were downregulated in severe cases. The largest between-group differences involved miR-4495, miR-296-5p, miR-548ao-3p and miR-1273c. These microRNAs displayed enrichment for 32 gene ontology pathways including viral processing and transforming growth factor beta and Fc-gamma receptor signaling. In conclusion, salivary miRNA levels are perturbed in children with severe COVID-19, with the majority of miRNAs being down regulated. Further studies are required to validate and determine the utility of salivary miRNAs as biomarkers of severe COVID-19.


Subject(s)
COVID-19 , MicroRNAs , Humans , Child , Saliva/metabolism , COVID-19/genetics , COVID-19/metabolism , SARS-CoV-2/metabolism , MicroRNAs/genetics , MicroRNAs/metabolism , Signal Transduction
20.
BMC Infect Dis ; 23(1): 295, 2023 May 05.
Article in English | MEDLINE | ID: covidwho-2313341

ABSTRACT

BACKGROUND: While nasopharyngeal (NP) swabs are considered the gold standard for severe acute respiratory coronavirus 2 (SARS-CoV-2) real-time reverse transcriptase-polymerase chain reaction (RT-PCR) detection, several studies have shown that saliva is an alternative specimen for COVID-19 diagnosis and screening. METHODS: To analyze the utility of saliva for the diagnosis of COVID-19 during the circulation of the Omicron variant, participants were enrolled in an ongoing cohort designed to assess the natural history of SARS-CoV-2 infection in adults and children. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and Cohen's kappa coefficient were calculated to assess diagnostic performance. RESULTS: Overall, 818 samples were collected from 365 outpatients from January 3 to February 2, 2022. The median age was 32.8 years (range: 3-94 years). RT-PCR for SARS-CoV-2 was confirmed in 97/121 symptomatic patients (80.2%) and 62/244 (25.4%) asymptomatic patients. Substantial agreement between saliva and combined nasopharyngeal/oropharyngeal samples was observed with a Cohen's kappa value of 0.74 [95% confidence interval (CI): 0.67-0.81]. Sensitivity was 77% (95% CI: 70.9-82.2), specificity 95% (95% CI: 91.9-97), PPV 89.8% (95% CI: 83.1-94.4), NPV 87.9% (95% CI: 83.6-91.5), and accuracy 88.5% (95% CI: 85.0-91.4). Sensitivity was higher among samples collected from symptomatic children aged three years and older and adolescents [84% (95% CI: 70.5-92)] with a Cohen's kappa value of 0.63 (95% CI: 0.35-0.91). CONCLUSIONS: Saliva is a reliable fluid for detecting SARS-CoV-2, especially in symptomatic children and adolescents during the circulation of the Omicron variant.


Subject(s)
COVID-19 , Outpatients , Adolescent , Adult , Child , Humans , Saliva , COVID-19 Testing , SARS-CoV-2/genetics , COVID-19/diagnosis , Nasopharynx , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL