ABSTRACT
OBJECTIVES: This study evaluated particle spread associated with various common periodontal aerosol-generating procedures (AGPs) in simulated and clinical settings. MATERIALS AND METHODS: A simulation study visualized the aerosols, droplets, and splatter spread with and without high-volume suction (HVS, 325 L/min) during common dental AGPs, namely ultrasonic scaling, air flow prophylaxis, and implant drilling after fluorescein dye was added to the water irrigant as a tracer. Each procedure was repeated 10 times. A complementary clinical study measured the spread of contaminated particles within the dental operatory and quantified airborne protein dispersion following 10 min of ultrasonic supragingival scaling of 19 participants during routine periodontal treatment. RESULTS: The simulation study data showed that air flow produced the highest amount of splatters and the ultrasonic scaler generated the most aerosol and droplet particles at 1.2 m away from the source. The use of HVS effectively reduced 37.5-96% of splatter generation for all three dental AGPs, as well as 82-93% of aerosol and droplet particles at 1.2 m for the ultrasonic scaler and air polisher. In the clinical study, higher protein levels above background levels following ultrasonic supragingival scaling were detected in fewer than 20% of patients, indicating minimal particle spread. CONCLUSIONS: While three common periodontal AGPs produce aerosols and droplet particles up to at least 1.2 m from the source, the use of HVS is of significant benefit. Routine ultrasonic supragingival scaling produced few detectable traces of salivary protein at various sites throughout the 10-min dental operatory. CLINICAL RELEVANCE: The likelihood of aerosol spread to distant sites during common periodontal AGPs is greatly reduced by high-volume suction. Clinically, limited evidence of protein contaminants was found following routine ultrasonic scaling, suggesting that the the majority of the contamination consisits of the irrigant rather than organic matter from the oral cavity.
Subject(s)
Dental Care , Dental Scaling , Aerosols , Fluorescein , Humans , SuctionABSTRACT
Background. Droplet simulation often requires expensive and inaccessible equipment. Herein, we develop and assess a low-cost droplet simulation model using easily accessible materials, open-source software, and a smartphone-based cobalt blue light. Methods. The simulation model was developed using commercial-grade materials and fluorescein dye. A clear face shield was assessed ten times following a simulated cough using fluorescein dye. A conventional ultraviolet Woods lamp was compared to a smartphone-based cobalt blue light to detect fluorescein illumination. Results. The simulation platform and smartphone-based cobalt blue light cost $20.18. A Wilcoxon signed rank test revealed that the median droplet area of fluorescence under the UV Wood's lamp was not significantly different than that of the smartphone-based cobalt blue light (2.89 vs 2.94, P = .386). Conclusions. This simulation model is inexpensive and easily reproducible. The smartphone application may be a convenient alternative to standard ultraviolet lights. This model has great potential for use in financially restricted academic centers during the COVID-19 pandemic and beyond.
Subject(s)
COVID-19 , Smartphone , Cobalt , Coloring Agents , Fluorescein , Humans , Pandemics , Respiratory Aerosols and DropletsABSTRACT
BACKGROUND: A qualitative fit test using bitter-tasting aerosols is the commonest way to determine filtering face-piece (FFP) mask leakage. This taste test is subjective and biased by placebo. We propose a cheap, quantitative modification of the taste test by measuring the amount of fluorescein stained filter paper behind the mask using image analysis. METHODS: A bitter-tasting fluorescein solution was aerosolised during mask fit tests, with filter paper placed on masks' inner surfaces. Participants reported whether they could taste bitterness to determine taste test 'pass' or 'fail' results. Filter paper photographs were digitally analysed to quantify total fluorescence (TF). RESULTS: Fifty-six healthcare professionals were fit tested; 32 (57%) 'passed' the taste test. TF between the taste test 'pass' and 'fail' groups was significantly different (p<0.001). A cut-off (TF = 5.0 × 106 units) was determined at precision (78%) and recall (84%), resulting in 5/56 participants (9%) reclassified from 'pass' to 'fail' by the fluorescein test. Seven out of 56 (12%) reclassified from 'fail' to 'pass'. CONCLUSION: Fluorescein is detectable and sensitive at identifying FFP mask leaks. These low-cost adaptations can enhance exiting fit testing to determine 'pass' and 'fail' groups, protecting those who 'passed' the taste test but have high fluorescein leak, and reassuring those who 'failed' the taste test despite having little fluorescein leak.
Subject(s)
Occupational Exposure , Respiratory Protective Devices , Cost-Benefit Analysis , Fluorescein , Humans , Point-of-Care SystemsABSTRACT
PURPOSE: To quantify aerosol and droplets generated during noncontact tonometry (NCT) and assess the spread distance of the same. METHODOLOGY: This was an experimental study on healthy human volunteers (n=8 eyes). In an experimental setup, NCT was performed on eyes (n=8) of human volunteers under normal settings, with a single and 2 drops of lubricant. High-speed shadowgraphy, frontal lighting technique, and fluorescein analysis were used to detect the possible generation of any droplets and aerosols. Mathematical computation of the spread of the droplets was then performed. RESULTS: In a natural setting, there was no droplet or aerosol production. Minimal splatter along with droplet ejection was observed when 1 drop of lubricant was used before NCT. When 2 drops of lubricant were instilled, a significant amount of fluid ejection in the form of a sheet that broke up into multiple droplets was observed. Some of these droplets traversed back to the tonometer. Droplets ranging from 100 to 500 µm in diameter were measured. CONCLUSIONS: There was no droplet generation during NCT performed in a natural setting. However, NCT should be avoided in conditions with high-tear volume (natural or artificial) as it would lead to droplet spread and tactile contamination.
Subject(s)
Aerosols/chemistry , Betacoronavirus , Coronavirus Infections/transmission , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Intraocular Pressure/physiology , Pneumonia, Viral/transmission , Tears/chemistry , Tonometry, Ocular/instrumentation , Adolescent , Adult , COVID-19 , Environmental Monitoring , Female , Fluorescein/administration & dosage , Fluorescent Dyes/administration & dosage , Humans , Lubricant Eye Drops/administration & dosage , Male , Optical Imaging , Pandemics , SARS-CoV-2 , Young AdultABSTRACT
BACKGROUND: The intubation of patients with coronavirus disease 2019 (COVID-19) puts health care workers at risk of infection through aerosol, droplet and contact contamination. We evaluated the risk of droplet and contact contamination for health care workers using 3 intubation barrier techniques as part of a quality assurance study at our institution. METHODS: This randomized quality assurance study was completed at a tertiary academic hospital in Vancouver, British Columbia, Canada, on Apr. 4, 2020. Participants in personal protective equipment performed simulated intubations on a manikin with (a) no barrier, (b) a clear plastic sheet covering the manikin and (c) a plexiglass intubation box over the manikin, in random order. Fluorescein was ejected from inside the manikin's mouth to simulate droplet and contact spread during a standard intubation sequence. Two blinded independent assessors evaluated the location and degree of contamination on the intubator and assistant using an ultraviolet light. Contamination severity was rated in a standard fashion (0 = none; 1 = minor; 2 = major). The primary outcome was total contamination score and secondary outcomes were scores between intubator and assistant, anatomic areas contaminated and qualitative feedback on ease of intubation. RESULTS: Five participants completed this study. Total contamination score was different between the 3 groups for the intubator (p = 0.02) but not the assistant (p = 0.2). For the intubator, the total contamination score was higher when the sheet was used (median 29 [interquartile range (IQR) 25-34]) than when the box was used (median 17 [IQR 15-22]) or when no barrier was used (median 18 [IQR 13-21]). All 5 participants reported challenges during intubation using the sheet. INTERPRETATION: Use of a plastic sheet while intubating patients with COVID-19 may increase the risk of droplet and contact contamination during intubation and impede intubation. Further study should be undertaken before implementing barrier techniques in practice.
Subject(s)
COVID-19/transmission , Disease Transmission, Infectious/prevention & control , Intubation, Intratracheal/adverse effects , Personal Protective Equipment/virology , Quality Assurance, Health Care/methods , Adult , Aerosols , British Columbia/epidemiology , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/virology , Female , Fluorescein/administration & dosage , Fluorescent Dyes/administration & dosage , Health Personnel/education , Humans , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Intubation, Intratracheal/methods , Male , Manikins , Middle Aged , Outcome Assessment, Health Care , Personal Protective Equipment/statistics & numerical data , SARS-CoV-2/genetics , Simulation Training/methodsABSTRACT
OBJECTIVE: During the COVID-19 era, a reliable method for tracing aerosols and droplets generated during otolaryngology procedures is needed to accurately assess contamination risk and to develop mitigation measures. Prior studies have not investigated the reliability of different fluorescent tracers for the purpose of studying aerosols and small droplets. Objectives include (1) comparing vitamin B2, fluorescein, and a commercial fluorescent green dye in terms of particle dispersion pattern, suspension into aerosols and small droplets, and fluorescence in aerosolized form and (2) determining the utility of vitamin B2 as a fluorescent tracer coating the aerodigestive tract mucosa in otolaryngology contamination models. METHODS: Vitamin B2, fluorescein, and a commercial fluorescent dye were aerosolized using a nebulizer and passed through the nasal cavity from the trachea in a retrograde-intubated cadaveric head. In another scenario, vitamin B2 was irrigated to coat the nasal cavity and nasopharyngeal mucosa of a cadaveric head for assessment of aerosol and droplet generation from endonasal drilling. A cascade impactor was used to collect aerosols and small droplets ≤14.1 µm based on average aerodynamic diameter, and the collection chambers were visualized under UV light. RESULTS: When vitamin B2 was nebulized, aerosols ≤5.4 µm were generated and the collected particles were fluorescent. When fluorescein and the commercial water tracer dye were nebulized, aerosols ≤8.61 µm and ≤2.08 µm respectively were generated, but the collected aerosols did not appear visibly fluorescent. Endonasal drilling in the nasopharynx coated with vitamin B2 irrigation yielded aerosols ≤3.30 µm that were fluorescent under UV light. CONCLUSION: Vitamin B2's reliability as a fluorescent tracer when suspended in aerosols and small droplets ≤14.1 µm and known mucosal safety profile make it an ideal compound compared to fluorescein and commercial water-based fluorescent dyes for use as a safe fluorescent tracer in healthcare contamination models especially with human subjects.
Subject(s)
COVID-19/transmission , Disease Transmission, Infectious , Fluorescent Dyes , Models, Biological , Nasopharynx/surgery , Riboflavin , Aerosols , Cadaver , Endoscopy , Fluorescein , Humans , Models, Anatomic , Nebulizers and Vaporizers , Otolaryngology , Otorhinolaryngologic Surgical Procedures/methods , Particle Size , SARS-CoV-2Subject(s)
Aerosols/analysis , COVID-19/epidemiology , SARS-CoV-2 , Vitrectomy , Air/analysis , Animals , COVID-19/transmission , Disease Transmission, Infectious/prevention & control , Fluorescein/administration & dosage , Fluorescent Dyes/administration & dosage , Humans , Models, Animal , Nebulizers and Vaporizers , Particle Size , Photography , SheepABSTRACT
BACKGROUND: COVID-19 has become a global pandemic with a dramatic impact on healthcare systems. Concern for viral transmission necessitates the investigation of otologic procedures that use high-speed drilling instruments, including mastoidectomy, which we hypothesized to be an aerosol-generating procedure. METHODS: Mastoidectomy with a high-speed drill was simulated using fresh-frozen cadaveric heads with fluorescein solution injected into the mastoid air cells. Specimens were drilled for 1-minute durations in test conditions with and without a microscope. A barrier drape was fashioned from a commercially available drape (the OtoTent). Dispersed particulate matter was quantified in segments of an octagonal test grid measuring 60âcm in radius. RESULTS: Drilling without a microscope dispersed fluorescent particles 360 degrees, with the areas of highest density in quadrants near the surgeon and close to the surgical site. Using a microscope or varying irrigation rates did not significantly reduce particle density or percent surface area with particulate. Using the OtoTent significantly reduced particle density and percent surface area with particulate across the segments of the test grid beyond 30âcm (which marked the boundary of the OtoTent) compared with the microscope only and no microscope test conditions (Kruskall-Wallis test, pâ=â0.0066). CONCLUSIONS: Mastoidectomy with a high-speed drill is an aerosol-generating procedure, a designation that connotes the potential high risk of viral transmission and need for higher levels of personal protective equipment. A simple barrier drape significantly reduced particulate dispersion in this study and could be an effective mitigation strategy in addition to appropriate personal protective equipment.
Subject(s)
Aerosols , Coronavirus Infections/prevention & control , Mastoid/surgery , Mastoidectomy/adverse effects , Occupational Exposure/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus , COVID-19 , Cadaver , Fluorescein , Humans , Microscopy , Occupational Health , Operating Rooms , Personal Protective Equipment , SARS-CoV-2 , Surgeons , Temporal Bone/surgeryABSTRACT
BACKGROUND: The coronavirus disease (COVID-19) pandemic has raised concern of transmission of infectious organisms through aerosols formation in endonasal and transoral surgery. METHODS: Retrospective review. We introduce the negative-pressure otolaryngology viral isolation drape (NOVID) system to reduce the risk of aerosol. NOVID consists of a plastic drape suspended above the patient's head and surgical field with a smoke evacuator suction placed inside the chamber. RESULTS: Four patients underwent endonasal (4) and endo-oral surgery (1). Fluorescein was applied to the surgical field. Black light examination of fluorescein-treated operative fields revealed minimal contamination distant to the surgical field. In two prolonged cases with high-speed drilling, droplets were identified under the barrier and on the tip of the smoke evacuator. Instruments and cottonoids appeared to be a greater contributor to field contamination. CONCLUSIONS: Negative-pressure aspiration of air under a chamber barrier, which appears to successfully keep aerosol and droplet contamination to a minimum.